Motion estimation and correction in SPECT, PET and CT

被引:41
|
作者
Kyme, Andre Z. [1 ,4 ]
Fulton, Roger R. [2 ,3 ,4 ]
机构
[1] Univ Sydney, Sch Biomed Engn, Sydney, NSW, Australia
[2] Univ Sydney, Sydney Sch Hlth Sci, Sydney, NSW, Australia
[3] Western Sydney Local Hlth Dist, Sydney, NSW, Australia
[4] Univ Sydney, Brain & Mind Ctr, Sydney, NSW, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 18期
关键词
motion estimation; motion tracking; motion correction; motion compensation; SPECT; PET and CT; POSITRON-EMISSION-TOMOGRAPHY; CONE-BEAM CT; RESPIRATORY-GATED PET/CT; FILTERED-BACKPROJECTION ALGORITHM; VISUAL-TRACKING SYSTEM; RIGID-BODY MOTION; ANIMAL BRAIN PET; PATIENT-MOTION; HEAD MOTION; IMAGE-RECONSTRUCTION;
D O I
10.1088/1361-6560/ac093b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient motion impacts single photon emission computed tomography (SPECT), positron emission tomography (PET) and x-ray computed tomography (CT) by giving rise to projection data inconsistencies that can manifest as reconstruction artifacts, thereby degrading image quality and compromising accurate image interpretation and quantification. Methods to estimate and correct for patient motion in SPECT, PET and CT have attracted considerable research effort over several decades. The aims of this effort have been two-fold: to estimate relevant motion fields characterizing the various forms of voluntary and involuntary motion; and to apply these motion fields within a modified reconstruction framework to obtain motion-corrected images. The aims of this review are to outline the motion problem in medical imaging and to critically review published methods for estimating and correcting for the relevant motion fields in clinical and preclinical SPECT, PET and CT. Despite many similarities in how motion is handled between these modalities, utility and applications vary based on differences in temporal and spatial resolution. Technical feasibility has been demonstrated in each modality for both rigid and non-rigid motion but clinical feasibility remains an important target. There is considerable scope for further developments in motion estimation and correction, and particularly in data-driven methods that will aid clinical utility. State-of-the-art deep learning methods may have a unique role to play in this context.
引用
收藏
页数:39
相关论文
共 50 条
  • [31] An adaptive motion correction method for PET/CT Brain Imaging
    Wang, Man
    Su, Yusheng
    Lu, Jie
    Liang, Zhigang
    Yang, Defu
    Lv, Yang
    Dong, Yun
    Chen, Mu
    An, Lin
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [32] Respiratory motion artefacts in PET imaging with CT attenuation correction
    Vale, J.
    Costa, D. C.
    Fonseca, G.
    Patrina, J.
    Faria, D.
    Ponte, F.
    Teixeira, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S355 - S355
  • [33] Use of Thermal Imaging for Respiratory Motion Correction in PET/CT
    Fang, Michael
    Acuffi, Shelley
    Osborne, Dustin
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [34] Single-Phase CT Aligned to Gated PET for Respiratory Motion Correction in Cardiac PET/CT
    Wells, R. Glenn
    Ruddy, Terrence D.
    DeKemp, Rob A.
    DaSilva, Jean N.
    Beanlands, Rob S.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) : 1182 - 1190
  • [35] SinoCor: Motion Correction in SPECT
    Mitra, Debasis
    Eiland, Daniel
    Abdallah, Mahmoud
    Bouthcko, Rostyslav
    Gullberg, Grant T.
    Schechtmann, Norberto
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [36] Motion correction using anatomical information in PET/CT and PET/MR hybrid imaging
    Fayad, Hadi
    Lamare, Frederic
    Merlin, Thibaut
    Visvikis, Dimitris
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (01): : 12 - 24
  • [37] Elastic Motion Correction For Continuous Bed Motion Whole-body PET/CT
    Hong, Inki
    Jones, Judson
    Hamill, James
    Michel, Christian
    Casey, Michael
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [38] Correction of Patient Arm Motion Artifacts in PET/CT: Scatter-Limit Correction
    Bahn, Y.
    Lee, S.
    Kim, J.
    Oh, S.
    Nam-Koong, H.
    Park, H.
    Kang, C.
    Lim, H.
    Lee, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S632 - S632
  • [39] A head motion estimation algorithm for motion artifact correction in dental CT imaging
    Hernandez, Daniel
    Eldib, Mohamed Elsayed
    Hegazy, Mohamed A. A.
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [40] SPECT-CT as an alternative to PET/CT
    Schillaci, O
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S269 - S269