New correlations for predicting two-phase electrical submersible pump performance under downhole conditions using field data

被引:5
|
作者
Thuy Chu [1 ]
Nguyen, Tan C. [1 ]
Wang, Jihoon [2 ]
Duc Vuong [3 ]
机构
[1] New Mexico Inst Min & Technol, Socorro, NM 87801 USA
[2] Hanyang Univ, Seoul, South Korea
[3] Deepcast Co, Houston, TX USA
关键词
Electrical Submersible Pump; Pump performance; Free gas; Correlation; FLOW;
D O I
10.1007/s13202-021-01392-y
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Electrical Submersible Pump (ESP) is one of the major Artificial Lift methods that is reliable and effective for pumping high volume of fluids from wellbores. However, ESP is not recommended for applications with high gas liquid ratio. The presence of free gas inside the pump causes pump performance degradation which may lead to problems or even failure during operations. Thus, it is important to investigate effect of free gas on ESP performance under downhole conditions. At present, existing models or correlations are based on/verified with experimental data. This study is one of the first attempts to develop correlations for predicting two-phase gas-liquid pump performance under downhole conditions by using field data and laboratory data. Field data from three oil producing wells provided by Strata Production Company and Perdure Petroleum LLC. as well as experimental data obtained from experimental facility at Production and Drilling Research Project-New Mexico Tech were used in this study. Actual two-phase pump differential pressure per stage is obtained from experiments or estimated from field data and was normalized using pump performance curve. The values are compared to pump performance curve to study the relationships between pump performance and free gas percentage at pump intake. Correlations to predict ESP performance in two-phase flow under downhole and experimental conditions was derived from the results using regression technique. The correlation developed from field data presented in this study can be used to predict two-phase ESP performance under downhole conditions and under high gas fraction. The results from the experimental data confirm the reliability of the developed correlation using field data to predict two-phase ESP performance under downhole conditions. The developed correlation using the laboratory data predicts quite well the two-phase pump performance at the gas fraction of less than 15% while it is no longer reliable when free gas fraction is more than 15%. The findings from this study will help operating companies as well as ESP manufacturers to operate ESPs within the recommended range under downhole conditions. However, it is recommended to use the proposed correlation on reservoirs with conditions similar to those of the three presented wells.
引用
收藏
页码:1225 / 1235
页数:11
相关论文
共 50 条
  • [1] New correlations for predicting two-phase electrical submersible pump performance under downhole conditions using field data
    Thuy Chu
    Tan C. Nguyen
    Jihoon Wang
    Duc Vuong
    Journal of Petroleum Exploration and Production Technology, 2022, 12 : 1225 - 1235
  • [2] Two-phase flow performance for electrical submersible pump stages
    Pessoa, R
    Prado, M
    SPE PRODUCTION & FACILITIES, 2003, 18 (01): : 13 - 27
  • [3] Modeling Oscillatory Behavior of Electrical Submersible Pump Wells Under Two-Phase Flow Conditions
    de Melo Vieira, Rinaldo Antonio
    Prado, Mauricio Gargaglione
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2014, 136 (04):
  • [4] Numerical Investigation of Turbulence Production Under Two-Phase Flow in a Simulation of Electrical Submersible Pump Performance
    Pervaiz, Salman Shahid
    Hasan, Abdulqader
    Dol, Sharul Sham
    Gadala, Mohamed S.
    ASME Open Journal of Engineering, 2022, 1 (01):
  • [5] Modeling Two-Phase Flow Inside an Electrical Submersible Pump Stage
    Barrios, Lissett
    Prado, Mauricio Gargaglione
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2011, 133 (04):
  • [6] Experimental Visualization of Two-Phase Flow Inside an Electrical Submersible Pump Stage
    Barrios, Lissett
    Prado, Mauricio Gargaglione
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2011, 133 (04):
  • [7] Numerical Study on Electrical-Submersible-Pump Two-Phase Performance and Bubble-Size Modeling
    Zhu, Jianjun
    Zhang, Hong-Quan
    SPE PRODUCTION & OPERATIONS, 2017, 32 (03): : 267 - 278
  • [8] Two-phase flow characterization in a split vane impeller Electrical Submersible Pump
    Pirouzpanah, Sahand
    Gudigopuram, Sujan R.
    Morrison, Gerald L.
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2017, 148 : 82 - 93
  • [9] CFD Modeling Inside An Electrical Submersible Pump In Two-Phase Flow Condition
    Barrios, Lissett
    Prado, Mauricio Gargaglione
    Kenyery, Frank
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 1, PTS A-C, 2009, : 457 - 469
  • [10] Experimental Study of Two-Phase Performance of an Electric-Submersible-Pump Stage
    Gamboa, Jose
    Prado, Mauricio
    SPE PRODUCTION & OPERATIONS, 2012, 27 (04): : 414 - 421