Motion estimation and correction in SPECT, PET and CT

被引:41
|
作者
Kyme, Andre Z. [1 ,4 ]
Fulton, Roger R. [2 ,3 ,4 ]
机构
[1] Univ Sydney, Sch Biomed Engn, Sydney, NSW, Australia
[2] Univ Sydney, Sydney Sch Hlth Sci, Sydney, NSW, Australia
[3] Western Sydney Local Hlth Dist, Sydney, NSW, Australia
[4] Univ Sydney, Brain & Mind Ctr, Sydney, NSW, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 18期
关键词
motion estimation; motion tracking; motion correction; motion compensation; SPECT; PET and CT; POSITRON-EMISSION-TOMOGRAPHY; CONE-BEAM CT; RESPIRATORY-GATED PET/CT; FILTERED-BACKPROJECTION ALGORITHM; VISUAL-TRACKING SYSTEM; RIGID-BODY MOTION; ANIMAL BRAIN PET; PATIENT-MOTION; HEAD MOTION; IMAGE-RECONSTRUCTION;
D O I
10.1088/1361-6560/ac093b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient motion impacts single photon emission computed tomography (SPECT), positron emission tomography (PET) and x-ray computed tomography (CT) by giving rise to projection data inconsistencies that can manifest as reconstruction artifacts, thereby degrading image quality and compromising accurate image interpretation and quantification. Methods to estimate and correct for patient motion in SPECT, PET and CT have attracted considerable research effort over several decades. The aims of this effort have been two-fold: to estimate relevant motion fields characterizing the various forms of voluntary and involuntary motion; and to apply these motion fields within a modified reconstruction framework to obtain motion-corrected images. The aims of this review are to outline the motion problem in medical imaging and to critically review published methods for estimating and correcting for the relevant motion fields in clinical and preclinical SPECT, PET and CT. Despite many similarities in how motion is handled between these modalities, utility and applications vary based on differences in temporal and spatial resolution. Technical feasibility has been demonstrated in each modality for both rigid and non-rigid motion but clinical feasibility remains an important target. There is considerable scope for further developments in motion estimation and correction, and particularly in data-driven methods that will aid clinical utility. State-of-the-art deep learning methods may have a unique role to play in this context.
引用
收藏
页数:39
相关论文
共 50 条
  • [1] Motion correction in PET/CT
    Schäfers, KP
    Dawood, M
    Lang, N
    Büther, F
    Schäfers, M
    Schober, O
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2005, 44 : S46 - S50
  • [2] Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: Image fusion and motion correction
    Klaus P. Schäfers
    Lars Stegger
    Basic Research in Cardiology, 2008, 103 : 191 - 199
  • [3] Combined imaging of molecular function and morphology with PET/CT and SPECT/CT:: Image fusion and motion correction
    Schaefers, Klaus P.
    Stegger, Lars
    BASIC RESEARCH IN CARDIOLOGY, 2008, 103 (02) : 191 - 199
  • [4] DETECT - Dual energy transmission estimation CT - for improved attenuation correction in SPECT and PET
    Guy, MJ
    Castellano-Smith, IA
    Flower, MA
    Flux, GD
    Ott, RJ
    Visvikis, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1261 - 1267
  • [5] DETECT - Dual Energy Transmission Estimation CT - for improved attenuation correction in SPECT and PET
    Guy, MJ
    Castellano-Smith, IA
    Flower, MA
    Flux, GD
    Ott, RJ
    Visvikis, D
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1595 - 1599
  • [6] Scatter estimation and motion correction in PET
    Thielemans, Kris
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1745 - 1747
  • [7] Rigid motion correction of PET and CT for PET/CT brain imaging
    Bickell, Matthew
    Kim, Jung-Ha
    Rezaei, Ahmadreza
    Nuyts, Johan
    Fulton, Roger
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [8] Estimation of CT Radiation Doses in SPECT/CT and PET/CT Examinations
    Sera, T.
    Porubszky, T.
    Papos, M.
    Besenyi, Z.
    Bartha, A.
    Elek, R.
    Pellet, S.
    Pavics, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S222 - S222
  • [9] Motion correction in dynamic PET/CT imaging
    Feeley, Christina
    Moore, Stephen
    Pande, Reena
    Park, Mi-Ae
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [10] Respiratory motion correction in PET with gated PET/CT data
    Iglesias, J. E.
    Kimiaei, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S315 - S315