High Accuracy and Wide Temperature Measurement by Non-Contact Speckle Extensometer

被引:4
|
作者
Kobayashi, K. [1 ]
Yamaguchi, I. [1 ]
机构
[1] Toyo Seiki Seisaku Sho Ltd, Tech Dept, Tokyo, Japan
关键词
laser-speckle correlation; low- and high-temperature test; non-contact measurement; tensile test;
D O I
10.1111/j.1475-1305.2008.00550.x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A new extensometer that has been developed needs neither markings nor mechanical clips to be attached onto the specimen and is perfectly noncontacting to automatise tensile test. Separate laser beams are incident at the positions where the markings were attached in the conventional extensometer. The spots on the specimen are imaged on a separate charge-coupled device (CCD) to produce a speckle pattern, the displacement of which is detected by real-time digital speckle correlation. Each of the optical systems is installed in a separate movable probe head that is moved under feedback control to nullify the speckle displacement detected. For detecting a small amount of specimen displacement, less than a few millimetres, the optical head is fixed to output speckle displacement. A resolution of 1 mu m was attained by comparison with a linear laser encoder. A larger displacement was detected from displacement of the probe head that cancels the detected speckle displacement by feedback control of the head movement. We also conducted tensile test in a temperature chamber controlled in a range between -40 and 100 degrees C, by placing the probe heads outside a window of the chamber.
引用
收藏
页码:E98 / E103
页数:6
相关论文
共 50 条
  • [41] Design of a non-contact human body temperature measurement system
    Deng, Xiaohong
    Su, Junhong
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2021, 11761
  • [42] Non-contact temperature measurement of aluminized polymer for space applications
    Pollard, WN
    Hannas, B
    THERMOSENSE XXIV, 2002, 4710 : 666 - 677
  • [43] An automated non-contact wall temperature measurement using thermoreflectance
    Shedd, TA
    Anderson, BW
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (12) : 2483 - 2488
  • [44] NON-CONTACT TWO-DIMENSIONAL AREA TEMPERATURE MEASUREMENT
    Palka, Jiri
    ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1567 - 1568
  • [45] Optical Metrological Errors in Non-Contact Temperature Measurement Applications
    Book, A.
    CFI-CERAMIC FORUM INTERNATIONAL, 2014, 91 (10): : E16 - +
  • [46] Non-contact in vivo measurement of ocular microtremor using laser speckle correlation metrology
    Kenny, E.
    Coakley, D.
    Boyle, G.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (07) : 1229 - 1243
  • [47] Non-Contact and Real-Time Measurement of Kolsky Bar with Temporal Speckle Interferometry
    Yang, Shanwei
    Gao, Zhan
    Ruan, Haihui
    Gao, Chenjia
    Wang, Xu
    Sun, Xiang
    Wen, Xin
    APPLIED SCIENCES-BASEL, 2018, 8 (05):
  • [48] Identification of wavelength regions for non-contact temperature measurement of combustion gases at high temperatures and high pressures
    Zipf, Matthias
    Manara, Jochen
    Stark, Thomas
    Arduini, Mariacarla
    Ebert, Hans-Peter
    Hartmann, Juergen
    HIGH TEMPERATURES-HIGH PRESSURES, 2020, 49 (03) : 241 - 260
  • [49] Non-contact and contact measurement Quick Vision
    不详
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2001, 73 (04): : 423 - 423
  • [50] Non-contact laser speckle anemometry of microcirculatory bloodstream
    Golovan, O. A.
    Velichko, E. N.
    Baranov, M. A.
    Aksenov, E. T.
    2018 INTERNATIONAL CONFERENCE LASER OPTICS (ICLO 2018), 2018, : 523 - 523