Sensitive voltammetric determination of baicalein at DNA Langmuir-Blodgett film modified glassy carbon electrode

被引:26
|
作者
Wang, Fei [1 ,2 ]
Zhao, Fangyuan [1 ]
Zhang, Yanzheng [1 ]
Yang, Huige [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Dept Chem, Zhengzhou 450052, Peoples R China
[2] Henan Inst Engn, Dept Mat & Chem Engn, Zhengzhou 450007, Peoples R China
基金
中国国家自然科学基金;
关键词
Baicalein; Square wave voltammetry; Langmuir-Blodgett film; DNA; CANCER CELL-LINES; SCUTELLARIAE-RADIX; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; WOGONIN; ACID; ANTIOXIDANT; FLAVONOIDS; BIOSENSOR; BEHAVIOR;
D O I
10.1016/j.talanta.2010.12.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes to modify a double stranded DNA-octadecylamine (ODA) Langmuir-Blodgett film on a glassy carbon electrode (GCE) surface to develop a voltammetric sensor for the detection of trace amounts of baicalein. The electrode was characterized by atomic force microscopy (AFM) and cyclic voltammetry (CV). Electrochemical behaviour of baicalein at the modified electrode had been investigated in pH 2.87 Britton-Robinson buffer solutions by CV and square wave voltammetry (SWV). Compared with bare GCE, the electrode presented an electrocatalytic redox for baicalein. Under the optimum conditions, the modified electrode showed a linear voltammetric response for the baicalein within a concentration range of 1.0 x 10(-8)-2.0 x 10(-6) mol L-1, and a value of 6.0 x 10(-9) mol L-1 was calculated for the detection limit. And the modified electrode exhibited an excellent immunity from epinephrine, dopamine, glucose and ascorbic acid interference. The method was also applied successfully to detect baicalein in the medicinal tablets and spiked human blood serum samples with satisfactory results. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [21] The construction of well-aligned MWCNTs-PANI Langmuir-Blodgett film modified glassy carbon electrode and its analytical application
    Wang, Lu
    Li, Yinfeng
    Wang, Qinqin
    Zou, Lina
    Ye, Baoxian
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 214 - 220
  • [22] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [23] Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Gutz, IGR
    LaScalea, MA
    ELECTROANALYSIS, 1997, 9 (02) : 110 - 114
  • [24] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [25] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [26] Sensitive voltammetric determination of neohesperidin dihydrochalcone based on SWNTs modified glassy carbon electrode
    Yang, Lingxi
    Wang, Lu
    Li, Kunjing
    Ye, Baoxian
    ANALYTICAL METHODS, 2014, 6 (23) : 9410 - 9418
  • [27] Langmuir–Blodgett film of tetraoxocalix[2]arene[2]triazine modified electrode for voltammetric determination of copper ion
    Lina Zou
    Yamin Li
    Wenjie Zhao
    Shusheng Zhang
    Baoxian Ye
    Journal of Solid State Electrochemistry, 2012, 16 : 505 - 511
  • [28] Polyfurfural film modified glassy carbon electrode for highly sensitive nifedipine determination
    Zeng, Qiang
    Wei, Tianyan
    Wang, Min
    Huang, Xinjian
    Fang, Yishan
    Wang, Lishi
    ELECTROCHIMICA ACTA, 2015, 186 : 465 - 470
  • [29] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [30] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23