A pneumatic phantom for mimicking respiration-induced artifacts in spinal MRI

被引:10
|
作者
De Tillieux, Philippe [1 ]
Topfer, Ryan [1 ]
Foias, Alexandru [1 ]
Leroux, Iris [1 ]
El Maachi, Imanne [1 ]
Leblond, Hugues [2 ]
Stikov, Nikola [1 ,3 ]
Cohen-Adad, Julien [1 ,4 ]
机构
[1] Polytech Montreal, Inst Biomed Engn, NeuroPoly Lab, Montreal, PQ, Canada
[2] Univ Quebec Trois Rivieres, Dept Anat, Trois Rivieres, PQ, Canada
[3] Univ Montreal, Montreal Heart Inst, Montreal, PQ, Canada
[4] Univ Montreal, Funct Neuroimaging Unit, CRIUGM, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
spectroscopic localization; dynamic31P MRS; exercising muscle; multivoxel; MOTION; BREAST; HEART; FIELD; SHIM; CORD; B-0;
D O I
10.1002/mrm.26679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo design a phantom capable of mimicking human respiration to serve as a testing platform for correction of the static and time-evolving magnetic field distortions typically encountered in MRI of the spinal cord. MethodsAn inflation system to mimic the air variation of the human lungs was constructed. The inflation system was linked to a phantom containing synthetic lungs and an ex vivo human spine. The relationship between air pressure and phantom lung volume was evaluated via imaging experiment. The geometric distortion (pseudo-displacement) caused by the B0 inhomogeneities was measured on echo planar imaging slices for different air volumes. ResultsLinear and quadratic relations linking air pressure to phantom lung volume were observed with a Pearson correlation coefficient of 0.99. Air distribution was uneven across the synthetic lungs, exhibiting a left-to-right lung volume ratio of up to 5/4. The pseudo-displacement artifact of the spine caused by the air-filled lungs was observed. ConclusionThe proposed phantom can reproduce the lung volume variation of human respiration and thus can serve as a reliable testing platform for the correction of the associated time-varying B-0 field distortions. Details of the construction and code for the inflation system microcontroller are available for download as open source. Magn Reson Med 79:600-605, 2017. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:600 / 605
页数:6
相关论文
共 50 条
  • [31] Correction of Respiration-Induced Cardiac Motion in SPECT Myocardial Perfusion Imaging
    Parker, J.
    Mair, B.
    Gilland, D.
    MEDICAL PHYSICS, 2008, 35 (06) : 2674 - +
  • [32] Correlation between respiration-induced thoracic expansion and a shift of central structures
    M. Weckesser
    L. Stegger
    K. U. Juergens
    D. Wormanns
    W. Heindel
    O. Schober
    European Radiology, 2006, 16 : 1614 - 1620
  • [33] Correlation of Respiration-Induced Motion of an External Surrogate and Implanted Internal Markers
    Lu, J.
    Brackbill, E.
    Zheng, D.
    Weiss, E.
    Hugo, G.
    Keall, P.
    Poulsen, P.
    Fledelius, W.
    Williamson, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [34] Modulation of respiration-induced heart rate fluctuation by mastication and swallowing.
    Nitta, E
    Shiba, Y
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1342 - 1342
  • [35] Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy
    Arai, Tatsuya J.
    Nofiele, Joris
    Madhuranthakam, Ananth J.
    Yuan, Qing
    Pedrosa, Ivan
    Chopra, Rajiv
    Sawant, Amit
    MEDICAL PHYSICS, 2016, 43 (06) : 2807 - 2820
  • [36] Real-time correction of respiration-induced distortions in the human spinal cord using a 24-channel shim array
    Topfer, Ryan
    Foias, Alexandru
    Stikov, Nikola
    Cohen-Adad, Julien
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) : 935 - 946
  • [37] An analysis of the treatment couch and control system dynamics for respiration-induced motion compensation
    D'Souza, Warren D.
    McAvoy, Thomas J.
    MEDICAL PHYSICS, 2006, 33 (12) : 4701 - 4709
  • [38] Respiration-Induced Kidney Motion on Cobalt-Chromium Stent Fatigue Resistance
    Hsiao, Hao-Ming
    Nikanorov, Alexander
    Prabhu, Santosh
    Razavi, Mahmood K.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (02) : 508 - 516
  • [39] Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data
    Frank, LR
    Buxton, RB
    Wong, EC
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 635 - 644
  • [40] Assessment of Respiration-Induced Motion and Its Impact on Treatment Outcome for Lung Cancer
    Wang, Yan
    Bao, Yong
    Zhang, Li
    Fan, Wei
    He, Han
    Sun, Zong-Wen
    Hu, Xiao
    Huang, Shao-Min
    Chen, Ming
    Deng, Xiao-Wu
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013