Manufacturing and Operation of the Magnetic Septa for the Slow Beam Extraction From the J-PARC 50 GeV Proton Synchrotron

被引:5
|
作者
Muto, Ryotaro [1 ]
Arakaki, Yoshitugu [4 ]
Fan, Kuanjun [4 ]
Ishii, Koji [4 ]
Kiyomichi, Akio [1 ]
Kobayashi, Hitoshi [4 ]
Matsumoto, Hiroshi [4 ]
Murasugi, Shigeru [4 ]
Nakagawa, Hidetoshi [4 ]
Odagiri, Jun-ichi [4 ]
Okamura, Katsuya [4 ]
Sakai, Izumi [2 ]
Sato, Hikaru [3 ]
Sawada, Shin'ya [1 ]
Shirakabe, Yoshihisa [1 ]
Tanaka, Kazuhiro [1 ]
Tokumoto, Shuichi [4 ]
Tomizawa, Masahito [4 ]
Yanaoka, Eiichi [4 ]
机构
[1] High Energy Accelerator Res Org KEK, Inst Particle & Nucl Studies, Hadron Beam Channel Grp, Tsukuba, Ibaraki 3050801, Japan
[2] Univ Fukui, Fukui 9108507, Japan
[3] Tsukuba Univ Technol, Fac Ind Technol, Tsukuba, Ibaraki 3058520, Japan
[4] KEK, Accelerator Lab, Tokyo, Japan
关键词
Accelerator magnets; magnetic septa; particle beam extraction;
D O I
10.1109/TASC.2010.2040255
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The magnetic septa have been developed for the slow beam extraction from the 50 GeV Proton Synchrotron to the Hadron Experimental Hall at J-PARC (Japan Proton Accelerator Research Complex). The magnetic septa consist of two thin magnetic septa, four medium thick magnetic septa and four thick magnetic septa. The typical operating current is 3000 A and the total kick angle is 77 mrad with the 30 GeV proton beam. All parts of the thin and of the medium thick septum magnets are made of inorganic materials to resist high radiation environment. The positions of the thin and medium thick septa can be aligned remotely in the horizontal range of +/- 5 mm, which enables us to minimize the beam loss at the magnetic septum section. The septa were installed in the synchrotron ring in December, 2008, after a test at KEK (High Energy Accelerator Research Organization), and were successfully operated in the beam time for the slow beam extraction in January and February, 2009, which resulted in the first 30 GeV slow extracted beam delivery to the Hadron Experimental Hall.
引用
收藏
页码:336 / 339
页数:4
相关论文
共 39 条
  • [31] Measurement of continuous degradation of a stripper foil during ths operation with 300 kW beam power in the 3-GeV RCS of J-PARC
    Saha, P. K.
    Yoshimoto, M.
    Hotchi, H.
    Harada, H.
    Okabe, K.
    Yamazaki, Y.
    Kinsho, M.
    Irie, Y.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 305 (03) : 851 - 857
  • [32] Erratum to: Measurement of continuous degradation of a stripper foil during six months operation with 300 kW beam power in the 3-GeV RCS of J-PARC
    P. K. Saha
    M. Yoshimoto
    H. Hotchi
    H. Harada
    K. Okabe
    Y. Yamazaki
    M. Kinsho
    Y. Irie
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 308 : 375 - 375
  • [33] Magnetic field measurements, 3D field calculation and heat measurements of a prototype thick septum magnet for 3 GeV rapid cycling synchrotron of J-PARC
    Watanabe, M.
    Irie, Y.
    Kamiya, J.
    Shimada, T.
    Takayanagi, T.
    Suzuki, H.
    Watanabe, Y.
    Kawakubo, T.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 1354 - 1357
  • [34] Parasitic slow extraction of extremely weak beam from a high-intensity proton rapid cycling synchrotron
    Zou, Ye
    Tang, Jingyu
    Yang, Zheng
    Jing, Hantao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 737 : 56 - 64
  • [35] Beam commissioning of two horizontal pulse steering magnets for changing injection painting area from MLF to MR in the 3-GeV RCS OF J-PARC
    Saha, P.K.
    Harada, H.
    Hayashi, N.
    Hotchi, H.
    Kinsho, M.
    Takayanagi, T.
    Tani, N.
    Irie, Y.
    Kato, S.
    IPAC 2013: Proceedings of the 4th International Particle Accelerator Conference, 2013, : 518 - 520
  • [36] How to Make Extraction Electrode Current Lower than Beam and Corresponding Beam Qualities in J-PARC Cesiated RF-Driven H- Ion Source 66 mA Operation
    Ueno, A.
    Ohkoshi, K.
    Ikegami, K.
    Takagi, A.
    Shinto, K.
    Oguri, H.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [37] Measurement of continuous degradation of a stripper foil during six months operation with 300 kW beam power in the 3-GeV RCS of J-PARC (vol 305, pg 851, 2015)
    Saha, P. K.
    Yoshimoto, M.
    Hotchi, H.
    Harada, H.
    Okabe, K.
    Yamazaki, Y.
    Kinsho, M.
    Irie, Y.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 308 (01) : 375 - 375
  • [38] Investigation of the Efficiency of the Extraction of a 50-GeV Proton Beam from a Ring Accelerator with the Use of Silicon Crystals Bent at Various Angles
    Arkhipenko, A. A.
    Afonin, A. G.
    Baranov, V. T.
    Britvich, G. I.
    Kotov, V. I.
    Maisheev, V. A.
    Maksimov, A. V.
    Reshetnikov, S. F.
    Chepegin, V. N.
    Chesnokov, Yu. A.
    Yazynin, I. A.
    JETP LETTERS, 2008, 88 (04) : 229 - 231
  • [39] Investigation of the efficiency of the extraction of a 50-GeV proton beam from a ring accelerator with the use of silicon crystals bent at various angles
    A. A. Arkhipenko
    A. G. Afonin
    V. T. Baranov
    G. I. Britvich
    V. I. Kotov
    V. A. Maisheev
    A. V. Maksimov
    S. F. Reshetnikov
    V. N. Chepegin
    Yu. A. Chesnokov
    I. A. Yazynin
    JETP Letters, 2008, 88 : 229 - 231