Chip Temperature-Based Workload Allocation for Holistic Power Minimization in Air-Cooled Data Center

被引:11
|
作者
Bai, Yan [1 ]
Gu, Lijun [1 ]
机构
[1] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
关键词
data center; energy optimization; workload allocation; chip temperature; THERMALLY AWARE; LOAD PLACEMENT; RAISED-FLOOR; OPEN-AISLE; OPTIMIZATION; EFFICIENCY; PREDICTIONS; PERFORMANCE; MANAGEMENT;
D O I
10.3390/en10122123
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Minimizing the energy consumption is a dominant problem in data center design and operation. To cope with this issue, the common approach is to optimize the data center layout and the workload distribution among servers. Previous works have mainly adopted the temperature at the server inlet as the optimization constraint. However, the inlet temperature does not properly characterize the server's thermal state. In this paper, a chip temperature-based workload allocation strategy (CTWA-MTP) is proposed to reduce the holistic power consumption in data centers. Our method adopts an abstract heat-flow model to describe the thermal environment in data centers and uses a thermal resistance model to describe the convective heat transfer of the server. The core optimizes the workload allocation with respect to the chip temperature threshold. In addition, the temperature-dependent leakage power of the server has been considered in our model. The proposed method is described as a constrained nonlinear optimization problem to find the optimal solution by a genetic algorithm (GA). We applied the method to a sample data center constructed with computational fluid dynamics (CFD) software. By comparing the simulation results with other different workload allocation strategies, the proposed method prevents the servers from overcooling and achieves a substantial energy saving by optimizing the workload allocation in an air-cooled data center.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] District Heating Mode Analysis Based on an Air-cooled Combined Heat and Power Station
    Li, Pei Feng
    Ge, Zhihua
    Yang, Zhiping
    Chen, Yuyong
    Yang, Yongping
    ENTROPY, 2014, 16 (04) : 1883 - 1901
  • [22] Optimization of modeling and temperature control of air-cooled PEMFC based on TLBO-DE
    He, Pu
    Chen, Jun-Hong
    Zhang, Chen-Zi
    Yu, Zi-Yan
    Wang, Ming-Yang
    Chen, Jun-Yu
    Song, Jia-Le
    Mu, Yu-Tong
    Gong, Kun-Ying
    Tao, Wen-Quan
    ENERGY AND AI, 2024, 18
  • [23] HEAT TRANSFER COEFFICIENT PREDICTIONS OF THE AIR-COOLED CONDENSER WITH MACHINE LEARNING BASED ON THE OPERATION BIG DATA OF THE POWER PLANT
    Chen, Kai
    Xie, Xin
    Chu, Yan
    Leng, Meng
    Zhang, Jinyi
    Xu, Zhenwei
    Huang, Feng
    Zhang, Heming
    PROCEEDINGS OF ASME 2022 HEAT TRANSFER SUMMER CONFERENCE, HT2022, 2022,
  • [24] Multi-scale modeling and fast inference for thermal environment analysis of air-cooled data center
    Cui, De 'en
    Zhou, Chaohui
    Luo, Yongqiang
    Lei, Qi
    Tian, Zhiyong
    Zhang, Shicong
    Fan, Jianhua
    Zhang, Ling
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [25] Improved Computational Fluid Dynamics Model for Open-Aisle Air-Cooled Data Center Simulations
    Abdelmaksoud, Waleed A.
    Dang, Thong Q.
    Khalifa, H. Ezzat
    Schmidt, Roger R.
    JOURNAL OF ELECTRONIC PACKAGING, 2013, 135 (03)
  • [26] Extending air-cooled data center emergency cooling duration with phase change material: An experimental study
    Gholampour, Maysam
    Zhang, Ze-Wen
    Wang, Chi-Chuan
    JOURNAL OF BUILDING ENGINEERING, 2024, 90
  • [27] Workload Balance based Dynamic Resource Allocation Model in the Cloud Data Center
    Zhang, Hairui
    Li, Minjuan
    Cui, Jianbo
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON INFORMATION SCIENCES, MACHINERY, MATERIALS AND ENERGY (ICISMME 2015), 2015, 126 : 1310 - 1314
  • [28] Minimization of Costs and Energy Consumption in a Data Center by a Workload-Based Capacity Management
    Da Costa, Georges
    Oleksiak, Ariel
    Piatek, Wojciech
    Salom, Jaume
    Siso, Laura
    ENERGY EFFICIENT DATA CENTERS (E2DC 2014), 2015, 8945 : 102 - 119
  • [29] Thermal Performance Improvement of an Air-cooled GaN-based Solid State Power Amplifier
    Oztoprak, Canberk
    Erkek, Eser
    2017 23RD INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC), 2017,
  • [30] Thermal Performance of an Air-Cooled Data Center With Raised-Floor and Non-Raised-Floor Configurations
    Srinarayana, Nagarathinam
    Fakhim, Babak
    Behnia, Masud
    Armfield, Steven W.
    HEAT TRANSFER ENGINEERING, 2014, 35 (04) : 384 - 397