Design and evaluation of a unipolar aerosol charger to generate highly charged micron-sized aerosol particles

被引:9
|
作者
Park, Jaehong [2 ]
Kim, Chul [2 ]
Jeong, Jimin [2 ]
Lee, Sang-Gu [1 ]
Hwang, Jungho [1 ,2 ]
机构
[1] Yonsei Univ, Dept Clean Technol Engn, Seoul 120749, South Korea
[2] Yonsei Univ, Sch Mech Engn, Seoul 120749, South Korea
关键词
Corona discharge; Unipolar charging; Aerosol particle; Micro particle;
D O I
10.1016/j.elstat.2011.02.001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, a unipolar charger for generating highly charged microparticles was designed and its performance was evaluated both theoretically and experimentally. The measured particle charge number and corona current of the charger were in good agreement with the theoretical results from FLUENT. The experimentally determined average particle charge number of 1 mu m PSL under an applied voltage of 8 kV was 128, which agreed well with the theoretically predicted and simulated values of 118 and 121, respectively. Computational calculations revealed the average charge of 10 pm particles to be 7560 at an applied voltage of 8 kV. (C) 2011 Elsevier B.V. All rights reserved.