PERFORMANCE OF ADD-ON HEAT PUMP WATER HEATER (HPWH) SYSTEMS AND THEIR IMPACTS ON ELECTRIC UTILITY LOADS

被引:0
|
作者
Sharaf-Eldeen, Yahya I. [1 ]
Muccio, Craig V.
Gay, Eric [1 ]
机构
[1] Florida Inst Technol, Melbourne, FL 32901 USA
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work involves measurements, analyses, and evaluations of the performance of add-on, Heat Pump Water Heater (HPWH) systems in residential and small commercial applications. Two air-source Heat Pump (HP) systems rated at 7,000- and 12,000-BTU (2.051- and 3.517-kWh), were utilized in this work. The two HPs were retrofitted to two 50-gallon (189.3 liters) electric-resistance storage water-heaters with their electric heating elements removed. A third, standard electric water-heater (EWH), was used for comparison. The testing set-up was fully instrumented for measurements of pertinent parameters, including inlet and outlet water temperatures, inlet and outlet air temperatures of the HPs, temperature and humidity of the air in the surrounding space, volume of water draws out of the storage heater tanks, as well as electric energy consumptions of the systems Several performance measures were used in this work, including the Coefficient of Performance (COP), which is a measure of the instantaneous energy output in comparison with the energy input; Energy Factor (EF), which is an average measure of the COP taken over extended periods of time; and the First Hour Rating (FHR), which is a measure of the maximum volume of hot water that a storage type water-heater can supply to a residence within an hour. The results obtained clearly indicate that, HPWH systems are much more efficient as compared to standard EWHs. While the average value of the EF for a standard EWH is close to 1.0, the HPWH systems yield EFs averaging more than 2.00, resulting in annual energy savings averaging more than 50%. The results also showed that, HPWH systems are effective at reducing utility peak demand-loads, in addition to providing substantial cost savings to consumers.
引用
收藏
页码:439 / 445
页数:7
相关论文
共 50 条
  • [41] Performance analysis of solar water heater combined with heat pump using refrigerant mixture
    Nuntaphan, Atipoang
    Chansena, Choosak
    Kiatsiriroat, Tanongkiat
    APPLIED ENERGY, 2009, 86 (05) : 748 - 756
  • [42] Evaluation of energy saving performance of residential SOFC CGS with heat pump water heater
    Inui Y.
    Tanaka T.
    Hirayama S.
    Ito D.
    Inui, Yoshitaka (inui.y@e.usp.ac.jp), 2018, Institute of Electrical Engineers of Japan (138) : 255 - 264
  • [43] Performance of a solar integrated heat pump air-conditioner, water heater and dryer
    Hawlader, M.N.A.
    Shaochun, Ye
    International Journal of Ambient Energy, 2008, 29 (04): : 189 - 196
  • [44] EXPERIMENTAL STUDY ON THE OPERATING PERFORMANCE OF A HEAT PUMP WATER HEATER WITH R417A
    Jiang, K.
    Liu, Y.
    Wang, F.
    Li, G. Y.
    Wang, X.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 595 - 601
  • [45] Performance optimization of an air source heat pump water heater using mathematical modelling
    Tangwe, Stephen
    Simon, Michael
    Meyer, Edson L.
    Mwampheli, Sampson
    Makaka, Golden
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2015, 26 (01) : 96 - 105
  • [46] Performance assessment of an air source heat pump water heater from exergy aspect
    Ozturk, M. Mete
    Dogan, Bahadir
    Erbay, L. Berrin
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 42
  • [47] Experimental Study of the Performance of a New Developed Heat Pump Water Heater with Frozen Evaporator
    Guo, Xiaochao
    Ma, Zhixian
    Ma, Liangdong
    Zhang, Jili
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1600 - 1605
  • [48] Experimental investigation on system performance of an instant heat pump water heater with combined condenser
    Ju, Fujun
    Mu, Zhenzhen
    Liu, Hongtao
    Fan, Xiaowei
    Hou, Qianlei
    Hou, Lihao
    Liu, Qinglei
    Liu, Wenbo
    Zheng, Huifan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 53
  • [49] Experimental performance analysis of ejector heat pump water heater under transient conditions
    Direk, Mehmet
    Iskan, Uemit
    Ugudur, Batuhan
    Kahraman, Mahmut Cuneyt
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (05) : 523 - 532
  • [50] Performance Study of Zeotropic Refrigerant Mixtures in an Air Source Heat Pump Water Heater
    Zhang, Chao
    Liu, Ze-Hua
    Tang, Xiao-Wei
    Zhou, Jian
    International Conference on Mechanics, Building Material and Civil Engineering (MBMCE 2015), 2015, : 263 - 268