Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis

被引:30
|
作者
Shehata, Mohamed S. A. [1 ]
Aboelnas, Mohamed M. [2 ]
Abdulkarim, Ali N. [2 ]
Abdallah, Ahmed R. [3 ]
Ahmed, Hussien [1 ]
Holton, James [4 ]
Consigliere, Paolo [5 ]
Narvani, Ali A. [6 ]
Sallam, Asser A. [7 ]
Wimhurst, James A. [8 ]
Imam, Mohamed A. [7 ,8 ]
机构
[1] Zagazig Univ, Fac Med, Zagazig, Egypt
[2] Cairo Univ, Fac Med, Cairo, Egypt
[3] Mansoura Univ, Fac Med, Mansoura, Egypt
[4] Oxford Univ Hosp, Oxford, England
[5] St George Trauma Ctr, London, England
[6] St Peters Hosp, Rowley Bristow Orthopaed Ctr, Chertsey, England
[7] Suez Canal Univ Hosp, Dept Orthoped Surg & Trauma, Kilo 4-5 Ring Rd, Ismailia 41111, Egypt
[8] Univ East Anglia, Norfolk & Norwich Univ Hosp, Norwich, Norfolk, England
关键词
Femoral neck fractures; Internal fixation; Sliding hip screws; Cancellous screws; MULTIPLE CANNULATED SCREWS; INTERNAL-FIXATION; DYNAMIC HIP; OPERATIVE MANAGEMENT; DISPLACED FRACTURES; RANDOMIZED TRIAL; ELDERLY-PATIENTS; ARTHROPLASTY; PLATE; FEMUR;
D O I
10.1007/s00590-019-02460-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeBoth sliding hip screws (SHS) and cancellous screws are used in the surgical management of intracapsular femoral neck fracture. However, there is paucity of information as to which is the superior treatment modality. We performed this systematic review and meta-analysis study to compare the clinical outcomes of SHS and cancellous screws for the treatment of femoral neck fractures in adult patients.MethodsWe searched PubMed, Scopus, Web of Science, and Cochrane CENTRAL, up to December 2017. Randomized controlled trials (RCTs) directly comparing the clinical outcomes of SHS and cancellous screws for femoral neck fractures were retrieved with no language or publication year restrictions. Data retrieved included operative details, nonunion rate, avascular necrosis, reoperation, infection and mortality, hip pain, functional hip scores, and medical complications. These were pooled as risk ratio or mean difference (MD) with their corresponding 95% confidence interval (CI). Heterogeneity was assessed by Chi-square test.ResultsTen RCTs involving 1934 patients were included in the final analysis. The pooled estimate showed that the SHS group was associated with more intraoperative blood loss (MD=110.01 ml, 95% CI [52.42, 167.60], p=0.00002) than the cancellous screws. There was no significant difference in terms of operative time, postoperative hip function, nonunion, avascular necrosis, reoperation rate, infection, fracture healing, hip pain, medical complications, and mortality rate.ConclusionBased on our study, the cancellous screws group was associated with less intraoperative blood loss in comparison with the SHS group. No other significant differences were found between the two interventions.
引用
收藏
页码:1383 / 1393
页数:11
相关论文
共 50 条
  • [21] Reoperation for sliding hip screws vs cannulated cancellous screws in femoral neck fractures: A study from the Danish Fracture Database Collaborators
    Viberg, Bjarke
    Barat, Siar
    Rotwitt, Lars
    Gundtoft, Per Hviid
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (11): : 3805 - 3809
  • [22] Femoral neck system versus cannulated screws for fixation of femoral neck fracture in young adults: a systematic review and meta-analysis
    Lu, Yao
    Huang, Zhilong
    Xu, Yibo
    Huang, Qiang
    Ren, Cheng
    Li, Ming
    Li, Zhong
    Sun, Liang
    Xue, Hanzhong
    Zhang, Kun
    Wang, Qian
    Ma, Teng
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (08): : 5480 - +
  • [23] Comparison of young femoral neck fractures treated by femoral neck system, multiple cancellous screws and dynamic hip screws: a retrospectively comparison study
    Leyi Cai
    Wenhao Zheng
    Chunhui Chen
    Wei Hu
    Hua Chen
    Te Wang
    BMC Musculoskeletal Disorders, 25
  • [24] Comparison of young femoral neck fractures treated by femoral neck system, multiple cancellous screws and dynamic hip screws: a retrospectively comparison study
    Cai, Leyi
    Zheng, Wenhao
    Chen, Chunhui
    Hu, Wei
    Chen, Hua
    Wang, Te
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [25] SLIDING SCREW PLATE VERSUS 4 ASIF CANCELLOUS BONE SCREWS IN THE TREATMENT OF DISPLACED FEMORAL-NECK FRACTURES
    MADSEN, F
    LINDE, F
    ANDERSEN, E
    BIRKE, H
    HVASS, I
    POULSEN, TD
    ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (06): : 598 - 599
  • [26] COMPRESSION HIP SCREW VERSUS VONBAHR SCREWS IN FEMORAL-NECK FRACTURES
    LANGELAND, N
    ENGESAETER, LB
    ASSERSON, O
    MOLSTER, A
    GJERDET, NR
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 687 - 688
  • [27] Fixation with cancellous screws and fibular strut grafts for neglected femoral neck fractures
    Pal, Chandra Prakash
    Kumar, Binod
    Dinkar, Karuna Shankar
    Singh, Pulkesh
    Kumar, Harish
    Goyal, R. K.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (02): : 181 - 185
  • [28] Cannulated screws versus dynamic hip screw versus hemiarthroplasty versus total hip arthroplasty in patients with displaced and non-displaced femoral neck fractures: a systematic review and frequentist network meta-analysis of 5703 patients
    Nikolai Ramadanov
    Katarzyna Jóźwiak
    Michael Hauptmann
    Philip Lazaru
    Polina Marinova-Kichikova
    Dobromir Dimitrov
    Roland Becker
    Journal of Orthopaedic Surgery and Research, 18
  • [29] TREATMENT OF FEMORAL-NECK FRACTURES BY 4 COMPRESSING AO CANCELLOUS SCREWS
    PAABY, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 1974, 45 (05): : 796 - 796
  • [30] Fixation with cancellous screws and fibular strut grafts for neglected femoral neck fractures
    Upadhyay, Sachin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 446 - 446