Patient-Specific Atrium Models for Training and Pre-Procedure Surgical Planning

被引:3
|
作者
Laing, Justin [1 ]
Moore, John [2 ]
Bainbridge, Daniel [3 ]
Drangova, Maria [1 ,2 ]
Peters, Terry [1 ,2 ]
机构
[1] Western Univ, Dept Biomed Engn, 1151 Richmond St, London, ON N6A 3K7, Canada
[2] Robarts Res Inst, 1151 Richmond St North, London, ON N6A 5B7, Canada
[3] Western Univ, Dept Anesthesiol, 1151 Richmond St, London, ON N6A 3K7, Canada
来源
MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2017年 / 10135卷
关键词
Patient-Specific; 3D printing; Molding; Atria; Surgical Planning; Minimally Invasive; Cardiac; ULTRASOUND;
D O I
10.1117/12.2249693
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Minimally invasive cardiac procedures requiring a trans-septal puncture such as atrial ablation and MitraClip r mitral valve repair are becoming increasingly common. These procedures are performed on the beating heart, and require clinicians to rely on image-guided techniques. For cases of complex or diseased anatomy, in which fluoroscopic and echocardiography images can be difficult to interpret, clinicians may benefit from patient-specific atrial models that can be used for training, surgical planning, and the validation of new devices and guidance techniques. Computed tomography (CT) images of a patient's heart were segmented and used to generate geometric models to create a patient-specific atrial phantom. Using rapid prototyping, the geometric models were converted into physical representations and used to build a mold. The atria were then molded using tissue-mimicking materials and imaged using CT. The resulting images were segmented and used to generate a point cloud data set that could be registered to the original patient data. The absolute distance of the two point clouds was compared and evaluated to determine the model's accuracy. The result when comparing the molded model point cloud to the original data set, resulted in a maximum Euclidean distance error of 4.5 mm, an average error of 0.5 mm and a standard deviation of 0.6 mm. Using our workflow for creating atrial models, potential complications, particularly for complex repairs, may be accounted for in pre-operative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Patient-specific three-dimensional printing for pre-surgical planning in hepatocellular carcinoma treatment
    Perica, Elizabeth
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (06) : 668 - +
  • [22] Patient-specific treatment planning of electrochemotherapy: Procedure design and possible pitfalls
    Pavliha, Denis
    Kos, Bor
    Zupanic, Anze
    Marcan, Marija
    Sersa, Gregor
    Miklavcic, Damijan
    BIOELECTROCHEMISTRY, 2012, 87 : 265 - 273
  • [23] Patient-specific Surgical Simulation
    Luc Soler
    Jacques Marescaux
    World Journal of Surgery, 2008, 32 : 208 - 212
  • [24] Patient-specific surgical simulation
    Soler, Luc
    Marescaux, Jacques
    WORLD JOURNAL OF SURGERY, 2008, 32 (02) : 208 - 212
  • [25] A computational framework for patient-specific surgical planning of type 1 thyroplasty
    Movahhedi, Mohammadreza
    Geng, Biao
    Xue, Qian
    Zheng, Xudong
    JASA EXPRESS LETTERS, 2021, 1 (12):
  • [26] Virtual Surgical Planning and Patient-Specific Implants in Facial Feminization Surgery
    Alperovich, Michael
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2022, 24 : S20 - S23
  • [27] Patient-specific model of arterial circulation for surgical planning of vascular access
    Passera, Katia
    Manini, Simone
    Antiga, Luca
    Remuzzi, Andrea
    JOURNAL OF VASCULAR ACCESS, 2013, 14 (02): : 180 - 192
  • [28] Application of virtual endoscopy to the patient-specific planning of endovascular surgical procedures
    Acosta, O
    Haigron, P
    Lucas, A
    Bellemare, ME
    MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 58 - 69
  • [29] Surgical Planning and Patient-Specific Biomechanical Simulation for Tracheal Endoprostheses Interventions
    Gonzalez Ballester, Miguel A.
    Perez del Palomar, Amaya
    Lopez Villalobos, Jose Luis
    Lara Rodriguez, Laura
    Trabelsi, Olfa
    Perez, Frederic
    Ginel Canamaque, Angel
    Barrot Cortes, Emilia
    Rodriguez Panadero, Francisco
    Doblare Castellano, Manuel
    Herrero Jover, Javier
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT II, PROCEEDINGS, 2009, 5762 : 275 - +
  • [30] Evaluation of accuracy of virtual surgical planning for patient-specific pre-contoured plate in acetabular fracture fixation
    Maini, Lalit
    Verma, Tarun
    Sharma, Amit
    Sharma, Ankur
    Mishra, Abhishek
    Jha, Sunil
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (04) : 495 - 504