Determination of gadolinium(III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one

被引:106
|
作者
Zamani, Hassan Ali [1 ]
Rajabzadeh, Ghadir
Ganjali, Mohammad Reza
Norouzi, Parviz
机构
[1] Islamic Azad Univ, Quchan Branch, Dept Chem, Quchan, Iran
[2] Khorasan Sci & Technol Pk, Mashhad, Iran
[3] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[4] Univ Tehran Med Sci, Endocrine & Metabol Res Ctr, Tehran, Iran
关键词
gadolinium; 6-methyl-4-{[l-(2-thienyl)methylidenelaminol3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one; PVC membrane; potentiometry;
D O I
10.1016/j.aca.2007.07.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly selective and sensitive poly(vinyl chloride) (PVC) membrane electrodes based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one (MATDTO) as new carriers for gadolinium ion-selective electrode was reported. The membrane solutions containing PVC, o-nitrophenyl octyl ether (NPOE) as plasticizer, sodium tetraphenyl borate (NaTPB) as lipophilic ionic additive, and MATDTO, displays a calibration response for Gd3+ ions over a wide concentration range of 1.0 x 10(-6)-1.0 x 10(-1) M with Nernstian slopes of 19.8 +/- 0.2 mV per decade and a detection limit as 5.8 x 10(-7) M. The sensor has a relatively fast response time of <10s and can be used in the pH range 3.2-8.7 for at least 2 months without any significant divergence in potentials. The selectivity coefficients for mono-, di-, and trivalent cations indicate good selectivity for Gd(III) ions over a large number of interfering cations. The membrane sensor was used as an indicator electrode in the potentiometric fitration of Gd(III) ions with EDTA. The proposed electrode was also applied to the determination of concentration of Gd(III) ions in soil and sediment samples and validation with CRMs. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 33 条
  • [31] Highly selective and sensitive chromium(III) membrane sensors based on 4-amino-3-hydrazino-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore
    Zamani, Hassan Ali
    Rajabzadeh, Ghadier
    Ganjali, Mohammad Reza
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 41 - 46
  • [32] CARDIAC ELECTROPHYSIOLOGIC AND ANTIARRHYTHMIC ACTIONS OF 3,4-DIHYDRO-1'-[2-(BENZOFURAZAN-5-YL) ETHYL]-6-METHANESULFONAMIDOSPIRO[(2H)-1-BENZOPYRAN-2,4'-PIPERIDIN]-4-ONE HCL (L-691, 121), A NOVEL CLASS-III AGENT
    LYNCH, JJ
    WALLACE, AA
    VANDERGAAG, LH
    BASKIN, EP
    BEAR, CM
    GEHRET, JR
    KOTHSTEIN, T
    STUPIENSKI, RF
    APPLEBY, SD
    SANGUINETTI, MC
    JURKIEWICZ, NK
    ZINGARO, GJ
    STEIN, RB
    CLAREMON, DA
    ELLIOTT, JM
    YOUNG, MB
    BALDWIN, JJ
    JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 1993, 265 (02): : 720 - 730
  • [33] 4-OXOSPIRO[BENZOPYRAN-2,4'-PIPERIDINES] AS CLASS-III ANTIARRHYTHMIC AGENTS - PHARMACOLOGICAL STUDIES ON 3,4-DIHYDRO-1'-[2-(BENZOFURAZAN-5-YL)-ETHYL]-6-METHANESULFONAMIDOSPIRO[(2H)-1-BENZOPYRAN-2,4'-PIPERIDIN]-4-ONE (L-691,121)
    ELLIOTT, JM
    SELNICK, HG
    CLAREMON, DA
    BALDWIN, JJ
    BUHROW, SA
    BUTCHER, JW
    HABECKER, CN
    KING, SW
    LYNCH, JJ
    PHILLIPS, BT
    PONTICELLO, GS
    RADZILOWSKI, EM
    REMY, DC
    STEIN, RB
    WHITE, JI
    YOUNG, MB
    JOURNAL OF MEDICINAL CHEMISTRY, 1992, 35 (21) : 3973 - 3976