Microwave techniques for electron cyclotron resonance plasma diagnostics

被引:15
|
作者
Mascali, David [1 ]
Naselli, Eugenia [1 ]
Torrisi, Giuseppe [1 ]
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Sud, Via S Sofia 62, I-95123 Catania, Italy
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2022年 / 93卷 / 03期
关键词
EXPERIMENTAL SETUP; INTERFEROMETER; DENSITY; PANDORA;
D O I
10.1063/5.0075496
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reviews the main microwave diagnostic techniques and tools adopted in electron cyclotron resonance (ECR) (and others) ion source laboratories, with a special focus on techniques and instruments developed at INFN-LNS. Along with the tools used for optimization of microwave launching (power monitors, spectral analysis, and network analyzers), this paper deals, in particular, with more recent devices on-purpose developed to perform in-plasma analysis, such as absolute density measurements and density profiles retrieval. Among these, the first example of microwave interferometry for ECR compact machines (the VESPRI interferometer at INFN-LNS) will be briefly discussed, in combination with microwave polarimetric techniques based on Faraday rotation detection. More sophisticated microwave techniques are going to be designed and are now at a numerical study stage, e.g., profilometry and imaging via inverse scattering methods (this paper will offer short theoretical bases and first numerical results on 1D profilometry). In the end, the relevance about the implications and interplays of microwave techniques in multidiagnostic systems (microwave, optical, and x-ray domains) will be commented, with a special focus on time resolved microwave measurements and advanced signal processing via wavelet transform, useful for characterization of plasma instabilities. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Microwave to plasma coupling in electron cyclotron resonance and microwave ion sources (invited)
    Celona, L.
    Gammino, S.
    Ciavola, G.
    Maimone, F.
    Mascali, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [22] Effect of discharge microwave frequency on electron temperature of electron cyclotron resonance plasma
    Kawai, Y
    Suzuki, T
    Saburi, T
    Fujii, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03): : 1666 - 1667
  • [23] ELONGATED MICROWAVE ELECTRON-CYCLOTRON RESONANCE HEATING PLASMA SOURCE
    GEISLER, M
    KIESER, J
    RAUCHLE, E
    WILHELM, R
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (02): : 908 - 915
  • [25] Plasma breakdown diagnostics with the biased disc of electron cyclotron resonance ion source
    Tarvainen, O.
    Ropponen, T.
    Toivanen, V.
    Arje, J.
    Koivisto, H.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2009, 18 (03):
  • [26] Diagnostics of plasma decay and afterglow transient of an electron cyclotron resonance ion source
    Tarvainen, O.
    Ropponen, T.
    Toivanen, V.
    Kalvas, T.
    Arje, J.
    Koivisto, H.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2010, 19 (04):
  • [28] Characteristics of an electron beam extracted from a microwave electron cyclotron resonance plasma cathode
    Li, Liang
    Liu, Yifei
    Chen, Longwei
    Wang, Gong
    Liu, Ming
    Ren, Zhaoxing
    Zhao, Ying
    Liu, Bingshan
    Zhao, Guangheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (08):
  • [29] DIAGNOSTIC-TECHNIQUES FOR PLASMA STABILITY IN ELECTRON-CYCLOTRON RESONANCE PLASMA PROCESSING
    SHUFFLEBOTHAM, PK
    THOMSON, DJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (05): : 3713 - 3719
  • [30] DEPENDENCE OF ELECTRON-CYCLOTRON RESONANCE PLASMA CHARACTERISTICS ON INTRODUCED MICROWAVE CONDITIONS
    SAMUKAWA, S
    NAKAMURA, T
    ISHITANI, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1992, 31 (5A): : L594 - L596