Comparison of Age-derived Lens Thickness to Optically Measured Lens Thickness in IOL Power Calculation: A Clinical Study

被引:10
|
作者
Lam, Sheridan [1 ]
机构
[1] DuPage Ophthalmol, Lombard, IL 60148 USA
关键词
OCULAR BIOMETRY; DEVICES;
D O I
10.3928/1081597X-20111209-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess whether lens thickness derived from age should be used in intraocular lens (IOL) power calculation. METHODS: Ninety-three eyes underwent optical low coherence reflectometry (OLCR) prior to cataract surgery. Lens thickness (LT) by OLCR was used to calculate the IOL power. The mean absolute refractive error (MAE) and mean refractive error (ME) were calculated. Regression analysis between age and LT was performed. The expected IOL power, MAE, and ME were calculated with two age-derived lens thickness formulae: LT=4+(age/100) and LT=3.81+(0.0119xage). RESULTS: Lens thickness by OLCR was not significantly different from that by age, but the IOL power was different. Refractive outcome was better with OLCR-based LT. Correlation between age and LT was not as linear as implied by the formulae. CONCLUSIONS: In its current form, age-derived LT should not be used in IOL power calculation. [J Refract Surg. 2012;28(2):154-155.] doi:10.3928/1081597X-20111209-01
引用
收藏
页码:154 / 155
页数:2
相关论文
共 32 条
  • [1] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [2] Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison
    Hipolito-Fernandes, Diogo
    Luis, Maria Elisa
    Serras-Pereira, Rita
    Gil, Pedro
    Maduro, Vitor
    Feijao, Joao
    Alves, Nuno
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (03) : 349 - 355
  • [3] The influence of lens power and center thickness on the intraocular pressure measured through soft lenses: A comparison of two noncontact tonometers
    Ogbuehi, Kelechi C.
    CONTACT LENS & ANTERIOR EYE, 2012, 35 (03): : 118 - 128
  • [4] Intraocular lens power calculation: Clinical comparison of 2 optical biometry devices
    Rabsilber, Tanja M.
    Jepsen, Charlotte
    Auffarth, Gerd U.
    Holzer, Mike P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02): : 230 - 234
  • [5] THE COMPUTER CALCULATION OF INTRAOCULAR-LENS POWER - A CLINICAL-STUDY
    HILLMAN, JS
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1980, 100 (APR): : 222 - 228
  • [7] Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age
    Mohamed, Ashik
    Nandyala, Sushma
    Ho, Arthur
    Manns, Fabrice
    Parel, Jean-Marie A.
    Augusteyn, Robert C.
    EXPERIMENTAL EYE RESEARCH, 2021, 209
  • [9] Comparison of Methodologies Using Estimated or Measured Values of Total Corneal Astigmatism for Toric Intraocular Lens Power Calculation
    Ferreira, Tiago B.
    Ribeiro, Paulo
    Ribeiro, Filomena J.
    O'Neill, Joao G.
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (12) : 794 - 801
  • [10] THE SELECTION OF INTRAOCULAR-LENS POWER BY CALCULATION AND BY REFERENCE TO THE REFRACTION - A CLINICAL-STUDY
    HILLMAN, JS
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1982, 102 : 495 - 497