Growth and Partial Discharge Characteristics of Electrical Tree in XLPE under AC-DC Composite Voltage

被引:47
|
作者
Liu, Hechen [1 ]
Liu, Yunpeng [1 ,2 ]
Li, Yanda [1 ]
Zhong, Ping [1 ]
Rui, Haoran [1 ]
机构
[1] North China Elect Power Univ, Hebei Prov Key Lab Power Transmiss Equipment Secu, Baoding City 071003, Hebei, Peoples R China
[2] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
关键词
Electrical tree; AC-DC composite voltage; AC component; XLPE; DC cable; partial discharge; REPETITIVE PULSE VOLTAGE; CABLE INSULATION; LOW-TEMPERATURE; PROPAGATION; INITIATION; MECHANISM; PMMA;
D O I
10.1109/TDEI.2017.006537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The growth characteristics of electrical trees under DC and AC voltages are quite different. In order to investigate the influences of AC component in HVDC cable system on the electrical tree properties, the growth and discharge characteristics of electrical trees under AC-DC composite voltages were studied in this paper. The results showed that the AC component greatly accelerated the developing process of the electrical trees. The influences of the positive and negative DC bias voltages on the electrical tree growth properties were quite different. The growth rate under negative DC bias voltage was similar to that under pure AC voltage and pine-branch type electrical trees were more likely to form. In contrast, the growth rate of the electrical tree increased with the increase of the positive DC bias voltage and it was much faster than the negative DC biased one. More branch-like electrical trees would form under positive DC bias voltage. When the AC component decreased, the developing process of the electrical tree was fairly tough and it was easy to form bush-like electrical trees, which were the typical conducive electrical trees with fairly small discharges. Under the positive DC bias voltage, there was a fast re-growth process of electrical tree after the bush tree formed, and the positive DC bias voltage could promote the coming of the re-growth process. However, the detected partial discharge during this process was quite small. The test results indicated that it may pose a great threat to the safety of the cable insulation if there is a large AC component in the HVDC cable system.
引用
收藏
页码:2282 / 2290
页数:9
相关论文
共 50 条
  • [11] Partial Discharge Characteristics of Typical Defects in XLPE Cable Under DC Voltage
    Du H.
    Guan H.
    Chen X.
    Hou S.
    Yang M.
    Wang X.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 555 - 563
  • [12] Simulation Research on the Discharge Characteristics of Converter Transformer Paperboard Depression Under Composite AC-DC Voltage
    Liu H.
    Xue Z.
    Li S.
    Li Q.
    He D.
    Wang G.
    Wu H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (18): : 6461 - 6471
  • [13] Research of the Electrical Tree Properties in XLPE under DC-AC Composite Voltages
    Liu Y.
    Liu H.
    Li Y.
    Yu L.
    Rui H.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (03): : 601 - 608
  • [14] Partial Discharge Characteristics and Growth Stage Recognition of Electrical Tree in XLPE Insulation
    Yang, Zhuoran
    Gao, Yuan
    Deng, Jingfang
    Lv, Lixiang
    IEEE ACCESS, 2023, 11 : 145527 - 145535
  • [15] Electrical breakdown strength of 5 kV XLPE cable with imperfections under combined ac-dc voltage
    Grzybowski, S
    Fan, J
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 616 - 619
  • [16] PARTIAL DISCHARGE CHARACTERISTICS OF OIL-IMMERSED INSULATION SYSTEMS UNDER DC, COMBINED AC-DC AND DC REVERSED POLARITY VOLTAGE
    TAKAHASHI, E
    TSUTSUMI, Y
    OKUYAMA, K
    OGATA, F
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (01): : 411 - 420
  • [17] Effects of Temperature Gradient on Electrical Tree Growth and Partial Discharge in Silicone Rubber Under AC Voltage
    Du, Boxue
    Ma, Tingting
    Su, Jingang
    Tian, Meng
    Han, Tao
    Kong, Xiaoxiao
    IEEE ACCESS, 2020, 8 : 54009 - 54018
  • [18] Electrical Tree Initiation Characteristics Under DC-impulse Composite Voltages in XLPE
    Liu H.
    Li Y.
    Zhang M.
    Xu X.
    Liu Y.
    Zheng X.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (08): : 2637 - 2643
  • [19] Study on Characteristics of Partial Discharge in XLPE Cable under Damped AC Voltage at Different Frequencies
    Yu, Peixiang
    Zhang, Long
    Li, Ruipeng
    Yang, Yuqi
    Li, Hongjie
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 750 - +
  • [20] Characteristics of the Partial Discharge-induced Current along Epoxy resin film under Superimposed AC-DC Voltage
    Zhuang, Tianxin
    Gao, Xuze
    Ren, Ming
    Wang, Siyun
    Huang, Junkai
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 469 - 472