A liquid chromatography-tandem mass spectrometric method for quantification of curcuminoids in cell medium and mouse plasma

被引:51
|
作者
Saradhi, U. V. R. Vijaya [1 ]
Ling, Yonghua [1 ]
Wang, Jiang [1 ]
Chiu, Ming [1 ]
Schwartz, Eric B. [1 ]
Fuchs, James R. [1 ]
Chan, Kenneth K. [1 ,2 ,3 ]
Liu, Zhongfa [1 ,2 ]
机构
[1] Ohio State Univ, Coll Pharm, Columbus, OH 43210 USA
[2] Ohio State Univ, Ctr Comprehens Canc, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med & Publ Hlth, Columbus, OH 43210 USA
关键词
Curcuminoids; Liquid chromatography-mass spectrometry; Cell medium; Mouse plasma; Stability; Pharmacokinetics; RAT PLASMA; ANTICANCER; TETRAHYDROCURCUMIN; QUANTITATION; COMPLEX; URINE; AGENT;
D O I
10.1016/j.jchromb.2010.08.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Curcumin and tetrahydrocurcumin (THC) have been found as potent DNMT1 inhibitors, but they suffer from low oral bioavailability and rapid metabolism in vivo. To circumvent these problems, two curcumin analogs: 1,7-bis(3,4-dimethoxyphenyl)-4,4-dimethyl-1,6-heptadiene-3,5-dione (TMC) and 1,7-bis(3,4-dimethoxyphenyl)-4-cyclohexyl-1,6-heptadiene-3,5-dione (DMCHC) have been synthesized to enhance their stability by blocking the two metabolic sites, the phenolic and C4 methylene moieties. Both compounds have shown inhibitory activity on M. Sssl similar to that of curcumin and THC (Poster, M1114, AAPS, 2009). Preclinical pharmacokinetics has yet to be performed. In this paper, a simple liquid chromatography-tandem mass spectrometric method was developed for the determination of these four curcuminoids in cell medium and mouse plasma. The method showed linearity from 1 to 1000 ng/mL with the lower limit of quantification of 1 ng/mL in cell medium, and 5 ng/mL in mouse plasma for all test curcuminoids. The within-day coefficients of variation were found to be below 15% and the accuracy was in the range of 85-115%. This method was subsequently used to evaluate their stability in these matrices and a pilot pharmacokinetics of curcumin, DMCHC and TMC in mice after an intraperitoneal (i.p.) cassette dosing of 10 mg/kg each. Curcuminoids degraded in two phases with terminal half lives of 186, 813, 724, and 2000 min for curcumin. THC, TMC, and DMCHC, respectively, in cell culture medium. In plasma, their respective half lives were 111, 232, 1202 and 3000 min. These data demonstrated that their stability is in the order curcumin < THC < TMC < DMCHC in both matrices. Following an i.p. cassette dose, both TMC and DMCHC showed the prolonged elimination half life (1.0, 1.0 h, respectively vs 0.4 h for curcumin) and an increased drug exposure as described by the area under the curve (0.64, 0.98 mu M h, respectively vs 0.4 mu M h for curcumin). Published by Elsevier B.V.
引用
收藏
页码:3045 / 3051
页数:7
相关论文
共 50 条
  • [31] Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma
    Kong, Tae Yeon
    Ji, Hye Young
    Choi, Sang-Zin
    Son, Miwon
    Lee, Hye Suk
    MASS SPECTROMETRY LETTERS, 2013, 4 (03) : 55 - 58
  • [32] Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Cangemi, Giuliana
    Barco, Sebastiano
    Bandettini, Roberto
    Castagnola, Elio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (06) : 1795 - 1798
  • [33] Bioanalytical liquid chromatography-tandem mass spectrometric assay for the quantification of the ALK inhibitors alectinib, brigatinib and lorlatinib in plasma and mouse tissue homogenates
    Sparidans, Rolf W.
    Li, Wenlong
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 161 : 136 - 143
  • [35] Liquid chromatography-tandem mass spectrometric assay for the multikinase inhibitor regorafenib in plasma
    Luethi, Dino
    Durmus, Selvi
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    Sparidans, Rolf W.
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (10) : 1366 - 1370
  • [36] Liquid chromatography-tandem mass spectrometric assay for the PARP inhibitor rucaparib in plasma
    Sparidans, Rolf W.
    Durmus, Selvi
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 626 - 629
  • [37] Liquid Chromatography-Tandem Mass Spectrometric Assay for Determination of Stavudine in Human Plasma
    Jin, Fengdan
    JOURNAL OF SPECTROSCOPY, 2014, 2014
  • [38] Determination of metformin in human plasma by liquid chromatography-tandem mass spectrometric assay
    Wang, J
    Wang, YW
    Gu, JK
    Wu, Y
    Wang, Y
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (02) : 246 - 250
  • [39] A sensitive liquid chromatography-tandem mass spectrometry method for the quantification of valacyclovir and its metabolite acyclovir in mouse and human plasma
    Shi, Jian
    Hu, Yongjun
    Smith, David E.
    Zhu, Hao-Jie
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 447 - 452
  • [40] Sensitive and reproducible liquid chromatography-tandem mass spectrometry method for quantification of sibutramine in human plasma
    Nirogi R.V.S.
    Kandikere V.
    Shukla M.
    Mudigonda K.
    Maurya S.
    Forensic Toxicology, 2007, 25 (1) : 30 - 36