Quartz Crystal Microbalance coated with sol-gel-derived thin films as gas sensor for NO detection

被引:14
|
作者
Zhang, J
Hu, JQ
Zhu, FR
Gong, H
O'Shea, SJ
机构
[1] Inst Mat Res & Engn, Singapore 117602, Singapore
[2] Natl Univ Singapore, Dept Mat Sci, Singapore 119260, Singapore
来源
SENSORS | 2003年 / 3卷 / 10期
关键词
Quartz Crystal Microbalance; Indium tin oxide; gas sensor; resonant frequency;
D O I
10.3390/s31000404
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the possibilities and properties of Indium tin oxide (ITO)covered quartz crystal as a NOx toxic gas-sensor. The starting sol-gel solution was prepared by mixing indium chloride dissolved in acetylacetone and tin chloride dissolved in ethanol (0-20% by weight). The ITO thin films were deposited on the gold electrodes of quartz crystal by spin-coating technique and subsequently followed a standard photolithography to pattern the derived films to ensure all sensors with the same sensing areas. All heat treatment processes were controlled below 500degreesC in order to avoid the piezoelectric characteristics degradation of quartz crystal (Quartz will lose its piezoelectricity at -573degreesC due to the phase change from alpha to beta). The electrical and structural properties of ITO thin films were characterized with Hall analysis system, TG/DTA, XRD, XPS, SEM and etc. The gas sensor had featured with ITO thin films of -100nm as the receptor to sense the toxic gas NO and quartz crystal with frequency of 10MHz as the transducer to transfer the surface reactions ( mass loading, etc) into the frequency shift. A homemade setup had been employed to measure the sensor response under the static mode. The experimental results had indicated that the ITO-coated QCM had a good sensitivity for NO gas, -12Hz/100ppm within 5mins. These results prove that the ITO-covered quartz crystals are usable as a gas sensor and as an analytical device.
引用
收藏
页码:404 / 414
页数:11
相关论文
共 50 条
  • [21] Detection of globular and fibrillar proteins by quartz crystal microbalance sensor coated with a functionalized diamond thin film
    Prochazka, V
    Kulha, P.
    Izsak, T.
    Ukraintsev, E.
    Varga, M.
    Jirasek, V
    Kromka, A.
    APPLIED SURFACE SCIENCE, 2022, 589
  • [22] Quartz Crystal Microbalance Sensor Based onZnO-Graphene Thin Film for Gas Detection
    Boutamine, M.
    Bakha, Y.
    Saidani, H.
    Hachemi, H.
    Guerfi, A. D.
    Sebbah, C.
    Aberkane, S.
    Khales, H.
    Bellel, A.
    ACTA PHYSICA POLONICA A, 2024, 145 (05)
  • [23] Quartz crystal microbalance coated with carbon nanotube films used as humidity sensor
    Zhang, YS
    Yu, K
    Xu, RL
    Jiang, DS
    Luo, LQ
    Zhu, ZQ
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 120 (01) : 142 - 146
  • [24] Response of a Quartz Crystal Microbalance Sensor Coated with a Viscoelastic Film in Gas Phase
    Tan, Feng
    Huang, Xianhe
    SENSOR LETTERS, 2013, 11 (10) : 2000 - 2004
  • [25] Electrospun nanofibrous membranes coated quartz crystal microbalance as gas sensor for NH3 detection
    Ding, B
    Kim, JH
    Miyazaki, Y
    Shiratori, SM
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (03) : 373 - 380
  • [26] Sol-gel-derived lead titanate films
    Phillips, Nicolas J.
    Calzada, Maria L.
    Milne, Steven J.
    Journal of Non-Crystalline Solids, 1992, 147-48 : 285 - 290
  • [27] Characterisation of sol-gel-derived silica films
    McDonagh, C
    Sheridan, F
    Butler, T
    MacCraith, BD
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1996, 194 (1-2) : 72 - 77
  • [28] Wrinkling of a sol-gel-derived thin film
    Kwon, SJ
    Park, JH
    Park, JG
    PHYSICAL REVIEW E, 2005, 71 (01)
  • [29] Dewetting of a sol-gel-derived thin film
    Kwon, SJ
    Park, JG
    LANGMUIR, 2006, 22 (08) : 3895 - 3898
  • [30] Characterization of sol-gel-derived silica films
    J Non Cryst Solids, 1-2 (72):