Phase sensitive X-ray imaging: Towards medical applications

被引:0
|
作者
Kottler, Christian [1 ]
Revol, Vincent [1 ]
Maake, Caroline [2 ]
Kaufmann, Rolf [1 ]
Urban, Claus [1 ]
机构
[1] CSEM SA, Photon Div, Technopk Str 1, CH-8005 Zurich, Switzerland
[2] Univ Zurich, Inst Anat, CH-8057 Zurich, Switzerland
关键词
TOMOGRAPHY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The present work tackles the question on the evidence of X-ray phase contrast imaging with regard to a potential application in medical diagnostics. For this study the Talbot-Lau interferometer method by means of X-ray diffraction gratings was used. Specimens of human organs (e.g., adrenal gland, liver, blood vessels, etc.) were prepared and tomographic measurements were performed. The grating interferometer was developed and optimized for higher fractional Talbot orders, i.e., n = 12, in order to improve the phase sensitivity of the system. The measurements with the grating interferometer simultaneously deliver two independent projection image data sets, one reflects the X-ray attenuation coefficient, equivalent to radiography or CT, and the second one uses the refraction index, which corresponds to the phase contrast. Both data sets were reconstructed which allows for the direct comparison of the two contrast mechanisms. It was shown that the achieved phase sensitivity is sufficient to reveal anatomical details and morphology in soft tissue. Moreover, it was shown that the two contrast mechanisms can deliver complementary information. For instance, specific features, such as blood vessels, are rendered more distinct by the phase contrast images than by the attenuation images.
引用
收藏
页码:2445 / 2448
页数:4
相关论文
共 50 条
  • [31] Emerging Applications of X-Ray Imaging
    Taguchi, K.
    Li, K.
    Xing, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3635 - 3635
  • [32] X-ray imaging for security applications
    Evans, JP
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS V, 2003, 5199 : 26 - 36
  • [33] Phase Contrast X-ray Imaging Signatures for Homeland Security Applications
    Miller, Erin A.
    White, Timothy A.
    McDonald, Benjamin S.
    Seifert, Allen
    Flynn, Michael J.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 896 - 899
  • [34] Phase sensitive X-ray diffraction imaging of defects in biological macromolecular crystals
    Hu, ZW
    Lai, B
    Chu, YS
    Cai, Z
    Mancini, DC
    Thomas, BR
    Chernov, AA
    PHYSICAL REVIEW LETTERS, 2001, 87 (14) : 148101/1 - 148101/4
  • [35] Clarification of aspects in in-line phase-sensitive x-ray imaging
    Wu, Xizeng
    Liu, Hong
    MEDICAL PHYSICS, 2007, 34 (02) : 737 - 743
  • [36] X-Ray Imaging with Phase Contrast
    Bonse, Ulrich
    Beckmann, Felix
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 189 - +
  • [37] Phase contrast X-ray imaging
    Weon, Byung Mook
    Je, Jung Ho
    Hwu, Yeukuang
    Margaritondo, Giorgio
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2006, 3 (2-3) : 280 - 297
  • [38] A new phase for X-ray imaging
    Henry N. Chapman
    Nature, 2010, 467 : 409 - 410
  • [39] Phase contrast X-ray imaging
    Biomedical Imaging Center, Department of Materials Science and Engineering, Pohang University of Science and Technology, Pohang, 790-784, Korea, Republic of
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    Int. J. Nanotechnol., 2006, 2-3 (280-297):
  • [40] X-ray phase contrast imaging
    Xiong, SS
    Chen, JW
    Gao, HY
    Xie, HL
    Li, RX
    Xu, ZZ
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 3715 - 3718