SOLEX:: a tunable monochromatic X-ray source in the 1-20 keV energy range for metrology

被引:22
|
作者
Bonnelle, C
Jonnard, P
André, JM
Avila, A
Laporte, D
Ringuenet, H
Lépy, MC [1 ]
Plagnard, J
Ferreux, L
Protas, JC
机构
[1] Bur Natl Metrol, Lab Natl Henri Becquerel, CEA Saclay, F-91191 Gif Sur Yvette, France
[2] Univ Paris 06, Lab Chim Phys Mat & Rayonnement, CNRS, UMR 7416, F-75231 Paris 05, France
关键词
X-ray source; monochromator; calibration; curved-crystal spectrometer; X-ray detector;
D O I
10.1016/j.nima.2003.09.031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A tunable monochromatic X-ray source covering the 1-20 keV energy range is described. The initial X-ray beam is obtained. from a dedicated windowless X-ray tube. The energy selection is performed through a cylindrically bent crystal, used either in the reflection (Johann geometry) or in the transmission (Cauchois geometry) mode, by rotating the crystal holder by a 90degrees angle. Contrary to conventional geometries where the X-ray tube is fixed, here the direction of the exit beam impinging the X-ray detector is fixed. This setup is shown to be useful for various studies: high-resolution spectrometry, characterization of the response function and the efficiency of detectors and optical components, determination of transmission characteristics of different materials. Observations of the Lalpha line and Kalpha. doublet from a copper anode are presented, that demonstrate the performance of this new setup. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 50 条
  • [21] Development of a monochromatic X-ray source
    Vlieks, AE
    Caryotakis, G
    DeStefano, C
    Frederick, WJ
    Heritage, JP
    Luhmann, NC
    Martin, D
    CONFERENCE DIGEST OF THE 2004 JOINT 29TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 12TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2004, : 615 - 616
  • [22] X-ray Emission of Multiwire Z-Pinches in Energy Range Over 20 keV
    Gribov, Alexander N.
    Aleksandrov, Vladimir V.
    Grabovskiy, Evgeny V.
    Gritsuk, Arcady N.
    Medovshikov, Stanislav F.
    Mitrofanov, Konstantin N.
    Oleinik, Georgy M.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (10) : 1981 - 1986
  • [23] Optimization of a tunable quasi-monochromatic x-ray source for cell irradiations
    Neubert, W
    Enghardt, W
    Lehnert, U
    Müller, E
    Naumann, B
    Panteleeva, A
    Pawelke, J
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 123 - 128
  • [24] SOLAR X-RAY SPECTRA IN 2-20 KEV RANGE
    CHUBB, TA
    KREPLIN, RW
    FRIEDMAN, H
    ASTRONOMICAL JOURNAL, 1963, 68 (05): : 276 - &
  • [25] X-RAY FLUX FROM CENTAURUS X-2 IN ENERGY RANGE 2-20-KEV
    RAO, UR
    CHITNIS, EV
    PRAKASAR.AS
    JAYANTHI, UB
    ASTROPHYSICAL JOURNAL, 1969, 157 (2P2): : L127 - &
  • [26] A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV
    Vieira, A. A.
    Linke, A.
    Yoshimura, E. M.
    Terini, R. A.
    Herdade, S. B.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (02) : 350 - 357
  • [27] BALLOON OBSERVATION OF X-RAY SOURCES IN CYGNUS REGION IN ENERGY RANGE 20-130 KEV
    BLEEKER, JAM
    BURGER, JJ
    DEERENBE.AJ
    SCHEEPMA.A
    SWANENBU.BN
    TANAKA, Y
    ASTROPHYSICAL JOURNAL, 1967, 147 (01): : 391 - &
  • [28] X-RAY SUVEY OF NORTHERN SKY OBSERVATION OF SPECTRA IN ENERGY RANGE FROM 20 TO 100 KEV
    LEWIN, WHG
    CLARK, GW
    SMITH, WB
    ASTRONOMICAL JOURNAL, 1967, 72 (07): : 812 - &
  • [29] Fluor'X - A near monochromatic X-ray source
    Marfeld, J
    van Dorssen, GE
    Niestadt, M
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 117 - 125
  • [30] Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range
    Szabo, Csilla I.
    Feldman, Uri
    Seltzer, Stephen
    Hudson, Lawrence T.
    O'Brien, Michelle
    Park, Hye-Sook
    Seely, John F.
    OPTICS LETTERS, 2011, 36 (08) : 1335 - 1337