Thermodynamic performance of a new type of double absorption heat transformer

被引:50
|
作者
Zhao, ZC [1 ]
Ma, YP [1 ]
Chen, JB [1 ]
机构
[1] Dalian Univ Technol, Res Inst Chem Engn, Dalian 116012, Peoples R China
关键词
double absorption heat transformer; new type of solution cycle; performance analysis;
D O I
10.1016/j.applthermaleng.2003.08.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermodynamic performance of a new type of double absorption heat transformer (DAHT) has been studied based on the thermodynamic properties of the aqueous solution of lithium bromide and the mass and energy balance for each component of the system in this paper. The solution cycle in this new type of DAHT is different from the ones reported in literatures, in which the temperature of the absorbing evaporator is not an independent variable and the degrees of freedom of the system is less than that of the DAHT with other solution cycles by one. The results show that compared with other types of DAHT this new type of DAHT has higher coefficient of performance especially when absorber temperature gets higher. The maximum coefficient of performance and the maximum gross temperature are about 0.32 and (60-100) degreesC respectively. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2407 / 2414
页数:8
相关论文
共 50 条
  • [41] A solar-assisted double absorption heat transformer: Off-design performance and optimum control strategy
    Wang, Hanzhi
    Li, Huashan
    Wang, Lingbao
    Bu, Xianbiao
    Zeng, Jie
    Xie, Ning
    Xu, Qi
    ENERGY CONVERSION AND MANAGEMENT, 2019, 196 : 614 - 622
  • [42] Performance evaluation of a new hybrid system consisting of a photovoltaic module and an absorption heat transformer for electricity production and heat upgrading
    Zhao, Qin
    Zhang, Houcheng
    Hu, Ziyang
    Hou, Shujin
    ENERGY, 2021, 216
  • [43] Performance analysis on a new multi-effect distillation combined with an open absorption heat transformer driven by waste heat
    Zhang, Xiaodong
    Hu, Dapeng
    Li, Zhiyi
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 239 - 244
  • [44] Thermodynamic analysis of vapour absorption heat transformer using environment friendly working fluids
    Murugesan, SN
    Mohammed, KP
    Saravanan, R
    Renganarayanan, S
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 177 - 182
  • [45] Research on the performance of desalination system integrated with absorption heat transformer driven by waste heat
    Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing
    100190, China
    不详
    100190, China
    Kung Cheng Je Wu Li Hsueh Pao, 7 (1387-1391):
  • [46] Performance of an absorption heat transformer using new working binary systems composed of {ionic liquid and water}
    Abumandour, EI-Shaimaa
    Mutelet, Fabrice
    Alonso, Dominique
    APPLIED THERMAL ENGINEERING, 2016, 94 : 579 - 589
  • [47] Performance analysis of ultralow grade waste heat upgrade using absorption heat transformer
    Ma, Zhiwei
    Bao, Huashan
    Roskilly, Anthony Paul
    APPLIED THERMAL ENGINEERING, 2016, 101 : 350 - 361
  • [48] Simultaneous prediction of the performance coefficients in a compact absorption heat transformer using new neural network configurations
    R. A. Conde-Gutiérrez
    D. Colorado
    P. B. Gonzalez-Flores
    A. López-Martínez
    I. Moreno-Gómez
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [49] Optimal performance of an endoreversible four-heat-reservoir absorption heat-transformer
    Qin, XY
    Chen, LG
    Sun, FR
    Wu, C
    OPEN SYSTEMS & INFORMATION DYNAMICS, 2004, 11 (02): : 147 - 159
  • [50] Simultaneous prediction of the performance coefficients in a compact absorption heat transformer using new neural network configurations
    Conde-Gutierrez, R. A.
    Colorado, D.
    Gonzalez-Flores, P. B.
    Lopez-Martinez, A.
    Moreno-Gomez, I.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (08)