Diffusion-weighted magnetic resonance imaging in rat kidney using two-dimensional navigated, interleaved echo-planar imaging at 7.0 T

被引:1
|
作者
Liu, Qiang [1 ,2 ,3 ,4 ,5 ]
Xu, Zhongbiao [6 ]
Zhao, Kaixuan [1 ,2 ,3 ,4 ,5 ]
Hoge, W. Scott [7 ,8 ]
Zhang, Xinyuan [1 ,2 ,3 ,4 ,5 ]
Mei, Yingjie [1 ,2 ,3 ,4 ,5 ]
Lu, Qiqi [1 ,2 ,3 ,4 ,5 ]
Niendorf, Thoralf [9 ]
Feng, Yanqiu [1 ,2 ,3 ,4 ,5 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, 1838 Guangzhou Ave N, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Guangdong Prov Engn Lab Med Imaging & Diagnost Te, Guangzhou, Peoples R China
[4] Southern Med Univ, Minist Educ, Guangdong Hong Kong Macao Greater Bay Area Ctr Br, Guangzhou, Peoples R China
[5] Southern Med Univ, Minist Educ, Key Lab Mental Hlth, Guangzhou, Peoples R China
[6] Guangdong Prov Peoples Hosp, Guangdong Acad Med Sci, Dept Radiat Oncol, Guangzhou, Peoples R China
[7] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[8] Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
[9] Max Delbrueck Ctr Mol Med Helmholtz Assoc, Berlin Ultrahigh Field Facil BUFF, Berlin, Germany
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
DWI; EPI; kidney; MRI; multishot; navigator; READOUT-SEGMENTED EPI; MR-CAT-SCAN; RENAL FIBROSIS; MURINE MODEL; RESOLUTION; MATHEMATICS; ACQUISITION; ANISOTROPY; SENSE; SPIN;
D O I
10.1002/nbm.4652
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to investigate the feasibility of two-dimensional (2D) navigated, interleaved multishot echo-planar imaging (EPI) to enhance kidney diffusion-weighted imaging (DWI) in rats at 7.0 T. Fully sampled interleaved four-shot EPI with 2D navigators was tailored for kidney DWI (Sprague-Dawley rats, n = 7) on a 7.0-T small bore preclinical scanner. The image quality of four-shot EPI was compared with T-2-weighted rapid acquisition with relaxation enhancement (RARE) (reference) and single-shot EPI (ss-EPI) without and with parallel imaging (PI). The contrast-to-noise ratio (CNR) was examined to assess the image quality for the EPI approaches. The Dice similarity coefficient and the Hausdorff distance were used for evaluation of image distortion. Mean diffusivity (MD) and fractional anisotropy (FA) were calculated for renal cortex and medulla for all DWI approaches. The corticomedullary difference of MD and FA were assessed by Wilcoxon signed-rank test. Four-shot EPI showed the highest CNR among the three EPI variants and lowest geometric distortion versus T-2-weighted RARE (mean Dice: 0.77 for ss-EPI without PI, 0.88 for ss-EPI with twofold undersampling, and 0.92 for four-shot EPI). The FA map derived from four-shot EPI clearly identified a highly anisotropic region corresponding to the inner stripe of the outer medulla. Four-shot EPI successfully discerned differences in both MD and FA between renal cortex and medulla. In conclusion, 2D navigated, interleaved multishot EPI facilitates high-quality rat kidney DWI with clearly depicted intralayer and interlayer structure and substantially reduced image distortion. This approach enables the anatomic integrity of DWI-MRI in small rodents and has the potential to benefit the characterization of renal microstructure in preclinical studies.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] High Resolution Diffusion-Weighted Imaging Using Readout-Segmented Echo-Planar Imaging, Parallel Imaging and a Two-Dimensional Navigator-Based Reacquisition
    Porter, David A.
    Heidemann, Robin M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 468 - 475
  • [22] Value of Non Echo-Planar Diffusion-Weighted Magnetic Resonance Imaging in the Detection of Middle Ear Cholesteatoma
    Nagai, Noriaki
    Tono, Tetsuya
    Matsuda, Keiji
    Toyama, Katsuhiro
    Kawano, Hirokazu
    Kodama, Takao
    MEDITERRANEAN JOURNAL OF OTOLOGY, 2008, 4 (03): : 197 - 202
  • [23] A flexible two-dimensional phase correction for interleaved echo-planar imaging reconstruction
    Liu, HY
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) : 6846 - 6848
  • [24] Flexible two-dimensional phase correction for interleaved echo-planar imaging reconstruction
    Liu, Haiying
    Journal of Applied Physics, 1998, 83 (11 pt 2):
  • [25] The Evaluation of Zoomed Echo-Planar Diffusion-Weighted Magnetic Resonance Imaging With Two-dimensional Spatial-Selective Radiofrequency Excitation Pulses in Patients With Hilar Cholangiocarcinoma
    Liu, Jingjing
    Huang, Mengyue
    Ren, Yanan
    Xu, Man
    Li, Yinhua
    Cheng, Jingliang
    Zhu, Jinxia
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [26] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Takatsu, Yasuo
    Yamamura, Kenichiro
    Yamatani, Yuya
    Takahashi, Daisuke
    Yoshida, Rei
    Asahara, Masaki
    Honda, Michitaka
    Miyati, Tosiaki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 89 - 99
  • [27] High resolution diffusion tensor imaging using interleaved echo-planar imaging
    Bammer, R
    Augustin, M
    Seifert, T
    Strasser-Fuchs, S
    Stollberger, R
    Wach, P
    Hartung, HP
    Fazekas, F
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 2 - 11
  • [28] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Yasuo Takatsu
    Kenichiro Yamamura
    Yuya Yamatani
    Daisuke Takahashi
    Rei Yoshida
    Masaki Asahara
    Michitaka Honda
    Tosiaki Miyati
    Radiological Physics and Technology, 2022, 15 : 89 - 99
  • [29] Free-breathing echo-planar imaging based diffusion-weighted magnetic resonance imaging of the liver with prospective acquisition correction
    Asbach, Patrick
    Hein, Patrick A.
    Stemmer, Alto
    Wagner, Moritz
    Huppertz, Alexander
    Hamm, Bernd
    Taupitz, Matthias
    Klessen, Christian
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (03) : 372 - 378
  • [30] Characterization of focal liver lesions with diffusion-weighted echo-planar imaging
    Laghi, A
    Pavone, P
    Catalano, C
    Panebianco, V
    Fabiano, S
    Baeli, I
    Passariello, R
    HEPATOLOGY, 1999, 30 (04) : 282A - 282A