Can X-ray Spectrum Imaging Replace Backscattered Electrons for Compositional Contrast in the Scanning Electron Microscope?

被引:3
|
作者
Newbury, Dale E. [1 ]
Ritchie, Nicholas W. M. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
elemental analysis; elemental mapping; energy dispersive X-ray spectrometry; scanning electron microscopy; silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS); X-ray microanalysis; X-ray spectrum imaging;
D O I
10.1002/sca.20244
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The high throughput of the silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS) enables X-ray spectrum imaging (XSI) in the scanning electron microscope to be performed in frame times of 10 100 s, the typical time needed to record a high-quality backscattered electron (BSE) image. These short-duration XSIs can reveal all elements, except H, He, and Li, present as major constituents, defined as 0.1 mass fraction (10 wt%) or higher, as well as minor constituents in the range 0.01-0.1 mass fraction, depending on the particular composition and possible interferences. Although BSEs have a greater abundance by a factor of 100 compared with characteristic X-rays, the strong compositional contrast in element-specific X-ray maps enables XSI mapping to compete with BSE imaging to reveal compositional features. Differences in the fraction of the interaction volume sampled by the BSE and X-ray signals lead to more delocalization of the X-ray signal at abrupt compositional boundaries, resulting in poorer spatial resolution. Improved resolution in X-ray elemental maps occurs for the case of a small feature composed of intermediate to high atomic number elements embedded in a matrix of lower atomic number elements. XSI imaging strongly complements BSE imaging, and the SDD-EDS technology enables an efficient combined BSE-XSI measurement strategy that maximizes the compositional information. If 10 s or more are available for the measurement of an area of interest, the analyst should always record the combined BSE-XSI information to gain the advantages of both measures of compositional contrast. SCANNING 33: 174-192, 2011. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:174 / 192
页数:19
相关论文
共 50 条
  • [31] Three-dimensional phase-contrast X-ray microtomography with scanning-imaging X-ray microscope optics
    Takeuchi, Akihisa
    Uesugi, Kentaro
    Suzuki, Yoshio
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 793 - 800
  • [32] A new type of scanning electron microscope using the coaxial backscattered electrons
    Jiang, CZ
    Morin, P
    Rosenberg, N
    MICRON, 2002, 33 (01) : 69 - 74
  • [33] Scanning X-ray microscope
    Schelokov, IA
    Roshchupkin, DV
    Irzhak, DV
    Kondakov, AS
    CRYSTALLOGRAPHY REPORTS, 2004, 49 : S170 - S173
  • [34] THE SCANNING X-RAY MICROSCOPE
    PATTEE, HH
    PHYSICAL REVIEW, 1953, 92 (02): : 541 - 541
  • [35] THE SCANNING X-RAY MICROSCOPE
    PATTEE, HH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (01) : 61 - 62
  • [36] BACKSCATTERED ELECTRON IMAGING FOR IMMUNOGOLD VIEWING BY SCANNING ELECTRON-MICROSCOPE
    NAVA, MT
    SOLIGO, D
    POZZOLI, E
    LAMBERTENGHIDELILIERS, G
    JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 70 (02) : 269 - 271
  • [37] SCANNING ELECTRON-MICROSCOPE CYTOLOGY AND CYTOCHEMISTRY BY BACKSCATTERED ELECTRON IMAGING
    BECKER, RP
    DEBRUYN, PPH
    JOURNAL OF CELL BIOLOGY, 1976, 70 (02): : A154 - A154
  • [38] Material Contrast Identification And Compositional Contrast Mapping Using Backscattered Electron Imaging
    Lagar, Jason H.
    Raborar, Mary Grace C.
    PROCEEDINGS OF THE 2013 20TH IEEE INTERNATIONAL SYMPOSIUM ON THE PHYSICAL & FAILURE ANALYSIS OF INTEGRATED CIRCUITS (IPFA 2013), 2013, : 464 - 469
  • [39] Imaging Properties and Its Improvements of Scanning/Imaging X-ray Microscope
    Takeuchi, Akihisa
    Uesugi, Kentaro
    Suzuki, Yoshio
    XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696
  • [40] Electronic contribution to secondary electron compositional contrast in the scanning electron microscope
    Castell, MR
    Perovic, DD
    Lafontaine, H
    ULTRAMICROSCOPY, 1997, 69 (04) : 279 - 287