Application of a dispersive micro-solid-phase extraction method for pre-concentration and ultra-trace determination of cadmium ions in water and biological samples

被引:40
|
作者
Behbahani, Mohammad [1 ]
Veisi, Ali [2 ]
Omidi, Fariborz [3 ]
Noghrehabadi, Aminreza [4 ]
Esrafili, Ali [5 ]
Ebrahimi, Mohammad Hossein [6 ]
机构
[1] Shohadaye Hoveizeh Univ Technol, Fac Engn, Dasht E Azadegan, Susangerd, Iran
[2] Behbahan Fac Med Sci, Behbahan, Iran
[3] Kermanshah Univ Med Sci, RCEDH, Kermanshah, Iran
[4] Shahid Chamran Univ Ahvaz, Dept Mech Engn, Ahvaz, Iran
[5] Iran Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[6] Shahroud Univ Med Sci, Occupat & Environm Hlth Res Ctr, Shahroud, Iran
关键词
Box-Behnken design; cadmium ions; modified magnetic nanoparticles; UA-D-SPE; water and biological samples; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; CLOUD POINT EXTRACTION; MAGNETIC NANOPARTICLES; ACTIVATED CARBON; BLOOD CADMIUM; SENSOR; LEAD; SYSTEM; FOOD;
D O I
10.1002/aoc.4134
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method for the trace determination of cadmium ions in water, human urine and human blood serum samples using ultrasonic-assisted dispersive micro-solid-phase extraction (UA-D-SPE) was developed. Silica-coated magnetic nanoparticles were coated with polythiophene, and the resulting sorbent was characterized using thermogravimetry, differential thermal analysis, scanning electron microscopy, Fourier transform infrared spectrometry and X-ray diffraction. Following UA-D-SPE, cadmium ions were quantified using graphite furnace atomic absorption spectrometry. A Box-Behnken design was used for optimization of important sorption and desorption parameters in UA-D-SPE: in the sorption step, pH of solution, sorption amount and sonication time for sorption; in the desorption step, concentration of eluent, volume of eluent and sonication time. The optimum conditions for the method were: pH of solution, 7.5; sonication time for sorption, 3min; sorption amount, 35mg; type and concentration of eluent, HCl and 1.1mol l(-1); volume of eluent, 360 l; sonication time for desorption, 110s. Under the optimized conditions the limit of detection and relative standard deviation for the detection of cadmium ions by UA-D-SPE were found to be 0.8ng l(-1) and <6%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Multiwalled carbon nanotubes as solid sorbent in dispersive micro solid-phase extraction for the sequential determination of cadmium and lead in water samples
    Krawczyk, Magdalena
    Jeszka-Skowron, Magdalena
    MICROCHEMICAL JOURNAL, 2016, 126 : 296 - 301
  • [32] Solidified floating organic drop microextraction for pre-concentration and trace monitoring of cadmium ions in environmental food and water samples
    Alahabadi, Ahmad
    Rastegar, Ayoob
    Esrafili, Ali
    Rezai, Zahra
    Bandegharaei, Ahmad Hosseini
    Farzadkia, Mahdi
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (08) : 1725 - 1733
  • [33] Solidified floating organic drop microextraction for pre-concentration and trace monitoring of cadmium ions in environmental food and water samples
    Ahmad Alahabadi
    Ayoob Rastegar
    Ali Esrafili
    Zahra Rezai
    Ahmad Hosseini Bandegharaei
    Mahdi Farzadkia
    Journal of the Iranian Chemical Society, 2017, 14 : 1725 - 1733
  • [34] Synthesis and comparison of four magnetic sorbents for dispersive micro-solid-phase extraction of antidiabetic drugs in urine and water samples
    Zomoorodi, Zohreh Bagheri
    Masrournia, Mahboubeh
    Abedi, Mohamad Reza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2022, 19 (08) : 3637 - 3647
  • [35] Application of Supramolecular Microextraction and Flame Atomic Absorption Spectrometry for Ultra-trace Determination of Cadmium in Food and Water Samples
    ALOthman, Z. A.
    Habila, M. A.
    Yilmaz, Erkan
    Soylak, M.
    Alwarthan, A. A.
    ATOMIC SPECTROSCOPY, 2017, 38 (03) : 51 - 56
  • [36] Synthesis and comparison of four magnetic sorbents for dispersive micro-solid-phase extraction of antidiabetic drugs in urine and water samples
    Zohreh Bagheri Zomoorodi
    Mahboubeh Masrournia
    Mohamad Reza Abedi
    Journal of the Iranian Chemical Society, 2022, 19 : 3637 - 3647
  • [37] Semiautomatic method for the ultra-trace arsenic speciation in environmental and biological samples via magnetic solid phase extraction prior to HPLC-ICP-MS determination
    Montoro-Leal, P.
    Garcia-Mesa, J. C.
    Morales-Benitez, I
    Garcia de Torres, A.
    Vereda Alonso, E.
    TALANTA, 2021, 235 (235)
  • [38] Application of syringe to syringe dispersive micro-solid phase extraction using a magnetic layered double hydroxide for the determination of cadmium(II) and lead(II) ions in food and water samples
    Arghavani-Beydokhti, Somayeh
    Rajabi, Maryam
    Asghari, Alireza
    ANALYTICAL METHODS, 2018, 10 (11) : 1305 - 1314
  • [39] Dispersive micro-solid phase extraction coupled with spectrophotometric using (MgFe CLDH)/GO magnetically separable sorbent for pre-concentration of anionic food dyes in water samples
    Mohammadi, Zarin
    Sabzehmeidani, Mohammad Mehdi
    Ghaedi, Mehrorang
    Dashtian, Kheibar
    Abbasi-Asl, Hamid
    EMERGING CONTAMINANTS, 2024, 10 (04)
  • [40] Highly selective preconcentration of ultra-trace amounts of lead ions in real water and food samples by dispersive solid phase extraction using modified magnetic graphene oxide as a novel sorbent
    Akbarzade, S.
    Chamsaz, M.
    Rounaghi, G. H.