Brain MRI Lesion Load at 1.5T and 3T versus Clinical Status in Multiple Sclerosis

被引:89
|
作者
Stankiewicz, James M. [1 ,2 ]
Glanz, Bonnie I. [2 ]
Healy, Brian C. [2 ]
Arora, Ashish [2 ]
Neema, Mohit [2 ]
Benedict, Ralph H. B. [3 ]
Guss, Zachary D. [2 ]
Tauhid, Shahamat [2 ]
Buckle, Guy J. [2 ]
Houtchens, Maria K. [2 ]
Khoury, Samia J. [2 ]
Weiner, Howard L. [2 ]
Guttmann, Charles R. G. [1 ,2 ]
Bakshi, Rohit [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Neurol & Radiol,Partners MS Ctr, Brookline, MA 02445 USA
[2] Harvard Univ, Sch Med, Dept Neurol, Brookline, MA 02445 USA
[3] SUNY Buffalo, Dept Neurol, Buffalo, NY 14260 USA
基金
美国国家卫生研究院;
关键词
MRI; multiple sclerosis; cognitive testing; 1; 5T; 3T; STATUS SCALE EDSS; QUALITY-OF-LIFE; COGNITIVE IMPAIRMENT; DYSFUNCTION; ATROPHY; DISABILITY; VALIDITY; BURDEN; PREDICTION; FREQUENCY;
D O I
10.1111/j.1552-6569.2009.00449.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND/PURPOSE To assess correlation between brain lesions and clinical status with 1.5T and 3T magnetic resonance imaging (MRI). METHODS Brain MRI fluid-attenuated inversion-recovery (FLAIR) sequences were performed in 32 multiple sclerosis (MS) patients. Expanded Disability Status Scale (EDSS) score (mean +/- standard deviation) was 2 +/- 2.0 (range 0-8), disease duration 9.3 +/- 8.0 (range .8-29) years. RESULTS FLAIR lesion volume (FLLV) at 3T was higher than at 1.5T (P = .01). Correlation between 1.5T FLLV and EDSS score was poor, while 3T FLLV correlated moderately and significantly (r(s) = .39, P = .03). When controlling for age and depression, correlations between FLLV and cognitive measures were significant at 1.5T for the Judgment of Line Orientation test (JLO) (r(s) = -.44, P = .05), the Symbol Digit Modalities Test (SDMT) (r(s) = -.49, P = .02), and the California Verbal Learning Test Delayed Free Recall (CVLT DR) (r(s) = -.44, P = .04). Correlations at 3T were also significant for these tests, but of greater magnitude: JLO (r(s) = -.70, P = .0005), SDMT (r(s) = -.73, P = .0001), CVLT DR (r(s) = -.061, P = .003). Additional significant correlations obtained only at 3T included the 2 second-paced auditory serial addition test (r(s) = -.55, P = .01), the Brief Visuospatial Memory Test-Delayed Free Recall (r(s) = -.56, P = .007), and the California Verbal Learning Test Total Recall (r(s) = -.42, P = .05). CONCLUSION MRI at 3T may boost sensitivity and improve validity in MS brain lesion assessment.
引用
收藏
页码:e50 / e56
页数:7
相关论文
共 50 条
  • [41] A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)
    Keihaninejad, Shiva
    Heckemann, Rolf A.
    Fagiolo, Gianlorenzo
    Symms, Mark R.
    Hajnal, Joseph V.
    Hammers, Alexander
    NEUROIMAGE, 2010, 50 (04) : 1427 - 1437
  • [42] Effects of Combining Field Strengths on Auditory Functional MRI Group Analysis: 1.5T and 3T
    Han, Kihwan
    Talavage, Thomas M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (06) : 1480 - 1488
  • [43] COMPARING BETWEEN MR SPECTROSCOPY DONE AT 1.5T AND 3T
    Tang, Phua Hwee
    Nisa, Sameema
    NEURO-ONCOLOGY, 2022, 24 : 77 - 77
  • [44] Comparison of 1.5T and 3T in assessment of suspicious breast lesions
    SK Arcot Ragupathy
    T Gagliardi
    TW Redpath
    S Flynn
    B Jagpal
    JKP Begley
    FJ Gilbert
    Breast Cancer Research, 12
  • [45] Comparison of 1.5T and 3T in assessment of suspicious breast lesions
    Ragupathy, S. K. Arcot
    Gagliardi, T.
    Redpath, T. W.
    Flynn, S.
    Jagpal, B.
    Begley, J. K. P.
    Gilbert, F. J.
    BREAST CANCER RESEARCH, 2010, 12
  • [46] PROSTATE CANCER: COMPARING THE IMAGE QUALITY OF ENDORECTAL MRI AT 1.5T WITH 3T MRI WITHOUT THE ENDORECTAL COIL
    Jia, Guang
    Shah, Zarine
    Wei, Lai
    Knopp, Michael
    JOURNAL OF UROLOGY, 2013, 189 (04): : E895 - E896
  • [47] Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners
    Sklinda, Katarzyna
    Karpowicz, Jolanta
    Stepniewski, Andrzej
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (01)
  • [48] Wireless video transmission into the MRI magnet room: implementation and evaluation at 1.5T, 3T and 7T
    Hensen, Bennet
    Kaegebein, Urte
    Gutberlet, Marcel
    Ringe, Kristina, I
    Van Dai Vo-Chieu
    Stucht, Daniel
    Speck, Oliver
    Vick, Ralf
    Wacker, Frank
    Pannicke, Enrico
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (04): : 373 - 382
  • [49] Occult Amyloid-β-Related Angiitis: Neuroimaging Findings at 1.5T, 3T, and 7T MRI
    Ozutemiz, Can
    Hussein, Haitham M.
    Ikramuddin, Salman
    Clark, H. Brent
    Charidimou, Andreas
    Streib, Christopher
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (08) : 1013 - 1018
  • [50] Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors
    Kim, Ji-hoon
    Chang, Kee-Hyun
    Na, Dong Gyu
    Song, In Chan
    Kim, Seung Ja
    Kwon, Bae Ju
    Han, Moon Hee
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (03) : 156 - 161