Comparison of rectal and axillary temperature measurements in preterm newborns

被引:12
|
作者
McCarthy, Lisa K. [1 ,2 ,3 ]
O'Donnell, Colm Patrick Finbarr [1 ,2 ,3 ]
机构
[1] Natl Matern Hosp, Dept Neonatol, Dublin D02 YH21, Ireland
[2] Natl Childrens Res Ctr, Dublin 12, Ireland
[3] Univ Coll Dublin, Dublin, Ireland
关键词
BIRTH-WEIGHT INFANTS; DELIVERY ROOM; HEAT-LOSS; AGREEMENT;
D O I
10.1136/archdischild-2020-320627
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective To compare rectal and axillary temperatures in preterm newborns on admission to the neonatal intensive care unit (NICU). Design Secondary analysis of data collected in a randomised controlled trial (RCT). Setting Maternity hospital, level 3 NICU. Patients Seventy-two newborns <31 weeks who were enrolled in the BAMBINO RCT (A randomised trial of exothermic mattresses to prevent heat loss in preterm infants at birth, ISRCTN31707342). Interventions Newborns were placed in polyethylene bags and were randomised to placement on exothermic mattresses, or not in the delivery room. All infants had rectal and axillary temperatures measured in immediate succession using a digital thermometer on NICU admission. Outcome measures Admission rectal and axillary temperatures. Results Mean (SD) gestational age was 28 (2) weeks and birth weight was 1138 (374) g. Mean rectal-axillary temperature difference was 0.1 (0.5 degrees C) (range -1.4 degrees C to +1.5 degrees C). Rectal and axillary temperatures differed by >= 0.5 degrees C in 18/72 (25%) infants; axillary temperature was higher than rectal in 6 (8%) and lower in 12 (17%). There was a positive linear relationship between rectal and axillary measurements (Pearson's correlation R=0.84). Applying the Bland-Altman technique, the width of 95% prediction interval was 1.8 degrees C (-0.8 degrees C to 1.0 degrees C) implying that rectal and axillary measurements may vary by up to 1.0 degrees C. Axillary temperature had a sensitivity of 65% when used to detect rectal hyperthermia and 100% sensitivity for hypothermia. Conclusion Paired rectal and axillary temperature measurements in preterm newborns on NICU admission vary significantly. Axillary temperature was sensitive at detecting rectal hypothermia but not hyperthermia. Axillary temperature may not be an accurate proxy for rectal temperature measurement in all preterm newborns on NICU admission.
引用
收藏
页码:F509 / F513
页数:5
相关论文
共 50 条
  • [21] Comparison of ear to rectal temperature measurements in infants and toddlers
    Loveys, AA
    Dutko-Fioravanti, I
    Eberly, SW
    Powell, KR
    CLINICAL PEDIATRICS, 1999, 38 (08) : 463 - 466
  • [22] Comparison of rectal, axillary, and forehead temperatures
    Shann, F
    Mackenzie, A
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 1996, 150 (01): : 74 - 78
  • [23] Comparison between rectal and infrared skin temperature in newborns with different birth weights
    Calzolari, F.
    Barba, G.
    Marciano, A.
    Cardilli, V.
    De Curtis, M.
    ACTA PAEDIATRICA, 2007, 96 : 97 - 97
  • [24] Comparison of axillary and inguinal body temperature to rectal temperature in healthy guinea pigs (Cavia porcellus)
    Levy, Ivana
    Allender, Matthew C.
    Keller, Krista A.
    JOURNAL OF EXOTIC PET MEDICINE, 2020, 34 (0C) : 1 - 5
  • [25] Comparison of body temperature measurements obtained with otic digital thermometer and mercury axillary and rectal thermometers in children under the age of five
    Mccoll C, Peter
    Cohen Sch, Karen
    Soto-Aguilar B, Francisca
    Caro M, Alberto
    REVISTA CHILENA DE PEDIATRIA-CHILE, 2013, 84 (03): : 293 - 299
  • [26] Rectal and axillary admission temperature in preterm infants less than 32 weeks' gestation, a prospective study
    Halabi, Shaimaa
    Almuqati, Rana
    Al Essa, Amenah
    Althubaiti, Manal
    Alshareef, Musab
    Mahlangu, Radha
    Homedi, Abdulaziz
    Alsehli, Faisal
    Alsaif, Saif
    Ali, Kamal
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [27] Comparison of infrared tympanic, non-contact infrared skin, and axillary thermometer to rectal temperature measurements in a pediatric emergency observation unit
    Berksoy, Emel Atas
    Anil, Murat
    Bicilioglu, Yuksel
    Gokalp, Gamze
    Bal, Alkan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 567 - 573
  • [28] Comparison of Temporal Artery and Axillary Temperatures in Healthy Newborns
    Haddad, Lisa
    Smith, Sarah
    Phillips, Kenneth D.
    Heidel, R. Eric
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2012, 41 (03): : 383 - 388
  • [29] RECTAL OR AXILLARY TEMPERATURE IN THE YOUNG-CHILD
    BLUMENTHAL, I
    PRACTITIONER, 1985, 229 (1408) : 851 - 851
  • [30] TAKING AN INFANTS TEMPERATURE - AXILLARY OR RECTAL THERMOMETER
    BROWN, PJ
    CHRISTMAS, BF
    FORD, RPK
    NEW ZEALAND MEDICAL JOURNAL, 1992, 105 (939) : 309 - 311