A sensitive and specific luminescence method for the determination of Fexofenadine (FEX), in pharmaceutical formulations is reported. The method is based on the sensitization of terbium (Tb3+) by complex formation with FEX. The luminescence signal for Tb-FEX complex is greatly enhanced by the addition of triethylamine (ET3N) and zinc nitrate in methanol solution. Monitoring of the signal is accomplished when the instrument is in the phosphorescence mode with the excitation and emission wavelengths set at lambda(ex)= 220 nm and lambda(em)= 550 nm respectively. Optimum conditions for the formation of the complex in methanol were 2.25 x 10(-6) M of Tb3+, 5.00 x 10(-6) M of Et3N and Zn2+ which allows for the determination of 10-800 ppb of FEX in the batch mode with a detection limit of 0.3 ppb. The proposed method was successfully applied for the determination of FEX in pharmaceutical formulations. (C) 2015 The Authors. Published by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:2457 / 2463
页数:7
相关论文
共 50 条
  • [31] Spectrofluorimetric Determination of Etodolac, Moxepril HCl and Fexofenadine HCl Using Europium Sensitized Fluorescence in Bulk and Pharmaceutical Preparations
    Abd El-Hay, Soad S.
    Colyer, Christa L.
    Hassan, Wafaa S.
    Shalaby, Abdalla
    JOURNAL OF FLUORESCENCE, 2012, 22 (01) : 247 - 252
  • [32] LUMINESCENCE DETERMINATION OF TERBIUM IN DYSPROSIUM OXIDE
    SHTENKE, LD
    ANTONOV, AV
    INDUSTRIAL LABORATORY, 1978, 44 (04): : 457 - 458
  • [33] Luminescence determination of terbium with dehydracetic acid
    Bel'tyukova, SV
    Denisenko, ET
    Egorova, AV
    Zheltvai, II
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (09) : 813 - 815
  • [34] A sequential injection method for the determination of piroxicam in pharmaceutical formulations using europium sensitized fluorescence
    Al-Kindy, SMZ
    Al-Wishahi, A
    Suliman, FEO
    TALANTA, 2004, 64 (05) : 1343 - 1350
  • [35] APPLICATION OF SDS MICELLES AS CARRIERS FOR RELIABLE DETERMINATION OF FEXOFENADINE AND ITS IMPURITIES IN BULK AND PHARMACEUTICAL FORMULATIONS BY CAPILLARY MICELLAR ELCETROPHORESIS
    Javid, Farin Sattary
    Shafaati, Alireza
    Zarghi, Afshin
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (01) : 112 - 121
  • [36] Determination of Mizolastine in pharmaceutical formulations
    Sreelakshmi, A.
    Rao, G. Devala
    Babu, G. Sudhakara Sai
    ORIENTAL JOURNAL OF CHEMISTRY, 2010, 26 (01) : 239 - 242
  • [37] Determination of carbamazepine in pharmaceutical formulations
    da Silva Solon, Lilian Grace
    Maia de Oliveira, Ana Isabel
    Bernardo Guerra, Gerlane Coelho
    Lira Soares, Luiz Alberto
    de Araujo, Aurigena Antunes
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 46 (03) : 509 - 513
  • [38] Determination of lomefloxacin by terbium sensitized chemiluminescence method
    Nie, Li-Hua
    Zhao, Hui-Chun
    Wang, Xu
    Yi, Lin
    Lu, Yan
    Jin, Lin-Pei
    Ma, Hui-Min
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (7-8) : 1187 - 1190
  • [39] Validation of UV spectrophotometric method for fexofenadine hydrochloride in pharmaceutical formulations and comparison with HPLC
    Breier, A. R.
    Steppe, M.
    Schapoval, E. E. S.
    ANALYTICAL LETTERS, 2007, 40 (12) : 2329 - 2337
  • [40] Study on Terbium Sensitized Luminescence Properties of Catecholamine and Its Application
    Lian Ning
    Zhang Ming
    Zhang Ya-heng
    He Xiang-hong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (11) : 3487 - 3492