Fourier rebinning of time-of-flight PET data

被引:56
|
作者
Defrise, M [1 ]
Casey, ME
Michel, C
Conti, M
机构
[1] Vrije Univ Brussels, Dept Nucl Med, B-1090 Brussels, Belgium
[2] CPS Innovat, Knoxville, TN 37392 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 12期
关键词
D O I
10.1088/0031-9155/50/12/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper explores fast reconstruction strategies for 3D time-of-flight (TOF) positron emission tomography (PET), based on 2D data rebinning. Starting from pre-corrected 3D TOF data, a rebinning algorithm estimates for each transaxial slice the 2D TOF sinogram that would have been acquired by a single-ring scanner. The rebinned sinograms can then be reconstructed using any algorithm for 2D TOF reconstruction. We introduce TOF-FORE, an approximate rebinning algorithm obtained by extending the Fourier rebinning method for non-TOF data. In addition, we identify two partial differential equations that must be satisfied by consistent 3D TOF data, and use them to derive exact rebinning algorithms and to characterize the degree of the approximation in TOF-FORE. Numerical simulations demonstrate that TOF-FORE is more accurate than two different TOF extensions of the single-slice rebinning method, and suggest that TOF-FORE will be a valuable tool for practical TOF PET in the range of axial apertures and time resolutions typical of current scanners.
引用
收藏
页码:2749 / 2763
页数:15
相关论文
共 50 条
  • [21] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [22] Clinical impact of time-of-flight PET
    Soussan, M.
    Galas, J-L
    Ouvrier, M-J
    Pop, G.
    Neuman, A.
    Weinmann, P.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (07): : 401 - 405
  • [23] OPTIMIZATION OF DETECTORS FOR TIME-OF-FLIGHT PET
    Moszynski, Marek
    Szczesniak, Tomasz
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 59 - 64
  • [24] Recent developments in time-of-flight PET
    Vandenberghe, S.
    Mikhaylova, E.
    D'Hoe, E.
    Mollet, P.
    Karp, J. S.
    EJNMMI PHYSICS, 2016, 3 (01):
  • [25] Recent developments in time-of-flight PET
    S. Vandenberghe
    E. Mikhaylova
    E. D’Hoe
    P. Mollet
    J. S. Karp
    EJNMMI Physics, 3
  • [26] Attenuation Artifacts and Time-of-Flight PET
    Turkington, Timothy G.
    Wilson, Joshua M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2997 - +
  • [27] Time-of-flight PET data determine the attenuation sinogram up to a constant
    Defrise, Michel
    Rezaei, Ahmadreza
    Nuyts, Johan
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (04): : 885 - 899
  • [28] Data Driven Respiratory Signal Detection in PET Taking Advantage of Time-of-Flight Data
    Bertolli, Ottavia
    Arridge, Simon
    Stearns, Charles W.
    Wollenweher, Scott D.
    Hutton, Brian F.
    Thielemans, Kris
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [29] State of the art and challenges of time-of-flight PET
    Conti, Maurizio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01): : 1 - 11
  • [30] Time-of-flight precision and PET image accuracy
    Kolthammer, Jeffrey A.
    Tang, Jing
    Perkins, Amy E.
    Muzic, Raymond F., Jr.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3657 - 3660