Development of Integrated Assessment System for Underground Power Cable Performance: A Case Study

被引:0
|
作者
Turan, Faiz Mohd [1 ]
Johan, Kartina [1 ]
Sahimi, Nur Soliha [1 ]
Nor, Nik Hisyamudin Muhd [2 ]
机构
[1] Univ Malaysia Pahang, Fac Mfg Engn, Pekan 26600, Pahang, Malaysia
[2] Univ Tun Hussein Onn Malaysia, Fac Mech & Mfg Engn, Batu Pahat 86400, Johor, Malaysia
关键词
LINES;
D O I
10.1088/1757-899X/226/1/012020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The basic operation of any electrical machines that is catered to serve needs of civilization involves electrical power which is the main source to trigger the internal mechanism in the machines then transfer the power to other form of energy such as mechanical, light, sound and etc. The supplies of electrical does not happen just by providing the source itself, it has load carrying agent which in many cases, user would refer to it as cable. Specifically, it is the power cable which its ampacity depends significantly on the operation temperature and load stress on it. Apart from having to focus on providing improvement on improving efficiency on the source itself, power cable plays and important role because without it, current ranging from low to high could not be transmitted and hence a failure of the power system generally. Studies have conducted to discuss whether which factor contributes relatively more to the causes of power cable failure or breakdown. Such factors can be narrowed down to the three major causes which are over temperature, over voltage and stress caused by over current. Over current is one of the factor which is depends on the usage of the power system itself. The higher the usage of the power system, higher the chances of over current to take place. This will then produce load stress on the cable which eventually destroy the insulator of the cable and slowly reach the core of the cable. It is believed that an assessment method should be implemented in order to predict the performance and failure rate of the power cable and use this prediction as reference rather than just letting power failure to happen anytime unpredictable which cause huge inconvenience to users and industries. Not only do a method should be implemented, it should be as easy to be used and understood by large range of users and integrated by a graphical user interface to be used. Therefore, this research will further narrow down on the approaches to do so and the location of studies involve Company M which is an agriculture industries which has higher usage on their own underground power cable. Moreover, in the past history the company experienced electrical power failure and this studies and findings will definitely come in hand to provide them necessary help and benefits.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Integrated impact assessment for sustainable development: A case study approach
    Bond, R
    Curran, J
    Kirkpatrick, C
    Lee, N
    Francis, P
    WORLD DEVELOPMENT, 2001, 29 (06) : 1011 - 1024
  • [32] Research on underground power-distribution integrated automation system
    Wang Fuzhong
    Yang Lingxiao
    Cui Lizhi
    Wang Taihua
    Yu Fashan
    Zhang Hongwei
    Progress in Mining Science and Safety Technology, Pts A and B, 2007, : 952 - 958
  • [33] Engaging citizens in the development of a health system performance assessment framework: a case study in Ireland
    Óscar Brito Fernandes
    Erica Barbazza
    Damir Ivanković
    Tessa Jansen
    Niek S. Klazinga
    Dionne S. Kringos
    Health Research Policy and Systems, 19
  • [34] Engaging citizens in the development of a health system performance assessment framework: a case study in Ireland
    Fernandes, Oscar Brito
    Barbazza, Erica
    Ivankovic, Damir
    Jansen, Tessa
    Klazinga, Niek S.
    Kringos, Dionne S.
    HEALTH RESEARCH POLICY AND SYSTEMS, 2021, 19 (01)
  • [35] Integrated Assessment of Farming System Outputs: Lithuanian Case Study
    Novikova, Anastasija
    Rocchi, Lucia
    Startiene, Grazina
    INZINERINE EKONOMIKA-ENGINEERING ECONOMICS, 2020, 31 (03): : 282 - 290
  • [36] Policy assessment in photovoltaic development using system dynamics: Case study of power generation in Iran
    Heidari, Mohammad Reza
    Heravi, Gholamreza
    SUSTAINABLE CITIES AND SOCIETY, 2023, 94
  • [37] Performance of impulse ventilation system in an underground car park fire: Case study
    Barsim, Mohsen M.
    Bassily, Magdy A.
    El-Batsh, Hesham M.
    Rihan, Yaser A.
    Sherif, Magda M.
    JOURNAL OF BUILDING ENGINEERING, 2020, 29
  • [38] DEVELOPMENT OF A SEPARABLE CONNECTOR SYSTEM FOR UNDERGROUND POWER DISTRIBUTION
    SACKS, NM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (03): : 986 - &
  • [39] Development and Assessment of Renewable Energy-Integrated Multigeneration System for Rural Communities in Nigeria: Case Study
    Bamisile, Olusola
    Huang, Qi
    Dagbasi, Mustafa
    Alowolodu, Olufunso
    Williams, Ndifreke
    JOURNAL OF ENERGY ENGINEERING, 2020, 146 (03)
  • [40] Feasibility study and performance assessment of a new tri-generation integrated system for power, cooling, and freshwater production
    Safder, Usman
    Rana, Muhammad Akmal
    Yoo, ChangKyoo
    DESALINATION AND WATER TREATMENT, 2020, 183 : 63 - 72