Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene - A 17-year follow-up report

被引:28
|
作者
Wroblewski, BM [1 ]
Siney, PD [1 ]
Fleming, PA [1 ]
机构
[1] Wrightington Hosp, John Charnley Res Inst, Wigan WN6 9EP, England
来源
关键词
D O I
10.1302/0301-620X.87B9.16265
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no femoral or acetabular component showed loosening or osteolysis.
引用
收藏
页码:1220 / 1221
页数:2
相关论文
共 50 条
  • [32] Cross-linked ultra-high-molecular weight polyethylene liner and ceramic femoral head in total hip arthroplasty: a prospective study at 5 years follow-up
    Iñigo Orradre Burusco
    Raquel Romero
    Miriam Brun
    Jose Javier López Blasco
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1711 - 1716
  • [33] Cross-linked ultra-high-molecular weight polyethylene liner and ceramic femoral head in total hip arthroplasty: a prospective study at 5 years follow-up
    Orradre Burusco, Inigo
    Romero, Raquel
    Brun, Miriam
    Lopez Blasco, Jose Javier
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (12) : 1711 - 1716
  • [34] Incidence of Osteolysis and Aseptic Loosening Following Metal-on-Highly Cross-Linked Polyethylene Hip Arthroplasty A Systematic Review of Studies with Up to 15-Year Follow-up
    Prock-Gibbs, Hannah
    Pumilia, Cyrus Anthony
    Meckmongkol, Teerin
    Lovejoy, John
    Mumith, Aadil
    Coathup, Melanie
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (08): : 728 - 740
  • [35] Thyroid Hormone Resistance: A 17-Year Follow-up Case Report
    Giusto, Cristina
    Passeri, Marina
    Sperti, Patrizia
    Nardone, Isabella
    Sellasie, Sium Wolde
    Zaccaria, Simona
    Longo, Lucia
    Lo Deserto, Pietro
    Amendola, Stefano
    Uccioli, Luigi
    ENDOCRINE METABOLIC & IMMUNE DISORDERS-DRUG TARGETS, 2024,
  • [36] FAILURES AND REOPERATIONS FOLLOWING LOW-FRICTION ARTHROPLASTY OF THE HIP - A 5-YEAR TO 15-YEAR FOLLOW-UP-STUDY
    EFTEKHAR, NS
    TZITZIKALAKIS, GI
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (211) : 65 - 78
  • [37] Uncemented total hip arthroplasty using alumina ceramic bearings at a minimum of 14 years of follow-up
    Sachiyuki Tsukada
    Motohiro Wakui
    Kazuha Kizaki
    Takuya Iseki
    Masunao Miyao
    Atsushi Tasaki
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1689 - 1695
  • [38] Do temperature variations at the bearing surface during gait affect polyethylene wear in Charnley low-friction arthroplasty of the hip? Simulator study comparing UHMWPE and highly cross-linked polyethylene
    Roussignol, X.
    Siedlecki, C.
    Duparc, F.
    Dujardin, F.
    Ould-Slimane, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (06) : 711 - 715
  • [39] Uncemented total hip arthroplasty using alumina ceramic bearings at a minimum of 14 years of follow-up
    Tsukada, Sachiyuki
    Wakui, Motohiro
    Kizaki, Kazuha
    Iseki, Takuya
    Miyao, Masunao
    Tasaki, Atsushi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (07) : 1689 - 1695
  • [40] CHARNLEY LOW FRICTION ARTHROPLASTY IN TUBERCULOSIS OF THE HIP - AN 8-YEAR TO 13-YEAR FOLLOW-UP
    KIM, YY
    KO, CU
    AHN, JY
    YOON, YS
    KWAK, BM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05): : 756 - 760