Comparison of rectal and axillary temperature measurements in preterm newborns

被引:12
|
作者
McCarthy, Lisa K. [1 ,2 ,3 ]
O'Donnell, Colm Patrick Finbarr [1 ,2 ,3 ]
机构
[1] Natl Matern Hosp, Dept Neonatol, Dublin D02 YH21, Ireland
[2] Natl Childrens Res Ctr, Dublin 12, Ireland
[3] Univ Coll Dublin, Dublin, Ireland
关键词
BIRTH-WEIGHT INFANTS; DELIVERY ROOM; HEAT-LOSS; AGREEMENT;
D O I
10.1136/archdischild-2020-320627
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective To compare rectal and axillary temperatures in preterm newborns on admission to the neonatal intensive care unit (NICU). Design Secondary analysis of data collected in a randomised controlled trial (RCT). Setting Maternity hospital, level 3 NICU. Patients Seventy-two newborns <31 weeks who were enrolled in the BAMBINO RCT (A randomised trial of exothermic mattresses to prevent heat loss in preterm infants at birth, ISRCTN31707342). Interventions Newborns were placed in polyethylene bags and were randomised to placement on exothermic mattresses, or not in the delivery room. All infants had rectal and axillary temperatures measured in immediate succession using a digital thermometer on NICU admission. Outcome measures Admission rectal and axillary temperatures. Results Mean (SD) gestational age was 28 (2) weeks and birth weight was 1138 (374) g. Mean rectal-axillary temperature difference was 0.1 (0.5 degrees C) (range -1.4 degrees C to +1.5 degrees C). Rectal and axillary temperatures differed by >= 0.5 degrees C in 18/72 (25%) infants; axillary temperature was higher than rectal in 6 (8%) and lower in 12 (17%). There was a positive linear relationship between rectal and axillary measurements (Pearson's correlation R=0.84). Applying the Bland-Altman technique, the width of 95% prediction interval was 1.8 degrees C (-0.8 degrees C to 1.0 degrees C) implying that rectal and axillary measurements may vary by up to 1.0 degrees C. Axillary temperature had a sensitivity of 65% when used to detect rectal hyperthermia and 100% sensitivity for hypothermia. Conclusion Paired rectal and axillary temperature measurements in preterm newborns on NICU admission vary significantly. Axillary temperature was sensitive at detecting rectal hypothermia but not hyperthermia. Axillary temperature may not be an accurate proxy for rectal temperature measurement in all preterm newborns on NICU admission.
引用
收藏
页码:F509 / F513
页数:5
相关论文
共 50 条
  • [1] Using axillary temperature to approximate rectal temperature in newborns
    Lantz, Bjorn
    Ottosson, Cornelia
    ACTA PAEDIATRICA, 2015, 104 (08) : 766 - 770
  • [2] Comparison of axillary, rectal and tympanic temperature measurements in children admitted with malaria
    Musumba, CO
    Griffiths, KL
    Ross, A
    Newton, CRJC
    JOURNAL OF TROPICAL PEDIATRICS, 2005, 51 (04) : 242 - 244
  • [3] Comparing Axillary and Rectal Temperature Measurements in Very Preterm Infants: A Prospective Observational Study
    Cho, Mikyoung
    Kim, Chae Young
    Lee, JungBok
    Lee, Yumi
    Park, Minhwa
    Bae, Soohyun
    Kim, Yuri
    Kim, Yongjoo
    Lee, Byong Sop
    Kim, Ellen Ai-Rhan
    Kim, Ki-Soo
    Jung, Euiseok
    NEONATOLOGY, 2021, 118 (02) : 180 - 186
  • [4] AXILLARY AND RECTAL TEMPERATURE-MEASUREMENTS IN INFANTS
    MORLEY, CJ
    HEWSON, PH
    THORNTON, AJ
    COLE, TJ
    ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (01) : 122 - 125
  • [5] AXILLARY AND RECTAL TEMPERATURE-MEASUREMENTS IN INFANTS
    MCINTYRE, J
    HULL, D
    ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (08) : 1059 - 1059
  • [6] COMPARISON OF TEMPERATURE-MEASUREMENTS BY AN AURAL INFRARED THERMOMETER WITH MEASUREMENTS BY TRADITIONAL RECTAL AND AXILLARY TECHNIQUES
    YETMAN, RJ
    COODY, DK
    WEST, MS
    MONTGOMERY, D
    BROWN, M
    JOURNAL OF PEDIATRICS, 1993, 122 (05): : 769 - 773
  • [7] Comparison of axillary with rectal and oral temperature in children
    Sohail, Shagufta
    Shama, Qurat-ul-ain
    RAWAL MEDICAL JOURNAL, 2016, 41 (01): : 57 - 60
  • [8] Comparison of the accuracy of body temperature measurements with temporal artery thermometer and axillary mercury thermometer in term newborns
    Gunawan, Markus
    Soetjiningsih
    Kardana, I. Made
    PAEDIATRICA INDONESIANA, 2010, 50 (02) : 67 - 72
  • [10] Axillary and rectal temperature measurements poorly agree in newborn infants
    Muller, P. C. E. Hissink
    van Berkel, L. H.
    de Beaufort, A. J.
    NEONATOLOGY, 2008, 94 (01) : 31 - 34