Dose accumulation with deformable image registration method using helical tomotherapy images for prostate cancer

被引:0
|
作者
Thongsuk, Warit [1 ,2 ]
Chitapanarux, Imjai [1 ]
Wanwilairat, Somsak [1 ]
Nobnop, Wannapha [1 ]
机构
[1] Chiang Mai Univ, Fac Med, Dept Radiol, Div Radiat Oncol, 110 Intavaroros Rd, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Grad Sch, Chiang Mai, Thailand
关键词
deformable image registration; dose accumulation; helical tomotherapy; prostate cancer; RADIOTHERAPY; MOTION;
D O I
10.1017/S1460396919000256
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate changes of accumulated doses from an initial plan in each fraction by deformable image registration (DIR) with daily megavoltage computed tomography (MVCT) images from helical tomotherapy for prostate cancer patients. Materials and methods: The MVCT images of five prostate cancer patients were acquired by using a helical tomotherapy unit before the daily treatment fraction began. All images data were exported to DIR procedures by MIM software, in which the planned kilovoltage computed tomography (kVCT) images were acting as the source images with the daily MVCT acquired as the target images for registration. The automatic deformed structure was used to access the volume variation and daily dose accumulation to each structure. All dose-volume parameters were compared to the initial planned dose. Results: The actual median doses of the planning target volume (PTV) received 70 Gy and 50.4 Gy were decreased at the end of the treatment with an average 1 center dot 0 +/- 0 center dot 67% and 2 center dot 1 +/- 1 center dot 54%, respectively. As regards organs at risk (OARs), the bladder and rectum dose-volume parameters tended to increase from the initial plan. The high-dose regions of the bladder and rectum, however, were decreased from the initial plan at the end of the treatment. Conclusions: The daily actual dose differs from the initial planned dose. The accumulated dose of target tends to be lower than the initial plan, but tends to be higher than the initial plan for the OARs. Therefore, inter-fractional anatomic changes should be considered by the DIR methods, which would be useful as clinically informative and beneficial for adaptive treatment strategies.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 50 条
  • [31] Assessment of PTV Margin Reduction for Nasopharyngeal Carcinoma Using Deformable Image Registration and Dose Accumulation
    McCusker, J.
    Zhang, B.
    Wong, O.
    Lee, J.
    Bissonnette, J.
    Hope, A.
    Waldron, J.
    Bratman, S.
    Giuliani, M.
    McNiven, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 3106 - 3106
  • [32] Evaluation of dose delivery variations in Helical Tomotherapy using Helical Megavoltage CT images
    Stathakis, S.
    Mavroidis, P.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S187 - S188
  • [33] Schedule for CT image guidance in treating prostate cancer with helical tomotherapy
    Beldjoudi, G.
    Yartsev, S.
    Bauman, G.
    Battista, J.
    Van Dyk, J.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (987): : 241 - 251
  • [34] On Voxel-by-voxel Accumulated Dose for Prostate Radiation Therapy using Deformable Image Registration
    Yu, Jialu
    Hardcastle, Nicholas
    Jeong, Kyoungkeun
    Bender, Edward T.
    Ritter, Mark A.
    Tome, Wolfgang A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (01) : 37 - 47
  • [35] Prostate cancer reirradiation with Helical Tomotherapy
    Bellavita, R.
    Mariucci, C.
    Lupattelli, M.
    Matrone, F.
    Didona, A.
    Mendichi, M.
    Cecchetti, S.
    Russo, S.
    Zucchetti, C.
    Aristei, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S676 - S677
  • [36] Applying Multi-Metric Deformable Image Registration for Dose Accumulation in Combined Cervical Cancer Radiotherapy
    Fu, Qi
    Xie, Xin
    Xu, Yingjie
    Zuo, Jing
    Yang, Xi
    Xia, Wenlong
    An, Jusheng
    Huang, Manni
    Yan, Hui
    Dai, Jianrong
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [37] Evaluation of deformable image registration (DIR) methods for dose accumulation in nasopharyngeal cancer patients during radiotherapy
    Nobnop, Wannapha
    Chitapanarux, Imjai
    Neamin, Hudsaleark
    Wanwilairat, Somsak
    Lorvidhaya, Vicharn
    Sanghangthum, Taweap
    RADIOLOGY AND ONCOLOGY, 2017, 51 (04) : 438 - 446
  • [38] Deformable image registration uncertainty for inter-fractional dose accumulation of lung cancer proton therapy
    Nenoff, Lena
    Ribeiro, Cassia O.
    Matter, Michael
    Hafner, Luana
    Josipovic, Mirjana
    Langendijk, Johannes A.
    Persson, Gitte F.
    Walser, Marc
    Weber, Damien Charles
    Lomax, Antony John
    Knopf, Antje-Christin
    Albertini, Francesca
    Zhang, Ye
    RADIOTHERAPY AND ONCOLOGY, 2020, 147 : 178 - 185
  • [39] Evaluation of Dose Accumulation with Deformable Image Registration of External-Beam Radiotherapy and Brachytherapy for Cervical Cancer
    Tariq, M.
    Lavini, N.
    Souri, S.
    Gill, G.
    MEDICAL PHYSICS, 2022, 49 (06) : E200 - E201
  • [40] DEFORMABLE IMAGE REGISTRATION-BASED DOSE ACCUMULATION FOR LUNG REIRRADIATION CASES
    Di Francesco, Marco
    Popovic, Marija
    Serban, Monica
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S123 - S123