Prediction of total corneal power from measured anterior corneal power on the IOLMaster 700 using a feedforward shallow neural network

被引:9
|
作者
Langenbucher, Achim [1 ]
Cayless, Alan [2 ]
Szentmary, Nora [3 ,4 ]
Weisensee, Johannes [1 ]
Wendelstein, Jascha [5 ]
Hoffmann, Peter [6 ]
机构
[1] Saarland Univ, Dept Expt Ophthalmol, Kirrberger Str 100 Bldg 22, D-66424 Homburg, Germany
[2] Open Univ, Sch Phys Sci, Milton Keynes, Bucks, England
[3] Saarland Univ, Dr Rolf M Schwiete Ctr Limbal Stem Cell & Aniridi, Homburg, Germany
[4] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
[5] Johannes Kepler Univ Linz, Dept Ophthalmol, Linz, Austria
[6] Augen & Laserklin Castrop Rauxel, Castrop Rauxel, Germany
关键词
biometry; corneal back surface; deep learning; feedforward multi-output network; neural network; posterior corneal astigmatism; INTRAOCULAR-LENS CALCULATION; ASTIGMATISM; CURVATURE; KERATOMETRY; ADJUSTMENT; CATARACT;
D O I
10.1111/aos.15040
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background The corneal back surface is known to add some astigmatism against-the-rule, which has to be considered in cataract surgery with toric lens implantation. The purpose of this study was to set up a deep learning algorithm which predicts the total corneal power from keratometry and biometric measures. Methods Based on a large data set of measurements with the IOLMaster 700 from two clinical centres, data from N = 21 108 eyes were included, each record containing valid data for keratometry K, total keratometry TK, axial length AL, central corneal thickness CCT, anterior chamber depth ACD, lens thickness LT and horizontal corneal diameter W2W from an individual eye. After a vector decomposition of K and TK into equivalent power (.EQ) and projections of astigmatism to the 0 degrees/90 degrees (.AST(0 degrees)) and 45 degrees/135 degrees (.AST(45 degrees)) axis, a multi-output feedforward shallow neural network was derived to predict TK from K, AL, CCT, ACD, LT, W2W and patient age. Results After some trial and error, the neural network having a Levenberg-Marquardt training function and three hidden layers (10/8/5 neurons) performed best and showed a fast convergence. The data set was split into training data (70%), validation data (15%) and test data (15%). The prediction error (predicted corneal power CPpred minus TK) of the network trained with the training and cross-validated with test data showed systematically narrower distributions for CPEQ-TKEQ, CPAST(0 degrees)-TKAST(0 degrees) and CPAST(45 degrees)-TKAST(45 degrees) compared with KEQ-TKEQ, KAST(0 degrees)-TKAST(0 degrees) and KAST(45 degrees)-TKAST(45 degrees) . There was no systematic offset in the components between CPpred and TK. Conclusion Unlike any fixed correction term, which can compensate only for a static intercept of the astigmatic components TKEQ, TKAST(0 degrees) and TKAST(45 degrees) compared with KEQ, KAST(0 degrees) and KAST(45 degrees), our trained neural network was able to reduce the variance in the prediction error significantly. This neural network could be used to account for the corneal back surface astigmatism for biometers where the corneal back surface measurement or total keratometry is not available.
引用
收藏
页码:E1080 / E1087
页数:8
相关论文
共 50 条
  • [1] Prediction of total corneal power in keratoconus using anterior surface data
    Camellin, Umberto
    Ninotta, Ivan
    Latino, Gianluigi
    Alibrandi, Angela
    Aragona, Pasquale
    Roszkowska, Anna M. M.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (03) : 274 - 280
  • [2] The Homburg-Adelaide toric IOL nomogram: How to predict corneal power vectors from preoperative IOLMaster 700 keratometry and total corneal power in toric IOL implantation
    Langenbucher, Achim
    Szentmary, Nora
    Wendelstein, Jascha
    Cayless, Alan
    Hoffmann, Peter
    Goggin, Michael
    ACTA OPHTHALMOLOGICA, 2025, 103 (01) : e19 - e30
  • [3] Prediction of corneal spherical power from corneal topography
    Smith, RJ
    Chan, WK
    Lau, K
    Maloney, RK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4275 - 4275
  • [4] ACCURACY OF TOTAL CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT TOTAL) COMPARED TO THE TOTAL CORNEAL POWER MEASURED USING 3 DIFFERENT YOMOGRAPHERS
    Alpins, Noel A. M.
    Randleman, Bradley
    Neyvas-Wallce, Anita
    Ong, James
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 51 - 51
  • [5] Corneal Endothelium Image Segmentation Using Feedforward Neural Network
    Fabijanska, Anna
    PROCEEDINGS OF THE 2017 FEDERATED CONFERENCE ON COMPUTER SCIENCE AND INFORMATION SYSTEMS (FEDCSIS), 2017, : 629 - 637
  • [6] DIFFERENCES IN OCULAR RESIDUAL ASTIGMATISM FOR MEASUREMENTS OF ANTERIOR AND TOTAL CORNEAL POWER
    Greenwell, Timothy
    Zamora-Alejo, Katherine
    Athanasiov, Paul
    Goggin, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 : 55 - 56
  • [7] Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power
    Kern, C.
    El Kaissi, L.
    Kortuem, K.
    Shajari, M.
    Vounotrypidis, E.
    Langenbucher, A.
    Priglinger, S.
    Mayer, W. J.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (02) : 345 - 350
  • [8] Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power
    C. Kern
    L. El Kaissi
    K. Kortuem
    M. Shajari
    E. Vounotrypidis
    A. Langenbucher
    S. Priglinger
    W. J. Mayer
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 345 - 350
  • [9] Analysis of differences between keratometric astigmatism and total corneal astigmatism measured by IOLMaster 700C. Yu et al.Analysis of differences between keratometric astigmatism and total corneal astigmatism
    Chunxia Yu
    Xiaoling Fang
    Jinhua Tao
    Yiping Dong
    Shenyu Ben
    Yulan Wang
    International Ophthalmology, 45 (1)
  • [10] An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power
    Yang, Zhi
    Zhou, Yanwen
    Jin, Tianru
    Li, Jingjing
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (02) : 541 - 546