Ultra fast electron beam X-ray computed tomography for two-phase flow measurement

被引:87
|
作者
Fischer, F. [1 ]
Hampel, U. [1 ]
机构
[1] Forschungszentrum Dresden Rossendorf eV, Inst Safety Res, D-01314 Dresden, Germany
关键词
D O I
10.1016/j.nucengdes.2009.11.016
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Electron beam X-ray CT is a new technique for a fast measurement of multiphase flows with frame rates of 1000 images per second and more. It gives, in principle, quantitatively accurate images of the flow at high spatial resolution and it is non-intrusive since moderately radiation absorbing vessel walls can be penetrated by X-rays. However, on the road to a technical realisation of such a technique within a computed tomography system many problems have to be solved. As a first prototype for scientific flow measurement studies, we devised and built a fast scanned electron beam X-ray tomography scanner. The scanner consists of an electron beam unit that can be operated at up to 150 kV acceleration voltage and up to 65 mA electron beam current, with the required electron optics for beam adjustment, beam focusing and beam deflection unit and a fast circular CZT detector comprising 240 elements of 1.5 mm x 1.5 mm x 1.5 mm active pixel area. X-ray radiation is produced on a circular water cooled tungsten target. The CT system achieves up to 7000 frames per second with a spatial resolution of 1 mm. First two-phase flow experiments have been carried out on gas-water flows in bubble columns. Further, a vertical test section made of titanium alloy has been installed at the TOPFLOW facility and will be used in future to study the evolution of two-phase gas-water pipe flow at high pressures and temperatures. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2254 / 2259
页数:6
相关论文
共 50 条
  • [31] Collimated superfine x-ray beam based x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Lun, Michael
    Li, Changqing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 945 - 957
  • [32] Ultra-Sensitive X-Ray Fluorescence Computed Tomography
    Ahmad, M.
    Bazalova, M.
    Xing, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [33] MEASUREMENT OF DISTRIBUTION OF LOCAL VOID FRACTION IN 2-PHASE FLOW BY X-RAY COMPUTED-TOMOGRAPHY
    IIZUKA, M
    MOROOKA, S
    KIMURA, H
    KAGAWA, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1984, 26 (05): : 421 - 429
  • [34] Fast optimization of coded apertures in X-ray computed tomography
    Mao, Tianyi
    Cuadros, Angela P.
    Ma, Xu
    He, Weiji
    Chen, Qian
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2018, 26 (19): : 24461 - 24478
  • [35] A hybrid approach for fast simulation of x-ray computed tomography
    Ay, M. R.
    Gafarian, P.
    Zaidi, H.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3155 - +
  • [36] Investigation on applicability of time-averaged X-ray CT images in two-phase flow measurement
    Nukaga, Jun
    Katono, Kenichi
    Sadaoka, Noriyuki
    Yasuda, Kenichi
    Aoki, Toru
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2019, 56 (12) : 1130 - 1140
  • [37] COMPUTED TOMOGRAPHY WITH AN X-RAY TRANSMISSION PENCIL BEAM SCANNER
    KAMBIC, GX
    WAKE, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (02) : 874 - 880
  • [38] Evaluation of Computed Tomography X-Ray Beam Dose Profiles
    Civa, Lejla M.
    Beganovic, Adnan
    Redzic, Mahira
    Lasic, Ivan
    Gazdic-Santic, Maja
    Skopljak-Beganovic, Amra
    Jasic, Rahima
    Vegar-Zubovic, Sandra
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, CMBEBIH 2019, 2020, 73 : 137 - 141
  • [39] Application of x-ray image magnifier and demagnifier to parallel beam x-ray computed tomography
    Hirano, K.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (05)
  • [40] Simulating Two-Phase Seepage in Undisturbed Soil Based on Lattice Boltzmann Method and X-ray Computed Tomography Images
    Jiang, Zhenliang
    Lin, Yiqian
    Chen, Xian
    Li, Shanghui
    Cai, Peichen
    Que, Yun
    SENSORS, 2024, 24 (13)