Percutaneous Left Atrial Appendage Closure Using an Occluder Device: A Single Center Experience

被引:1
|
作者
Lugtu, Isaiah C. [1 ,2 ,3 ]
Cheng, Wen-Han [1 ,2 ,4 ,5 ]
Chang, Shih-Lin [1 ,2 ,4 ,5 ]
Liu, Shin-Huei [1 ,2 ,4 ,5 ]
Lo, Li-Wei [1 ,2 ,4 ,5 ]
Chen, Shih-Ann [1 ,2 ,4 ,5 ,6 ]
机构
[1] Taipei Vet Gen Hosp, Heart Rhythm Ctr, 201,Sec 2,Shih Pai Rd, Taipei 11217, Taiwan
[2] Taipei Vet Gen Hosp, Div Cardiol, 201,Sec 2,Shih Pai Rd, Taipei 11217, Taiwan
[3] Chinese Gen Hosp & Med Ctr, Heart Inst, Manila, Philippines
[4] Natl Yang Ming Chiao Tung Univ, Inst Clin Med, Taipei, Taiwan
[5] Natl Yang Ming Chiao Tung Univ, Cardiovasc Res Inst, Taipei, Taiwan
[6] Taichung Vet Gen Hosp, Cardiovasc Ctr, Taichung, Taiwan
关键词
Contrast leak; Left atrial appendage; Occluder device; STROKE PREVENTION; FIBRILLATION; ANTICOAGULATION; OCCLUSION; CONTRAINDICATIONS; THERAPY;
D O I
10.6515/ACS.202205_38(3).20211130A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left atrial appendage (LAA) is the main source of thrombus formation, and occlusion of this structure decreases the risk of stroke in patients with atrial fibrillation. Objectives: We aimed to describe the feasibility, safety and outcomes of percutaneous LAA closure using an occluder device, and to evaluate residual LAA contrast leak detected on computed tomography (CT) imaging in patients who underwent implantation in our institution. Methods: Consecutive patients of Taipei Veterans General Hospital who underwent percutaneous implantation of an LAA occluder (LAAO) were retrospectively collected and analyzed. Results: A total of 23 patients were included with a median age of 67 years (42-87) and median CHA(2)DS(2)-VASc score of 4 (1-7). The most frequent indication for intervention was bleeding while on oral anticoagulation treatment. After a mean follow-up of 31.17 +/- 25.10 months, successful device implantation was achieved in 95.7% of the patients. There was no occurrence of death, stroke, device embolization, acute ST elevation myocardial infarction, major bleeding requiring invasive treatment or blood transfusion, inguinal hematoma or major bleeding related to antiplatelet therapy. One patient had cardiac tamponade, 1 had intra-procedural thrombus formation, 1 had impingement of mitral valve leaflet, and 1 had device-related thrombosis. Of 12 patients who underwent CT post-implantation, 6 had residual contrast leak into the LAA, one third of those who had peri-device leak. Conclusions: Percutaneous implantation of an LAAO appeared to be feasible with a low risk of major complications.
引用
收藏
页码:352 / 361
页数:10
相关论文
共 50 条
  • [41] Pericardial effusion following percutaneous left atrial appendage closure using the LAmbre device
    Yu, Yibo
    Chu, Huimin
    Wang, Binhao
    He, Bin
    Fu, Guohua
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [42] Left atrial appendage closure followed by a single anti platelet therapy: a single center experience
    Dinet, M.
    Jalal, Z.
    Iriart, X.
    Renou, P.
    Sibon, L.
    Tafer, N.
    Thambo, J. B.
    EUROPEAN HEART JOURNAL, 2015, 36 : 658 - 658
  • [43] Percutaneous left atrial appendage closure with the Watchman device: a systematic review
    Maksym, Jakub
    Grabowski, Marcin
    Mazurek, Tomasz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (01): : 18 - 29
  • [44] PERCUTANEOUS LEFT ATRIAL APPENDAGE CLOSURE IN PATIENTS WITH LEFT ATRIAL APPENDAGE THROMBUS
    Meincke, Felix
    Kreidel, Felix
    Kuck, Karl-Heinz
    Bergmann, Martin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A345 - A345
  • [45] Percutaneous left atrial appendage closure in a surgically ligated left atrial appendage
    Wong, Ivan
    Vejlstrup, Niels Grove
    Bieliauskas, Gintautas
    Sondergaard, Lars
    De Backer, Ole
    EUROINTERVENTION, 2022, 18 (02) : E183 - E184
  • [46] Left Atrial Appendage Closure: A Single Center Experience and Comparison of Two Contemporary Devices
    Figini, Filippo
    Mazzone, Patrizio
    Regazzoli, Damiano
    Porata, Giulia
    Ruparelia, Neil
    Giannini, Francesco
    Stella, Stefano
    Ancona, Francesco
    Agricola, Eustachio
    Sora, Nicoleta
    Marzi, Alessandra
    Aurelio, Andrea
    Trevisi, Nicola
    Della Bella, Paolo
    Colombo, Antonio
    Montorfano, Matteo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (04) : 763 - 772
  • [47] Percutaneous Management of Left Atrial Appendage Perforation During Device Closure
    Meier, Bernhard
    Tarbine, Sergio G.
    Costantini, Costantino R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (02) : 305 - 307
  • [48] Percutaneous left atrial appendage closure in patients with left atrial appendage thrombus
    Meincke, Felix
    Kreidel, Felix
    von Wedel, Jasper
    Schaefer, Ulrich
    Kuck, Karl-Heinz
    Bergmann, Martin W.
    EuroIntervention, 2015, 10 (10) : 1208 - 1208
  • [49] Structural failure of a left atrial appendage occluder device
    Isilak, Zafer
    Uzun, Mehmet
    Yalcin, Murat
    Kilicaslan, Fethi
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2013, 13 (05): : E25 - E26
  • [50] Editorial to "Safety and feasibility of atrial fibrillation ablation after left atrial appendage closure: A single-center experience of the left atrial appendage closure first strategy"
    Fukunaga, Masato
    JOURNAL OF ARRHYTHMIA, 2024, 40 (04) : 893 - 894