Advancement of X-ray radiography using microfocus X-ray source in conjunction with amplitude grating and SOI pixel detector, SOPHIAS

被引:4
|
作者
Hosono, Ryo [1 ]
Kawabata, Tomoki [2 ]
Hayashida, Kiyoshi [2 ]
Kudo, Togo [3 ,4 ]
Ozaki, Kyosuke [3 ]
Teranishi, Nobukazu [3 ,5 ]
Hatsui, Takaki [3 ]
Hosoi, Takuji [1 ]
Watanabe, Heiji [1 ]
Shimura, Takayoshi [1 ]
机构
[1] Osaka Univ, Grad Sch Engn, Dept Mat & Life Sci, 2-1 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, 1-1 Machikaneyama Cho, Toyonaka, Osaka 5600043, Japan
[3] RIKEN, RIKEN SPring Ctr 8, 1-1-1 Kouto, Sayo, Hyogo 6795148, Japan
[4] Japan Synchrotron Radiat Res Inst JASRI, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[5] Univ Hyogo, 1-1-2 Koto, Kamigori, Hyogo 6781205, Japan
来源
OPTICS EXPRESS | 2018年 / 26卷 / 16期
基金
日本学术振兴会;
关键词
INTERFEROMETRY;
D O I
10.1364/OE.26.021044
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We show how to improve microfocus X-ray radiography by using the SOPHIAS silicon-on-insulator pixel detector in conjunction with an amplitude grating. Single-exposure multi-energy absorption and differential phase contrast imaging was performed using the single amplitude grating method. The sensitivity in differential phase contrast imaging in a two-pixel-pitch setup was enhanced by 39% in comparison with the previously reported method [F. Krejci, Rev. Sci. Instrum. 81, 113702 (2010).] by analyzing charge-sharing effects. Small-angle-scattering imaging was also possible in the two-pixel-pitch setup by counting the number of X-ray photons passing the pixel boundaries. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:21044 / 21053
页数:10
相关论文
共 50 条
  • [21] Point x-ray source using graphite nanofibers and its application to x-ray radiography
    Matsumoto, T
    Mimura, H
    APPLIED PHYSICS LETTERS, 2003, 82 (10) : 1637 - 1639
  • [22] X-ray tests of a Pixel Array Detector for coherent x-ray imaging at the Linac Coherent Light Source
    Koerner, L. J.
    Philipp, H. T.
    Hromalik, M. S.
    Tate, M. W.
    Gruner, S. M.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [23] X-ray wavefront sensing and optics metrology using a microfocus x-ray grating interferometer with electromagnetic phase stepping
    Zhao, Shuai
    Yang, Yu
    Liu, Huiting
    Huang, Ziwen
    Zhang, Lei
    Wang, Qiuping
    Wang, Keyi
    APPLIED PHYSICS LETTERS, 2022, 120 (18)
  • [24] Grating-Based X-ray Phase Imaging Using Multiline X-ray Source
    Momose, Atsushi
    Yashiro, Wataru
    Kuwabara, Hiroaki
    Kawabata, Katsuyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (07)
  • [25] HIGH SENSITIVITY RADIOGRAPHY WITH A VARIABLE MICROFOCUS X-RAY UNIT
    RIDDER, HJ
    MATERIALS EVALUATION, 1974, 32 (09) : A32 - A32
  • [26] X-RAY RADIOGRAPHY WITH X-RAY DIFFRACTION EQUIPMENT
    CLIFTON, HE
    JOURNAL OF SEDIMENTARY PETROLOGY, 1966, 36 (02): : 620 - &
  • [27] A microfocus X-ray tube based on a microstructured X-ray target
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (21-22): : 3566 - 3573
  • [28] Contrast and resolution in imaging with a microfocus x-ray source
    Pogany, A
    Gao, D
    Wilkins, SW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07): : 2774 - 2782
  • [29] A gas pixel detector for X-ray polarimetry
    Baldini, L
    Angelini, F
    Bellazzini, R
    Bitti, F
    Brez, A
    Latronico, L
    Massai, MM
    Minuti, M
    Omodei, N
    Razzano, M
    Sgro, C
    Spandre, G
    Costa, E
    Soffitta, P
    Pacciani, L
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 358 - 361
  • [30] Large surface X-ray pixel detector
    Delpierre, P
    Berar, JF
    Blanquart, L
    Boudet, N
    Breugnon, P
    Caillot, B
    Clemens, JC
    Mouget, C
    Potheau, R
    Valin, I
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 902 - 905