Chronic intracranial artery stenosis: Comparison of whole-brain arterial spin labeling with CT perfusion

被引:9
|
作者
Tian, Bing [1 ]
Liu, Qi [1 ]
Wang, Xinrui [1 ]
Chen, Shiyue [1 ]
Xu, Bing [1 ]
Zhu, Chengcheng [2 ]
Lu, Jianping [1 ]
机构
[1] Second Mil Med Univ, Dept Radiol, Changhai Hosp Shanghai, Shanghai 200433, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94121 USA
关键词
Arterial spin labeling; CT perfusion; MCA stenosis; Chronic ischemic stroke; ACUTE ISCHEMIC-STROKE; ASSESSING AGREEMENT; MRI;
D O I
10.1016/j.clinimag.2018.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential clinical value of Arterial spin-labeled (ASL) through comparison with computed tomography perfusion (CTP) in patients with chronic intracranial artery (middle cerebral artery, MCA) stenosis. Methods: Twenty-nine patients (14 female, average ages 62) were included in our study from October 2013 to August 2016. Relative cerebral blood flow (rCBF) in the MCA territory was calculated on both ASL and CTP. Patients were divided into three groups (mild, moderate and severe) based on their degree of MCA stenosis on DSA. The paired t-tests and Bland-Altman plots were used to evaluate the differences of rCBF between ASL and CTP. Results: There was a significant difference in rCBF between ASL and CTP for all patients (P < 0.001) and for those with severe MCA stenosis (P < 0.001). For patients with mild or moderate stenosis, there were no significant differences (P = 0.496 and 0.645, respectively). The 95% limits of agreement for all patients and those with severe stenosis were (-0.25, 0.41) and ( - 0.13, 0.56), respectively. For patients with mild or moderate stenosis, the values were ( - 0.21, 0.22) and ( -0.20, 0.19). Conclusion: Compared with CTP, ASL tended to overestimate the perfusion deficit in patients with severe chronic MCA stenosis. However, ASL is noninvasive, repeatable method and can be a promising clinical diagnostic tool to evaluate patients with intracranial stenosis.
引用
收藏
页码:252 / 259
页数:8
相关论文
共 50 条
  • [41] Measurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)
    Boudes, Elodie
    Gilbert, Guillaume
    Leppert, Ilana Ruth
    Tan, Xianming
    Pike, G. Bruce
    Saint-Martin, Christine
    Wintermark, Pia
    NEUROIMAGE-CLINICAL, 2014, 6 : 126 - 133
  • [42] Intra- and Interscanner Reliability and Reproducibility of 3D Whole-Brain Pseudo-Continuous Arterial Spin-Labeling MR Perfusion at 3T
    Wu, Bing
    Lou, Xin
    Wu, Xinhuai
    Ma, Lin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 402 - 409
  • [43] Noncontrast Pediatric Brain Perfusion Arterial Spin Labeling and Intravoxel Incoherent Motion
    Wang, Danny J. J.
    Le Bihan, Denis
    Krishnamurthy, Ram
    Smith, Mark
    Ho, Mai-Lan
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 493 - 513
  • [44] Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI
    Qu, Yaoming
    Kong, Dexia
    Wen, Haitao
    Ou, Xiaochan
    Rui, Qihong
    Wang, Xianlong
    Lin, Doris D.
    Qin, Qin
    Wen, Zhibo
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 2976 - 2987
  • [45] Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI
    Yaoming Qu
    Dexia Kong
    Haitao Wen
    Xiaochan Ou
    Qihong Rui
    Xianlong Wang
    Doris D. Lin
    Qin Qin
    Zhibo Wen
    European Radiology, 2022, 32 : 2976 - 2987
  • [46] LONGITUDINAL ANALYSIS OF ARTERIAL SPIN LABELING PERFUSION IN MILD TRAUMATIC BRAIN INJURY
    Zhang, Tianhao
    Masdeu, Joseph
    Lebel, Robert
    Sui, Yunxia
    Mukherjee, Pratik
    Shetty, Teena
    Marinelli, Luca
    JOURNAL OF NEUROTRAUMA, 2016, 33 (13) : A31 - A32
  • [47] Improved Pseudo-Continuous Arterial Spin Labeling for Mapping Brain Perfusion
    Nezamzadeh, Marzieh
    Matson, Gerald B.
    Young, Karl
    Weiner, Michael W.
    Schuff, Norbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (06) : 1419 - 1427
  • [48] Stability of MR brain-perfusion measurement using arterial spin labeling
    Jan Petr
    Frank Hofheinz
    Ivan Platzek
    Georg Schramm
    Jorg Van Den Hoff
    EJNMMI Physics, 2 (Suppl 1)
  • [49] Whole-Brain Perfusion via Right Common Carotid Artery With Type 2 Proatlantal Intersegmental Artery
    Zuflacht, Jonah P.
    Liang, Chuan
    Burkhardt, Jan-Karl
    Favilla, Christopher G.
    STROKE, 2022, 53 (11) : E481 - E482
  • [50] Whole-brain CT perfusion imaging using increased sampling intervals: A pilot study
    Cao, Guoquan
    Chen, Weijian
    Sun, Houzhang
    Guo, Xianzhong
    Yang, Yunjun
    Tang, Kun
    Liu, Jinjin
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (03) : 2643 - 2649