Finite Element Method-based Design and Simulations of Micro-cantilever Platform for Chemical and Bio-sensing Applications

被引:0
|
作者
Agarwal, R. [1 ]
Mukhiya, R. [2 ]
Sharma, R. [2 ]
Sharma, M. K. [3 ]
Goel, A. K. [3 ]
机构
[1] Birla Inst Technol & Sci, Dept Phys & Elect & Elect Engn, Pilani 333031, Rajasthan, India
[2] Cent Elect Engn Res Inst, CSIR, MEMS & Microsensors Grp, Pilani 333031, Rajasthan, India
[3] Def Res & Dev Estab, Gwalior 474002, India
关键词
Label-free; bio-sensing; bulk micromachining; micro-cantilever; piezoresistor; MICROCANTILEVERS; BIOSENSOR; SENSORS;
D O I
10.14429/dsj.66.10702
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Micro-electro-mechanical systems (MEMS)-based cantilever platform have capability for the detection of chemical and biological agents. This paper reports about the finite element method (FEM) based design and simulations of MEMS-based piezoresistor cantilever platform to be used for detection of chemical and biological toxic agents. Bulk micromachining technique is adopted for the realisation of the device structure. MEMS piezoresistive biosensing platforms are having potential for a field-based label-free detection of various types of bio-molecules. Using the MEMMECH module of CoventorWare (R) simulations are performed on the designed model of the device and it is observed that principal stress is maximum along the length (among other dimensions of the micro-cantilever) and remains almost constant for 90 per cent of the length of the micro-cantilever. The dimensions of piezoresistor are optimised and the output voltage vs. stress analysis for various lengths of the piezoresistor is performed using the MEMPZR module of the CoventorWare (R)
引用
收藏
页码:485 / 488
页数:4
相关论文
共 24 条
  • [1] A Micro-Cantilever Based Photoacoustic Detector Of Terahertz Radiation For Chemical Sensing
    Glauvitz, Nathan E.
    Coutu, Ronald A., Jr.
    Petkie, Douglas T.
    Medvedev, Ivan R.
    2013 38TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2013,
  • [2] Survey of Finite Element Method-Based Real-Time Simulations
    Marinkovic, Dragan
    Zehn, Manfred
    APPLIED SCIENCES-BASEL, 2019, 9 (14):
  • [3] MICRO-CANTILEVER BIOCHEMICAL SENSING BASED ON ROBUST FINITE-HORIZON NON-LINEAR ESTIMATION
    Wang, Xin
    Yaz, Edwin E.
    Dufour, Isabelle
    Schneider, Susan C.
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 4, PTS A AND B, 2013, : 639 - 646
  • [4] Optical readout method based on time-discrete modulation for micro-cantilever array sensing
    褚旭红
    董立泉
    赵跃进
    于晓梅
    冯韵
    Chinese Optics Letters, 2016, 14 (10) : 51 - 55
  • [5] Optical readout method based on time-discrete modulation for micro-cantilever array sensing
    Chu, Xuhong
    Dong, Liquan
    Zhao, Yuejin
    Yu, Xiaomei
    Feng, Yun
    CHINESE OPTICS LETTERS, 2016, 14 (10)
  • [6] The influence of refractive index change on a micro-cantilever bio/chemical sensor system based on optical lever read-out method
    Huang, Yuan
    Liu, Hong
    Li, Kai
    Chen, Yanyun
    Zhang, Qingchuan
    Wu, Xiaoping
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (01) : 329 - 334
  • [7] Novel Nanofluidic Cells Based on Nanowires and Nanotubes for Advanced Chemical and Bio-Sensing Applications
    Zhu, Xin-Yi
    Wang, Bo-Ran
    Gu, Yi
    Zhu, Hao
    Chen, Lin
    Sun, Qing-Qing
    NANOMATERIALS, 2021, 11 (01) : 1 - 22
  • [8] Design considerations and finite element analysis of piezoresistive cantilever for low flow sensing applications
    Bhatti, Muhammad Akram
    Li, Changxi
    Alla, Ahmed N. Abd
    DCABES 2006 Proceedings, Vols 1 and 2, 2006, : 1209 - 1213
  • [9] Silicon Nanowire based platform device for Chemical/Bio-chemical sensing applications
    Singhal, Navin
    Santosh, M.
    Prajesh, Rahul
    Bose, S. C.
    Agarwal, Ajay
    2018 IEEE SENSORS, 2018, : 1464 - 1467
  • [10] RFID-BASED WIRELESS BIO-SENSING AND MONITOR SYSTEM DESIGN WITH REPLACEABLE MICRO ARRAY PROBES
    Lin, Jium-Ming
    Lin, Cheng-Hung
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (04) : S12 - S12