Performance of a mixed binding layer for measuring anions and cations in a single assay using the diffusive gradients in thin films technique

被引:86
|
作者
Mason, S [1 ]
Hamon, R
Nolan, A
Zhang, H
Davison, W
机构
[1] Univ Adelaide, Sch Earth & Environm Sci, Adelaide, SA 5005, Australia
[2] CSIRO, Land & Water, Glen Osmond, SA 5064, Australia
[3] Natl Measurement Inst, Pymble, NSW 2073, Australia
[4] Univ Lancaster, Dept Environm Sci, IENS, Lancaster LA1 4YQ, England
关键词
D O I
10.1021/ac0507183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a mixed binding layer (MBL) for use in diffusive gradients in thin films (DGT) was investigated. The MBL consisted of ferrihydrite and Chelex-100 cation-exchange resin combined together in a binding gel in an attempt to allow measurement of anions and cations in a single assay. Results from the MBL were compared to experiments performed using individual Chelex gels and ferrihydrite gels that have been shown to work successfully for DGT methodology. To facilitate combined analysis of P and cations by ICP-MS, HCl (I. M) was used for gel elution to minimize interferences from (NOH)-N-14-O-16 or (NO)-N-15-O-16 on P-31. All elements tested (Cd, Cu, Mn, Mo, P, and Zn) were bound successfully to the MBL. An elution efficiency of 0.92 was obtained for all elements, apart from Mo (0.79). This is higher than the elution efficiencies obtained previously for pure Chelex or ferrihydrite gels using HNO3 (I M) as the eluent. Uptake of cations by DGT using the MBL was consistent across the pH range 5-9, which compares well with results using pure Chelex. Below pH 5, accumulated masses were lower for Mn, Cu, and Zn. Uptake of P and Mo was unaffected by pH in the range 3-8, and the amount absorbed compared well with results obtained previously for pure ferrihydrite gels. Performance of the MBL at different ionic strengths (0.001, 0.01 M) was comparable to performance using the pure Chelex gel. DGT measurements obtained using the MBL on agricultural soils correlated well (r(2) = 0.95) with separate measurements obtained using either pure Chelex or ferrihydrite binding layers. This suggests that the MBL could be used for simultaneous measurement of cationic and anionic element availability in soils.
引用
收藏
页码:6339 / 6346
页数:8
相关论文
共 50 条
  • [31] New diffusive gradients in a thin film technique for measuring nitrate using ion exchange resin
    Huang, Jianyin
    Bennett, William
    Teasdale, Peter
    Welsh, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [32] Effect of Biofilm on Passive Sampling of Dissolved Orthophosphate Using the Diffusive Gradients in Thin Films Technique
    Feng, Zhongmin
    Zhu, Peng
    Fan, Hongtao
    Piao, Shanshan
    Xu, Liang
    Sun, Ting
    ANALYTICAL CHEMISTRY, 2016, 88 (13) : 6836 - 6843
  • [33] Sampling of Ammonium Ion in High Salinity Waters Using Diffusive Gradients in Thin Films Technique
    Feng Zhongmin
    Yang Lan
    Sun Ting
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2021, 42 (10): : 3082 - 3090
  • [34] Sampling of Ammonium Ion in High Salinity Waters Using Diffusive Gradients in Thin Films Technique
    Feng Z.
    Yang L.
    Sun T.
    Gaodeng Xuexiao Huaxue Xuebao/Chemical Journal of Chinese Universities, 2021, 42 (10): : 3082 - 3090
  • [35] A novel method for the determination of dissolved methylmercury concentrations using diffusive gradients in thin films technique
    Gao, Yue
    De Craemer, Sam
    Baeyens, Willy
    TALANTA, 2014, 120 : 470 - 474
  • [36] Performance Characteristics of Diffusive Gradients in Thin Films Equipped with a Binding Gel Layer Containing Precipitated Ferrihydrite for Measuring Arsenic(V), Selenium(VI), Vanadium(V), and Antimony(V)
    Luo, Jun
    Zhang, Hao
    Santner, Jakob
    Davison, William
    ANALYTICAL CHEMISTRY, 2010, 82 (21) : 8903 - 8909
  • [37] Development of organic-diffusive gradients in thin films technique for measuring freely dissolved concentrations of tetracyclines using a commercial SPE packing
    Li, Xuhui
    Meng, Gengjian
    Chang, Zhuobin
    Lian, Xinxin
    Ma, Jianhua
    Guo, Ruichao
    Wang, Yulong
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2022, 234
  • [38] Performance of the diffusive gradients in thin films technique for measurement of trace metals in low ionic strength freshwaters
    Peters, AJ
    Zhang, H
    Davison, W
    ANALYTICA CHIMICA ACTA, 2003, 478 (02) : 237 - 244
  • [39] Development of diffusive gradients in thin-films with mixed binding gels for in situ monitoring of artificial sweeteners in waters
    Ijaz, Hussain
    Zi, Jin-Xin
    Liu, Si-Si
    Cai, Qi-Si
    Cheng, Sheng-Ming
    Zhao, Zong-Xi
    Ying, Guang-Guo
    Sweetman, Andy J.
    Chen, Chang-Er
    ENVIRONMENTAL SCIENCE-ADVANCES, 2023, 2 (06): : 837 - 847
  • [40] Performance characteristics of suspended particulate reagent-iminodiacetate as a binding agent for diffusive gradients in thin films
    Warnken, KW
    Zhang, H
    Davison, W
    ANALYTICA CHIMICA ACTA, 2004, 508 (01) : 41 - 51