Dynamic Spectrum and BP Neural Network for Non-invasive Hemoglobin Measurement

被引:8
|
作者
Wang, Huiquan [1 ]
Li, Gang [1 ]
Zhao, Zhe [1 ]
Lin, Ling [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
关键词
Dynamic Spectrum; Non-invasive Measurement; Hemoglobin; Artificial Neural Network;
D O I
10.1007/978-3-642-15615-1_9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To minimize and hopefully to eliminate the discrepancies among the individuals and the complicated conditions during non-invasive hemoglobin measuring by near-infrared spectroscopy, the Dynamic Spectrum (DS) method was applied. DS is more accurate than the traditional method in hemoglobin non-invasively measurement, which is proved by the theoretical derivation. In vivo measurements were carried out in 60 healthy volunteers, and Back Propagation Neural Network (BP-NN) was used to establish the calibration model of hemoglobin concentration against DS data, which were preprocessed by some special algorithms. The correlation coefficient of the predicted values and the true values was 0.907, which showed that DS method can be applied as a new approach to non-invasive hemoglobin analysis by near-infrared spectroscopy.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [31] MULTIFACTORIAL DEPENDENCY AND EVALUATION OF HEMOGLOBIN, DETERMINED BY NON-INVASIVE AND INVASIVE MEASUREMENT IN BLOOD DONORS
    Bohonek, M. B.
    Petras, M.
    Kricnerova, M.
    Sladkova, E.
    VOX SANGUINIS, 2013, 105 : 116 - 117
  • [32] Non-invasive measurement of hemoglobin during cesarean hysterectomy: a case series
    Butwick, A. J.
    Hilton, G.
    Riley, E. T.
    Carvalho, B.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (03) : 240 - 245
  • [33] Accurate Non-Invasive Measurement of Hemoglobin Using Occlusion Spectroscopy Sensor
    Weinstein, A.
    Herzenstein, O.
    Gabis, E.
    Carlebach, E.
    Korenberg, A.
    TRANSFUSION, 2009, 49 : 60A - 61A
  • [34] A novel device for the non-invasive measurement of free hemoglobin in blood bags
    Meinke, M
    Friebel, M
    Helfmann, J
    Notter, M
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (1-2): : 2 - 7
  • [35] A Novel Non-Invasive Technology for Hemoglobin Measurement Irrespective of the Skin Color
    Gokhale, S.
    Daggubati, V.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [36] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Hahn, Robert G.
    Wuethrich, Patrick Y.
    Zdolsek, Joachim H.
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [37] Smart Non-Invasive Hemoglobin Measurement Using Portable Embedded Technology
    Tatiparti, Padma
    Chintalapati, Usha Kumari
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2020, 16 (15) : 106 - 120
  • [38] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Robert G. Hahn
    Patrick Y. Wuethrich
    Joachim H. Zdolsek
    BMC Anesthesiology, 21
  • [39] Improving non-invasive hemoglobin measurement accuracy using nonparametric models
    Man, Jianing
    Zielinski, Martin D.
    Das, Devashish
    Wutthisirisart, Phichet
    Pasupathy, Kalyan S.
    JOURNAL OF BIOMEDICAL INFORMATICS, 2022, 126
  • [40] Non-invasive Measurement of Hemoglobin Concentration Using Magnetic Plethysmo Gram
    Bai, Rezuana J.
    Mohanasankar, S.
    Kumar, Jagadeesh, V
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 435 - 440