Effect of CT slice thickness on accuracy of implant positioning in navigated total hip arthroplasty

被引:9
|
作者
Hirasawa, N. [1 ,2 ]
Matsubara, M.
Ishii, K.
Hagio, S.
Okuda, N.
Sekiya, I. [2 ]
Muneta, T. [2 ]
机构
[1] Nissan Tamagawa Gen Hosp, Ctr Adult Hip Reconstruct, Setagaya Ku, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med, Sect Orthoped Surg, Tokyo, Japan
关键词
CT-based navigation; total hip arthroplasty; radiation exposure; REPLACEMENT;
D O I
10.3109/10929088.2010.525025
中图分类号
R61 [外科手术学];
学科分类号
摘要
CT-based navigation appears to be very accurate with regard to cup anteversion and leg length, but inaccurate with regard to stem anteversion. As for the varus/valgus angle of the stem, the navigated approach seems to be very accurate in terms of the numerical value, but this does not satisfy us: Stem anteversion is still inaccurate with this system, while cup inclination is sufficiently accurate with both navigation and manual methods. Use of 1-mm CT slices results in twice the radiation exposure associated with 3-mm CT slices, but there is little difference with respect to accuracy. It is therefore recommended to use a CT-based navigation system with 3-mm CT slices for accurate and safe total hip arthroplasty.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 50 条
  • [31] Accuracy of Implant Positioning for Minimally Invasive Total Knee Arthroplasty in Patients With Severe Varus Deformity
    Niki, Yasuo
    Matsumoto, Hideo
    Otani, Toshiro
    Enomoto, Hiroyuki
    Toyama, Yoshiaki
    Suda, Yasunori
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03): : 381 - 386
  • [32] The accuracy of positioning of a custom-made implant within a large acetabular defect at revision arthroplasty of the hip
    Baauw, M.
    van Hellemondt, G. G.
    van Hooff, M. L.
    Spruit, M.
    BONE & JOINT JOURNAL, 2015, 97B (06): : 780 - 785
  • [33] Principles and new concepts in computer-navigated total hip arthroplasty
    Renkawitz, T.
    Woerner, M.
    Sendtner, E.
    Weber, M.
    Lechler, P.
    Grifka, J.
    ORTHOPADE, 2011, 40 (12): : 1095 - +
  • [34] Accuracy of Fluoroscopic Guided Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty
    Slotkin, Eric M.
    Patel, Preetesh D.
    Suarez, Juan C.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 102 - 106
  • [35] A New Technique for Patient Registration During Navigated Total Hip Arthroplasty
    Oragui, Emeka
    Du-Moulin, Will
    Adie, Sam
    Molnar, Robert
    Harris, Laura
    TECHNIQUES IN ORTHOPAEDICS, 2021, 36 (04) : 436 - 440
  • [36] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Masahiro Fujita
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Toshihisa Maeda
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Ryosuke Kuroda
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7229 - 7235
  • [37] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Fujita, Masahiro
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Maeda, Toshihisa
    Matsushita, Takehiko
    Matsumoto, Tomoyuki
    Kuroda, Ryosuke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7229 - 7235
  • [38] HIP IMPLANT INFECTION - TREATMENT WITH RESECTION ARTHROPLASTY AND LATE TOTAL HIP-ARTHROPLASTY
    FITZGERALD, RH
    JONES, DR
    AMERICAN JOURNAL OF MEDICINE, 1985, 78 (6B): : 225 - 228
  • [39] The effect of stem length on femoral component positioning in canine total hip arthroplasty
    Dearmin, MG
    Schulz, KS
    VETERINARY SURGERY, 2004, 33 (03) : 272 - 278
  • [40] The Effect of Planning CT Slice Thickness On Evaluation of SRS Target Localization Accuracy
    Briceno, J.
    Li, H.
    Huang, Y.
    Wen, N.
    Chetty, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3270 - 3270