Methods of Lightning Protection for the PV Power Plant

被引:0
|
作者
Tan, Pi Hua [1 ]
Gan, Chin Kim [2 ]
机构
[1] Sharp Roxy Sales & Serv Co M Sdn Bhd, Solar Dept, Shah Alam, Malaysia
[2] Univ Tekn Malaysia Melaka, Fac Elect Engn, Durian Tunggal, Malaysia
关键词
Lightning; PV cable; mounting structure; Crystalline; Thin Film; energy comparison; protection;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the comparison between air terminal lightning Pole and Early Streamer Emitter lightning Pole in a Photovoltaic (PV) Power Plants. The installation of an external lightning protection system is crucial for power plants to minimize PV system damages. Two different lightning systems were installed to two different PV technology Power Plant systems. The respective system performances were compared in terms of total energy generated and energy yield. The key findings suggest that the air termination lightning pole is suitable for a solar power plant particularly a Thin Film or Crystalline PV power plant system that will result in lower losses compared to the Early Streamer Emitter lightning pole for the PV Power Plant system. This is caused by the shadow of lightning poles that drops on the PV modules to increase solar cell temperature and reduce power generation. Malaysia has one of highest occurrences of lightning activities in the world. Thus, it is essential for PV power plants to have adequate protection from damage and power generation losses.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 50 条
  • [41] Environmental Friendly PV Power Plant
    Chen, Nuofu
    Zhang, Xiulan
    Bai, Yiming
    Zhang, Han
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT A, 2012, 16 : 32 - 37
  • [42] LIGHTNING PROTECTION OF OVERHEAD POWER LINES BY MEANS OF LIGHTNING LEADERS MOVERMENT SIMULATION
    Tavakoli, M. R. Bank
    Vahidi, B.
    Mirtadjaddini, S. N.
    Nasrollahi, A.
    Azinfar, F.
    Hajesmaeeli, I.
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [43] Investigation of lightning surge effects on a grid-connected PV plant
    Bokoro, P.
    Doorsamy, W.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [44] Lightning protection methods: An update and a discredited system vindicated
    Zipse, DW
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (02) : 407 - 414
  • [45] ANALYSIS OF LIGHTNING EFFECTS ON POWER PLANT CONNECTION
    Mestriner, Daniele
    Invernizzi, Marco
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2018, 38 (02): : 40 - 49
  • [46] Lightning protection methods: An update and a discredited system vindicated
    Zipse, DW
    2000 IEEE INDUSTRIAL & COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2000, : 155 - 170
  • [47] The development of methods of analyzing the effectiveness of substation lightning protection
    Vlasko D.I.
    Domonov A.P.
    Efimov B.V.
    Nevretdinov Yu.M.
    Power Technology and Engineering, 1600, Springer Science and Business Media, LLC (47): : 226 - 232
  • [48] Lightning protection of high-performance photovoltaic power plants: Issues of parts to be covered by the lightning protection system
    Tóth Z.
    Kiss I.
    Németh B.
    Berta I.
    Periodica polytechnica Electrical engineering and computer science, 2021, 65 (01): : 20 - 28
  • [49] Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
    Khurshid, Z. M.
    Gomes, C.
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [50] Research on lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    Sato, Tomoyuki
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (10): : 2317 - 2328