Use of Nonmydriatic Spectral-Domain Optical Coherence Tomography for Diagnosing Diabetic Macular Edema

被引:20
|
作者
Lara Medina, Francisco Javier [1 ]
Ispa Callen, Carmen [1 ]
Rebolleda, Gema [2 ]
Munoz-Negrete, Francisco J. [2 ]
Ispa Callen, Maria J. [3 ]
Gonzalez Del Valle, Fernando [1 ]
机构
[1] Hosp Gen Mancha La Ctr, Dept Ophthalmol, Retinal Unit, E-13600 Ciudad Real, Spain
[2] Hosp Ramon & Cajal, Dept Ophthalmol, Madrid, Spain
[3] Univ Zaragoza, Dept Stat, Aragon Govt, Zaragoza, Spain
关键词
RETINAL THICKNESS; PHOTOGRAPHY; INSTRUMENTS; RETINOPATHY; OCT;
D O I
10.1016/j.ajo.2011.08.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of 3 spectral-domain (SD) optical coherence tomography (OCT) devices (Topcon 3D-1000 [Topcon]; Cirrus HD [Carl Zeiss Meditec, Inc], and Spectralis OCT [Heidelberg Engineering]) before and after mydriasis for the diagnosis of diabetic macular edema. DESIGN: Cross-sectional study. METHODS: Sixty-two eyes of 62 consecutive patients with diabetes without recent loss of vision referred for retinal control were assessed. Two scans were performed for each SD OCT instrument. Central retinal thickness was measured before and after pupil dilation. Pupil dynamic was studied using pMetrics pupillometer (iVIS Technologies), and lens opacity was measured by Pentacam densitometry (Oculus). The diagnostic accuracy of SD OCT devices was assessed by sensitivity, specificity, and area under the receiver operating characteristic curve. Logistic regression analysis was used to assess the effect of pupil size and lens opacity on the reliability of SD OCT in the acquisition of adequate images. RESULTS: The area under the receiver operating characteristic curve for the Topcon 3D OCT device was 0.84, that for the Cirrus HD OCT device was 0.93, and that for the Spectralis OCT device was 0.91. Significant differences in area under the receiver operating characteristic curve before and after pupillary dilatation were not found. Sensitivity and specificity associated with the cutoff value for the best performance were 82% and 74% for the Topcon 3D OCT device, 90% and 87% for the Cirrus HD OCT device, and 90 h and 84% for the Spectralis OCT device, respectively. The Topcon 3D OCT device had an 11.3% segmentation algorithm failure rate for the central millimeter of the fovea, and the nuclear lens density was significantly greater in these eyes than in those without failure (17.1 +/- 1.1 mm vs 10.4 +/- 0.2 mm; P < .05). CONCLUSIONS: SD OCT is a useful tool to detect and to measure diabetic macular edema without the need for pupil dilatation. (Am J Ophthalmol 2012;153:536-543. (C) 2012 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:536 / 543
页数:8
相关论文
共 50 条
  • [21] Correlation Between Visual Function and Photoreceptor Integrity in Diabetic Macular Edema: Spectral-Domain Optical Coherence Tomography
    Shen, Yinchen
    Liu, Kun
    Xu, Xun
    CURRENT EYE RESEARCH, 2016, 41 (03) : 391 - 399
  • [22] The Relationship between Foveal Ischemia and Spectral-Domain Optical Coherence Tomography Findings in Ischemic Diabetic Macular Edema
    Lee, Dong-Hoon
    Kim, Jee Taek
    Jung, Da-Woon
    Joe, Soo Geun
    Yoon, Young Hee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (02) : 1080 - 1085
  • [23] Combined Nonmydriatic Spectral-Domain Optical Coherence Tomography and Nonmydriatic Fundus Photography for the Detection of Age-Related Macular Degeneration Changes
    Salti, Haytham I.
    Antonios, Rafic S.
    Haddad, Sandra S.
    Hamam, Rola N.
    Bashshur, Ziad F.
    Ghazi, Nicola G.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (05): : 531 - 537
  • [24] Epiretinal Membranes and Incomplete Posterior Vitreous Detachment in Diabetic Macular Edema, Detected by Spectral-Domain Optical Coherence Tomography
    Ophir, Avinoam
    Martinez, Michael R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (09) : 6414 - 6420
  • [25] Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema
    Forooghian, Farzin
    Cukras, Catherine
    Meyerle, Catherine B.
    Chew, Emily Y.
    Wong, Wai T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) : 4290 - 4296
  • [26] Spectral-Domain Optical Coherence Tomography in Uveitic Macular Edema: Morphological Features and Prognostic Factors
    Iannetti, Ludovico
    Spinucci, Giovanni
    Abbouda, Alessandro
    De Geronimo, Daniele
    Tortorella, Paolo
    Accorinti, Massimo
    OPHTHALMOLOGICA, 2012, 228 (01) : 13 - 18
  • [27] En Face Spectral-Domain Optical Coherence Tomography Imaging of Outer Retinal Hard Exudates in Diabetic Macular Edema Based on Optical Coherence Tomography Patterns
    Kim, Yonguk
    Yu, Seung-Young
    Kwak, Hyung Woo
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (04): : 313 - 321
  • [28] Comparing central retinal thickness in diabetic macular edema measured by two different spectral-domain optical coherence tomography devices
    Suzuma, Kiyoshi
    Yamada, Yoshihisa
    Liu, Michi
    Tsuiki, Eiko
    Fujikawa, Azusa
    Kitaoka, Takashi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (06) : 620 - 624
  • [29] Comparing central retinal thickness in diabetic macular edema measured by two different spectral-domain optical coherence tomography devices
    Kiyoshi Suzuma
    Yoshihisa Yamada
    Michi Liu
    Eiko Tsuiki
    Azusa Fujikawa
    Takashi Kitaoka
    Japanese Journal of Ophthalmology, 2011, 55 : 620 - 624
  • [30] Refractive and visual outcomes of macular edema of prematurity as detected by handheld spectral-domain optical coherence tomography
    Wu, Jolan
    Adan, Najma
    Ohan, Masis
    Ding, Leona
    Legocki, Alex
    Gillette, Thomas
    Shariff, Ayesha
    Grant, Laura
    Tarczy-Hornoch, Kristina
    Cabrera, Michelle
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)