A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy

被引:3
|
作者
Saenz, Daniel L. [1 ]
Astorga, Nestor Rodrigo [1 ]
Kirby, Neil [1 ]
Fakhreddine, Mohamad [1 ]
Rasmussen, Karl [1 ]
Stathakis, Sotirios [1 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth San Antonio, San Antonio, TX 78229 USA
来源
关键词
external beam radiotherapy; patient safety; quality assurance; SETUP;
D O I
10.1002/acm2.12428
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: While external beam radiotherapy treatment planning determines nearly every mechanical and dosimetric parameter of the linear accelerator (LINAC), the table coordinates in all three dimensions are generally unknown until initial patient setup at the LINAC. Knowing these parameters in advance could help verify the direction of patient shifts and prevent wrong-site errors. This study aims to determine the feasibility and accuracy of table coordinate prediction for indexed immobilization devices. Methods: A total of 303 table coordinates were predicted for patients on Varian and Elekta linear accelerators with immobilization devices including Orfit mask with baseplate, wingboard, breastboard and BodyFix. Predictions were made for all three spatial dimensions except for Body Fix setups due to the lack of a radiographically apparent indexing-related landmark. Coordinates were predicted by measuring baseline table coordinates in all dimensions at specified landmark positions. Results: Predictions were accurate within 2 cm for 86% of coordinates (71% within 1 cm). Table coordinates were predicted most accurately for head and neck patients with a base plate and the most difficult prediction was in the lateral direction for breastboard patients. Conclusions: With proper indexing, table coordinates can be predicted with reasonable accuracy. The data suggest an action of level of 2 cm with certain exceptions for specific immobilization devices and directions.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [11] Patient-specific quality assurance using machine log files analysis for stereotactic body radiation therapy (SBRT)
    Chow, Vivian U. Y.
    Kan, Monica W. K.
    Chan, Anthony T. C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 179 - 187
  • [12] A study to establish reasonable action limits for patient-specific quality assurance in intensity-modulated radiation therapy
    Both, Stefan
    Alecu, Ionut M.
    Stan, Andrada R.
    Alecu, Marius
    Ciura, Andrei
    Hansen, Jeremy M.
    Alecu, Rodica
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 1 - 8
  • [13] A deterministic algorithm for patient-specific quality assurance in online adaptive proton therapy
    Burlacu, T.
    Lathouwers, D.
    Perko, Z.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S78 - S79
  • [14] A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
    SONG Yu-lin
    Ceferino Obcemea
    Boris Mueller
    Borys Mychalczak
    ChineseJournalofBiomedicalEngineering, 2015, 24 (02) : 58 - 65
  • [15] Residual Dose Deviation Differential Histogram Analysis Using Evolutionary-Optimized Transform Parameters for Dose Distribution Warping in Patient-Specific Quality Assurance in External Beam Radiation Therapy
    Witten, Matthew
    Clancey, Owen
    2017 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION (CEC), 2017, : 1697 - 1703
  • [16] Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System
    Ding, K.
    Ji, T.
    Iordachita, I.
    Velarde, E.
    Hyatt, J.
    Wong, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3515 - 3515
  • [17] Patient-Specific Quality Assurance in Pencil Beam Scanning by 2-Dimensional Array
    Rawiwan, Nuttida
    Chatchumnan, Nichakan
    Vimolnoch, Mananchaya
    Kingkaew, Sakda
    Oonsiri, Sornjarod
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2023, 10 (02) : 105 - 110
  • [18] Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments
    Mancuso, Gordon M.
    Fontenot, Jonas D.
    Gibbons, John P.
    Parker, Brent C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4378 - 4385
  • [19] Patient-Specific Quality Assurance Techniques for RapidArc Radiotherapy
    O'Daniel, J.
    McMahon, R.
    Chang, Z.
    Yan, H.
    Sakhalkar, H.
    Das, S.
    Wu, Q.
    Yin, F.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [20] Improvement in SRS Commission and Patient-Specific Quality Assurance
    Ding, M.
    Heard, D.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06)