Discussion of FEMA P-807 for the Retrofit of Soft-Story Buildings

被引:0
|
作者
Maison, Bruce
McDonald, Brian [1 ]
McCormick, David [2 ]
Schotanus, Marko [3 ]
Buckalew, Jonathan [4 ]
机构
[1] Exponent Inc, Menlo Pk, CA 94025 USA
[2] Simpson Gumpertz & Heger Inc, San Francisco, CA 94105 USA
[3] Rutherford & Chekene, San Francisco, CA 94105 USA
[4] Nabih Youssef Associates, San Francisco, CA 94108 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The FEMA P-807 (2012) guideline titled Seismic Evaluation and Retrofit of Multi-Unit Wood-Frame Buildings with Weak First Stories is a new approach for building retrofit. It goes beyond current building codes and standards by quantifying performance in probabilistic terms. This commentary provides an overview of the P-807 approach with emphasis on key aspects that users should be aware. The objectives are to provide design professionals and building officials with a better understanding of the P-807 benefits/limitations as well as important P-807 seismic safety implications that can be discussed with building owners so informed decisions can be made about the best retrofit approach for particular projects.
引用
收藏
页码:497 / 508
页数:12
相关论文
共 45 条
  • [31] Multi-axis testing of concrete-filled steel tube columns forming ductile soft-story in multi-story buildings
    Yazdi, Hamidreza A.
    Hashemi, M. Javad
    Al-Mahaidi, Riadh
    Gad, Emad
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 183
  • [32] Development of a hybrid simulation controller for full-scale experimental investigation of seismic retrofits for soft-story woodframe buildings
    Shao, Xiaoyun
    Pang, Weichiang
    Griffith, Chelsea
    Ziaei, Ershad
    van de Lindt, John
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (08): : 1233 - 1249
  • [33] Soft story retrofit of low-rise braced buildings by equivalent moment-resisting frames
    Ebadi, Parviz
    Maghsoudi, Ahmad
    Mohamady, Hessam
    STRUCTURAL ENGINEERING AND MECHANICS, 2018, 68 (05) : 621 - 632
  • [34] Building damages during the September 19, 2017 earthquake in Mexico City and seismic retrofitting of existing first soft-story buildings
    Jara, J. M.
    Hernandez, E. J.
    Olmos, B. A.
    Martinez, G.
    ENGINEERING STRUCTURES, 2020, 209
  • [35] Classification of Soft-Story Buildings Using Deep Learning with Density Features Extracted from 3D Point Clouds
    Chen, Peng-Yu
    Wu, Zheng Yi
    Taciroglu, Ertugrul
    JOURNAL OF COMPUTING IN CIVIL ENGINEERING, 2021, 35 (03)
  • [36] Experimental Seismic Behavior of a Full-Scale Four-Story Soft-Story Wood-Frame Building with Retrofits. I: Building Design, Retrofit Methodology, and Numerical Validation
    Bahmani, Pouria
    van de Lindt, John W.
    Gershfeld, Mikhail
    Mochizuki, Gary L.
    Pryor, Steven E.
    Rammer, Douglas
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (04)
  • [37] Effect of the asymmetry level on collapse margin of torsionally stiff single-story buildings based on FEMA P695 methodology
    Makhdoom, Omid
    Aziminejad, Armin
    Zarfam, Panam
    Moghadam, Abdolreza Sarvghad
    STRUCTURES, 2022, 37 : 1042 - 1052
  • [38] Influence of story number on the Seismic Performance Factors (SPFs) of reinforced concrete frame buildings calculated using FEMA P695 procedure
    Mattovani, J. Y.
    Kristiawan, S. A.
    Supriyadi, A.
    ADVANCES IN CIVIL, ARCHITECTURAL, STRUCTURAL AND CONSTRUCTIONAL ENGINEERING, 2016, : 295 - 298
  • [39] BRB retrofit of mid-rise soft-first-story RC moment-frame buildings with masonry infill in upper stories
    Ruiz, Sonia E.
    Santos- Santiago, Marco A.
    Bojorquez, Eden
    Orellana, Miguel A.
    Valenzuela-Beltran, Federico
    Bojorquez, Juan
    Barraza, Manuel
    JOURNAL OF BUILDING ENGINEERING, 2021, 38