Scapular muscle tests in subjects with shoulder pain and functional loss: Reliability and construct validity

被引:0
|
作者
Michener, LA
Boardman, ND
Pidcoe, PE
Frith, AM
机构
[1] Virginia Commonwealth Univ, Dept Phys Therapy, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Dept Orthopaed Surg, Richmond, VA 23298 USA
[3] Southside Rehabil Serv, Colonial Hts, VA USA
来源
PHYSICAL THERAPY | 2005年 / 85卷 / 11期
关键词
measurement; muscles; reproducibility of results; scapula; shoulder;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. Scapular muscle performance evaluated with a handheld dynamometer (HHD) has been. investigated only in people without shoulder dysfunction for test-retest reliability of data obtained with a single scapular muscle test. The purpose of this study was to assess the reliability, error, and validity of data obtained with an HHD for 4 scapular muscle tests in subjects with shoulder pain and functional loss. Subjects and Methods. Subjects (N=40) with shoulder pain band functional loss were tested by measuring the kilograms applied with an HHD during 3 trials for muscle tests for the lower trapezius, upper trapezius, middle trapezius, and serratus anterior muscles. Concurrently, surface electromyography (sEMG) data were collected for the 4 muscles. The same procedures were performed 24 to 72 hours after the initial testing by the same tester. Muscle tests were per-formed 3 times, and the results were averaged for data analysis. Results. Intraclass correlation coefficients for intratester reliability of measurements of isometric force obtained using an HHD ranged from.89 to .96. The standard error of the measure (90% confidence interval [CI]) ranged from 1.3 to 2.7 kg; the minimal detectable change (90% CI) ranged from 1.8 to 3.6 kg. Construct validity assessment, done by comparing the amounts of isometric muscle activity (sEMG) for each muscle across the 4 muscle tests, revealed that the muscle activity of the upper trapezius and lower trapezius muscles was highest during their respective tests. Conversely, the isometric muscle activity of the middle trapezius and serratus anterior muscles was not highest during their respective tests. Discussion and Conclusion. In people with shoulder pain and functional loss, the intrarater reliability and error over 1 to 3 days were established using an HHD for measurement of isometric force for the assessment of scapular muscle performance. Error values can be used to make decisions regarding individual patients. Construct validity was established for the lower and upper trapezius muscle tests; therefore, these tests are advocated for use. However, construct validity was not demonstrated for the serratus anterior and middle trapezius muscle tests as performed in this study. Further investigation of these muscle tests is warranted. [Michener LA, Boardman ND, Pidcoe PE, Frith AM. Scapular muscle tests in subjects with shoulder pain and functional loss: reliability and construct validity.
引用
收藏
页码:1128 / 1138
页数:11
相关论文
共 50 条
  • [41] The structure, reliability and validity of pain expression: Evidence from patients with shoulder pain
    Prkachin, Kenneth M.
    Solomon, Patricia E.
    PAIN, 2008, 139 (02) : 267 - 274
  • [42] The patient enablement instrument for back pain: reliability, content validity, construct validity and responsiveness
    Nielsen, A. Molgaard
    Hartvigsen, J.
    Kongsted, A.
    Oberg, B.
    Enthoven, P.
    Abbott, A.
    Lauridsen, H. H.
    HEALTH AND QUALITY OF LIFE OUTCOMES, 2021, 19 (01)
  • [43] The patient enablement instrument for back pain: reliability, content validity, construct validity and responsiveness
    A. Molgaard Nielsen
    J. Hartvigsen
    A. Kongsted
    B. Öberg
    P. Enthoven
    A. Abbott
    H. H. Lauridsen
    Health and Quality of Life Outcomes, 19
  • [44] Shoulder Performance Activity Test (SPAT) for People With Shoulder Pain: Feasibility, Reliability and Validity
    Sousa, Catarina O.
    Nascimento, Jose Diego S.
    Pozzi, Federico
    Kardouni, Joseph R.
    Michener, Lori A.
    PHYSICAL THERAPY, 2023, 103 (03):
  • [45] Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests
    Rijken, Noortje H.
    van Engelen, Baziel G.
    Weerdesteyn, Vivian
    Geurts, Alexander C.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (12): : 2201 - 2206
  • [46] KINESIO-PERCEPTUAL TESTS RELIABILITY AND VALIDITY WITH RETARDED SUBJECTS
    GROSS, JC
    JOINER, LM
    HOLT, LE
    SOMMERS, P
    JOURNAL OF SPECIAL EDUCATION, 1970, 4 (02): : 223 - 231
  • [47] The prevalence of scapular dyskinesia in patients with back, neck, and shoulder pain and the effect of this combination on pain and muscle shortness
    Saglam, Gonca
    Telli, Hilal
    AGRI-THE JOURNAL OF THE TURKISH SOCIETY OF ALGOLOGY, 2022, 34 (02): : 100 - 108
  • [48] Reliability and validity of functional balance tests post stroke
    Tyson, SF
    DeSouza, LH
    CLINICAL REHABILITATION, 2004, 18 (08) : 916 - 923
  • [49] Validity, Reliability and Responsiveness of the Malay Shoulder Pain and Disability Index (M-SPADI) for Patients with Shoulder Pain
    Abdul-Karim, S.
    Abdul-Hamid, M. S.
    Ho, C. A.
    Ling, J. C. Y.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2023, 17 (01) : 160 - 171
  • [50] Reliability and Construct Validity of the Psoriasis Symptom Inventory in Subjects with Psoriatic Arthritis.
    Mease, Philip
    Genovese, Mark C.
    Mutebi, Alex
    Wilson, Hilary
    Revicki, Dennis
    Erondu, Ngozi
    Nirula, Ajay
    Feng, JingYuan
    Viswanathan, Hema
    ARTHRITIS & RHEUMATOLOGY, 2014, 66 : S240 - S240