An improved single phase transformerless inverter topology for grid connected PV system with reduce leakage current and reactive power capability

被引:21
|
作者
Ahmad, Zameer [1 ]
Singh, S. N. [1 ]
机构
[1] Indian Inst Technol Roorkee, Alternate Hydro Energy Ctr, Roorkee, Uttar Pradesh, India
关键词
Transformerless; Leakage current; Photovoltaic; Common mode voltage; Reactive power; PHOTOVOLTAIC SYSTEMS; SYNCHRONIZATION;
D O I
10.1016/j.solener.2017.08.007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Single phase transformerless inverters are widely being adopted for small scale grid connected PV systems due to their high efficiency, lower cost and high power density. However, leakage current is the main concern in these inverters which needs to be addressed carefully. Moreover, PV inverters should also be capable of injecting a definite amount of reactive power into the grid as prescribed by the international regulations. In this paper, an improved H6 common mode voltage (CMV) clamped topology with modified modulation strategy is proposed. The proposed topology offers low loss ac side decoupling, complete elimination of leakage current via CMV clamping and reactive power generation capability. The proposed modulation technique facilitates the flow of current in order to generate zero voltage state during negative power flow. Total harmonic distortion (THD) of injected grid current at various solar irradiance levels is also analyzed. Moreover, implementation of inverter control algorithm in real time digital simulator (OP-5600) has been discussed in detail. In order to justify the suitability of the proposed topology for grid-tied PV system, simulations have been carried out in Matlab/Simulink environment and validated through an experimental setup. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:133 / 146
页数:14
相关论文
共 50 条
  • [21] Improved Transformerless Inverter With Common-Mode Leakage Current Elimination for a Photovoltaic Grid-Connected Power System
    Yang, Bo
    Li, Wuhua
    Gu, Yunjie
    Cui, Wenfeng
    He, Xiangning
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) : 752 - 762
  • [22] Leakage Current Attenuation of a Three-Phase Cascaded Inverter for Transformerless Grid-Connected PV Systems
    Guo, Xiaoqiang
    Zhou, Jiale
    He, Ran
    Jia, Xiaoyu
    Rojas, Christian A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) : 676 - 686
  • [23] A Single-Phase Grid-Connected PV Inverter with Improved Grid-connected Current
    Xiao, Furong
    Dong, Lei
    Liao, Xiaozhong
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4083 - 4088
  • [24] A Novel Single-Phase Transformerless Grid-Connected PV Inverter
    Cunha, Arnaldo O., Jr.
    Bahia, Filipe A. C.
    Mello, Joao P. R. A.
    Tahim, Andre P. N.
    Costa, Fabiano F.
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [25] Improved Single-phase Transformerless Y-source PV Grid-connected Inverter
    Ran Y.
    Wang W.
    Wang Y.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (03): : 1086 - 1095
  • [26] A Novel Inverter Topology for Single-Phase Transformerless PV System
    Cao, Haiyan
    ACTIVE AND PASSIVE ELECTRONIC COMPONENTS, 2016, 2016
  • [27] Single-Phase Transformerless PV Inverter with Reactive Power Compensation
    Prakash, Jishnu K.
    Hemarani, P.
    2022 IEEE INTERNATIONAL POWER AND RENEWABLE ENERGY CONFERENCE, IPRECON, 2022,
  • [28] New Topology to Reduce Leakage Current in Three-Phase Transformerless Grid-Connected Photovoltaic Inverters
    Rahimi, Ramin
    Farhangi, Babak
    Farhangi, Shahrokh
    2016 7TH POWER ELECTRONICS AND DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC), 2016, : 421 - 426
  • [29] A Single Stage Doubly Grounded Transformerless Inverter Topology With Buck-Boost Voltage Capability for Grid Connected PV Systems
    Chamarthi, Phani Kumar
    El Moursi, Mohamed Shawky
    Khadkikar, Vinod
    Al Hosani, Khalifa Hassan
    Al-Durra, Ahmed
    EL-Fouly, Tarek H. M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (06) : 5044 - 5058
  • [30] Three-Phase Transformerless Grid-Connected Photovoltaic Inverter to Reduce Leakage Currents
    Freddy, Tan Kheng Suan
    Abd Rahim, Nasrudin
    Ping, Hew Wooi
    2013 IEEE CONFERENCE ON CLEAN ENERGY AND TECHNOLOGY (CEAT), 2013, : 277 - 280