Analysis of H- Extraction in the Linac4 Negative Ion Source by 2.5D Particle Simulation

被引:1
|
作者
Abe, S. [1 ]
Nishioka, S. [1 ]
Maffei, S. [2 ]
Miyamoto, K. [3 ]
Hatayama, A. [1 ]
Lettry, J. [2 ]
机构
[1] Kew Univ, Fac Sci & Technol, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] CERN, CH-1211 Geneva 23, Switzerland
[3] Naruto Univ Educ, 748 Nakajima,Naruto Cho, Naruto, Tokushima 7728502, Japan
关键词
D O I
10.1063/1.5053375
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this study is to investigate the extraction mechanisms of the H- ions in the Linac4 negative ion source by using an improved two-dimensional in real space and three-dimensional in velocity space Particle in Cell (2D3VPIC) model. In this model, the following collision processes of the surface produced H- (H-sp(-)) ions have been introduced and the effects of the collisions on H- extraction have been analyzed: elastic (H-sp(-)-H-2) and charge exchange (1-1;- H). It is shown that the extracted H-sp(-) current increases due to the tlow reversal of the H-sp(-) ions caused by these collisions.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator
    Kalvas, T.
    Welton, R. F.
    Tarvainen, O.
    Han, B. X.
    Stockli, M. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [42] Optimization and numerical simulation for the extraction system of the H- multicusp ion source
    Hosseinzadeh, M.
    Afarideh, H.
    CHINESE PHYSICS C, 2014, 38 (05)
  • [43] Analysis of the H- ion emissive surface in the extraction region of negative ion sources
    Kameyama, N.
    Fukuyama, T.
    Wada, S.
    Kuppel, S.
    Tsumori, K.
    Nakano, H.
    Hatayama, A.
    Miyamoto, K.
    Fukano, A.
    Bacal, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [44] 2D simulation and optimization of the volume H- ion source extraction system for the spallation neutron source accelerator
    Leitner, MA
    Wutte, DC
    Leung, KN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 427 (1-2): : 242 - 249
  • [45] D-/H- negative ion production versus plasma parameters in a volume negative ion source
    Mori, Shigefumi
    Fukumasa, Osamu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [46] The extraction of both positive and negative ions from a volume cusp H- ion source
    Melanson, Stephane
    George, Anand
    Dehnel, Morgan
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [47] Characterization of cesium and H-/D- density in the negative ion source SPIDER
    Barbisan, Marco
    Agnello, R.
    Baldini, L.
    Casati, G.
    Fadone, M.
    Pasqualotto, R.
    Rizzolo, A.
    Sartori, E.
    Serianni, G.
    FUSION ENGINEERING AND DESIGN, 2023, 194
  • [48] Importance of electric field for H- extraction in a volume-type hydrogen negative ion source
    Matsumoto, Y.
    Nishiura, M.
    Sasao, M.
    Yamaoka, H.
    Shinto, K.
    Wada, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [49] Uniform H- ion beam extraction in a large negative ion source with a tent-shaped magnetic filter
    Tobari, H.
    Hanada, M.
    Kashiwagi, M.
    Taniguchi, M.
    Umeda, N.
    Watanabe, K.
    Inoue, I.
    Sakamoto, K.
    Takado, N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [50] Enhancement of H-/D- volume production in a double plasma type negative ion source
    Fukumasa, O
    Nishimura, H
    Sakiyama, S
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1996, (380): : 288 - 299