New correlations for predicting two-phase electrical submersible pump performance under downhole conditions using field data

被引:5
|
作者
Thuy Chu [1 ]
Nguyen, Tan C. [1 ]
Wang, Jihoon [2 ]
Duc Vuong [3 ]
机构
[1] New Mexico Inst Min & Technol, Socorro, NM 87801 USA
[2] Hanyang Univ, Seoul, South Korea
[3] Deepcast Co, Houston, TX USA
关键词
Electrical Submersible Pump; Pump performance; Free gas; Correlation; FLOW;
D O I
10.1007/s13202-021-01392-y
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Electrical Submersible Pump (ESP) is one of the major Artificial Lift methods that is reliable and effective for pumping high volume of fluids from wellbores. However, ESP is not recommended for applications with high gas liquid ratio. The presence of free gas inside the pump causes pump performance degradation which may lead to problems or even failure during operations. Thus, it is important to investigate effect of free gas on ESP performance under downhole conditions. At present, existing models or correlations are based on/verified with experimental data. This study is one of the first attempts to develop correlations for predicting two-phase gas-liquid pump performance under downhole conditions by using field data and laboratory data. Field data from three oil producing wells provided by Strata Production Company and Perdure Petroleum LLC. as well as experimental data obtained from experimental facility at Production and Drilling Research Project-New Mexico Tech were used in this study. Actual two-phase pump differential pressure per stage is obtained from experiments or estimated from field data and was normalized using pump performance curve. The values are compared to pump performance curve to study the relationships between pump performance and free gas percentage at pump intake. Correlations to predict ESP performance in two-phase flow under downhole and experimental conditions was derived from the results using regression technique. The correlation developed from field data presented in this study can be used to predict two-phase ESP performance under downhole conditions and under high gas fraction. The results from the experimental data confirm the reliability of the developed correlation using field data to predict two-phase ESP performance under downhole conditions. The developed correlation using the laboratory data predicts quite well the two-phase pump performance at the gas fraction of less than 15% while it is no longer reliable when free gas fraction is more than 15%. The findings from this study will help operating companies as well as ESP manufacturers to operate ESPs within the recommended range under downhole conditions. However, it is recommended to use the proposed correlation on reservoirs with conditions similar to those of the three presented wells.
引用
收藏
页码:1225 / 1235
页数:11
相关论文
共 50 条
  • [41] A new model for predicting liquid holdup in two-phase flow under high gas and liquid velocities
    Liu, Z.
    Liao, R.
    Luo, W.
    Ribeiro, J. X. F.
    SCIENTIA IRANICA, 2019, 26 (03) : 1529 - 1539
  • [42] Development of ejector performance map for predicting fixed-geometry two-phase ejector performance for wide range of operating conditions
    Haider, Muhammad
    Elbel, Stefan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 128 : 232 - 241
  • [43] Performance of drift-flux correlations for predicting void fraction of two-phase flow in tight-lattice rod bundles
    Miwa, Shuichiro
    Hibiki, Takashi
    Katono, Kenichi
    International Journal of Heat and Mass Transfer, 2022, 191
  • [44] Performance of drift-flux correlations for predicting void fraction of two-phase flow in tight-lattice rod bundles
    Miwa, Shuichiro
    Hibiki, Takashi
    Katono, Kenichi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 191
  • [45] Energy performance evaluation of two-phase injection heat pump employing low-GWP refrigerant R32 under various outdoor conditions
    Kim, Dongwoo
    Lee, DongChan
    Lee, Minwoo
    Chung, Hyun Joon
    Kim, Yongchan
    ENERGY, 2021, 214
  • [46] Analysis and separation of amyloid β-peptides using aqueous two-phase systems under stress conditions -: From aqueous two-phase system to liposome membrane system
    Kuboi, Ryoichi
    Umakoshi, Hiroshi
    SOLVENT EXTRACTION RESEARCH AND DEVELOPMENT-JAPAN, 2006, 13 : 9 - 21
  • [47] Numerical Calculation of Energy Performance and Transient Characteristics of Centrifugal Pump under Gas-Liquid Two-Phase Condition
    Zhou, Ling
    Han, Yong
    Lv, Wanning
    Yang, Yang
    Zhu, Yong
    Song, Xiangyu
    MICROMACHINES, 2020, 11 (08)
  • [48] Impact of blade twisting and tip clearance on centrifugal pump performance under air-water two-phase flow
    Mansour, Michael
    Thevenin, Dominique
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2025, 112
  • [49] Experimental investigation on the performance of a side channel pump under gas-liquid two-phase flow operating condition
    Zhang, Fan
    Boehle, Martin
    Yuan, Shouqi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2017, 231 (07) : 645 - 653
  • [50] FLOW PATTERN PREDICTION IN ELECTRICAL SUBMERSIBLE PUMP (ESP) UNDER GASSY FLOW CONDITIONS USING TRANSIENT MULTIPHASE CFD METHODS WITH VISUALIZATION EXPERIMENTAL VALIDATION
    Zhu, Jianjun
    Cuamatzi-Melendez, Ruben
    Martinez Farfan, Jose Alberto
    Zhu, Haiwen
    Zhang, Jiecheng
    Zhang, Hong-Quan
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 3, 2018,