Development of a validated ultra-high-performance liquid chromatography tandem mass spectrometry method for determination of acid diterpenes in Copaifera oleoresins

被引:37
|
作者
Mangabeira da Silva, Jonas Joaquim [1 ]
Crevelin, Eduardo Jose [2 ]
Carneiro, Luiza Junqueira [3 ]
Rogez, Herve [4 ]
Sola Veneziani, Rodrigo Cassio [3 ]
Ambrosio, Sergio Ricardo [3 ]
Beraldo Moraes, Luiz Alberto [2 ]
Bastos, Jairo Kenupp [1 ]
机构
[1] Univ Sao Paulo, Sch Pharmaceut Sci, BR-14040903 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Chem Dept, Sch Philosophy Sci & Languages, BR-14040901 Ribeirao Preto, SP, Brazil
[3] Univ Franca, Nucleus Res Sci & Technol, Av Dr Armando Salles Oliveira,201 Parque Univ, BR-14404600 Franca, SP, Brazil
[4] Fed Univ Para, Ctr Agrofood Valorizat Amazonian Bioact Cpds CVAC, BR-66075110 Belem, Para, Brazil
基金
巴西圣保罗研究基金会;
关键词
Copaifera; Oleoresin; Acid diterpenes; UPLC-MS method; Validation; RP-HPLC METHOD; COPAIBA OLEORESIN; DUCKEI DWYER; QUANTIFICATION; TERPENOIDS; SOLVENT; STATE;
D O I
10.1016/j.chroma.2017.07.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Species of Copaifera genus (Fabaceae-Caesalpinoiodidaeae) produces an important commercial oleoresin that displays many medicinal properties. Copaifera oleoresins (COR) are composed mainly of a mixture of diterpenes and sequiterpenes, and the main reported acid diterpenes for this genus are kaurenoic, copalic, hardwickiic and polyaltic acids. An ultra-performance liquid chromatography tandem mass spectrometry (UPLC MS/MS) method was developed and validated for identification and quantification of nine acid diterpenes. The developed method was applied in the analyses of 10 authentic COR samples collected in the North and Southeast of Brazil and six commercial COR samples. Samples preparation consisted of simple dilution of oleoresins in methanol followed by filtration. Validation parameters of the method for nine acid diterpenes were satisfactory: selectivity/specificity was defined by retention time and MS/MS analyses for each analyte; generally all analytical curves presented r(2) > 0.99, Lack-of-fit test not significant and RSD <20% for all concentration levels; limit of detection and limit of quantification were on the scale of nanogram per milliliter; inter- and intra-day precision and accuracy were adequate. Regarding the robustness, the method was sensible to small deliberate variations of temperature and additives to the mobile phase, such as formic acid and ammonium hydroxide. Results of 16 analyzed samples of COR showed qualitative and quantitative differences of acid diterpenes among all samples. The diterpenes ent-kaurenoic acid 1, ent-polyalthic acid 3, ent-copalic acid 5 and, ent-3-beta-acetoxy copalic acid 9 were found with more frequency in COR analyzed samples. Additionally, the content of the acid diterpenes found in 16 Copaifera oleoresin samples was analyzed by Principal Component Analysis (PCA), suggesting a botanical origin for the commercial samples. The developed UPLC method was shown to be reliable for the analysis of acid diterpenes in commercial Copaifera oleoresins. (C) 2017 Published by Elsevier B.V.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
  • [31] Multiclass method for fast determination of veterinary drug residues in baby food by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Aguilera-Luiz, M. M.
    Martinez Vidal, J. L.
    Romero-Gonzalez, R.
    Garrido Frenich, A.
    FOOD CHEMISTRY, 2012, 132 (04) : 2171 - 2180
  • [32] Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography-tandem mass spectrometry, ultra-high-performance liquid chromatography-tandem mass spectrometry and capillary liquid chromatography-mass spectrometry
    Onghena, Matthias
    Moliner-Martinez, Y.
    Pico, Yolanda
    Campins-Falco, P.
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 : 88 - 97
  • [33] Fully Validated Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Fimasartan in Human Plasma
    Hyun, Ji Yeon
    Kim, Hyun-Ju
    Gwon, Mi-Ri
    Lee, Hae Won
    Seong, Sook Jin
    Yoon, Young-Ran
    ANALYTICAL SCIENCES, 2015, 31 (12) : 1335 - 1339
  • [34] Porphyrinogen fragmentation profiles by ultra-high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry
    Benton, Christopher M.
    Lim, Chang Kee
    Moniz, Caje
    Jones, Donald J. L.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (24) : 3749 - 3757
  • [35] A validated ultra-high-performance liquid chromatography-tandem mass spectrometry method for the selective analysis of free and total folate in plasma and red blood cells
    Kiekens, Filip
    Van Daele, Jeroen
    Blancquaert, Dieter
    Van Der Straeten, Dominique
    Lambert, Willy E.
    Stove, Christophe P.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1398 : 20 - 28
  • [36] Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for determination of 10 cephalosporins and desacetylcefapirin in milk
    Hou, Xiao-Lin
    Wu, Yin-Liang
    Lv, Yan
    Xu, Xiu-Qin
    Zhao, Jian
    Yang, Ting
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 6 - 11
  • [37] Identification and quality evaluation of different processed products of Aconitum carmichaelii by ultra-high-performance liquid chromatography-quadrupole time-of-flight tandem mass spectrometry and ultra-high-performance liquid chromatography-tandem mass spectrometry
    Wei, Nina
    Song, Dandan
    Lu, Chang
    Jiang, Yong
    Liu, Qin
    Liu, Lunyuan
    Xu, Liu
    Chen, Linwei
    Chen, Zhipeng
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (17)
  • [38] Determination of Colistin B in Chicken Muscle and Egg Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Kumar, Harsh
    Kumar, Dinesh
    Nepovimova, Eugenie
    Oulkar, Dasharath
    Kumar, Anil
    Azad, Ramiz Mohammad Rafi
    Budakoti, Subodh Kumar
    Upadhyay, Navneet Kumar
    Verma, Rachna
    Kuca, Kamil
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (05) : 1 - 12
  • [39] Simultaneous determination of androgens and prostaglandins in human urine using ultra-high-performance liquid chromatography-tandem mass spectrometry
    Im, Eunju
    Lew, Bark Lynn
    Lee, Mi Yeon
    Lee, Jeongae
    Paeng, Ki Jung
    Chung, Bong Chul
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1109 : 45 - 53
  • [40] Development of a plasma pseudotargeted metabolomics method based on ultra-high-performance liquid chromatography-mass spectrometry
    Zheng, Fujian
    Zhao, Xinjie
    Zeng, Zhongda
    Wang, Lichao
    Lv, Wangjie
    Wang, Qingqing
    Xu, Guowang
    NATURE PROTOCOLS, 2020, 15 (08) : 2519 - 2537